brinno MAS200 Motion Detector User Manual

June 12, 2024
brinno

Motion Detector
**MAS200 User Manual

**

Package Contents

  1. Door Knocker Casing
  2. Motion Sensor Unit (inside knocker casing)
  3. Receiver Unit
  4. Magnetic Wall Mount
  5.  Screwdriver
  6.  Battery Lock* (inside motion sensor unit)
  7. 1 CR2450 Battery (inside motion sensor unit)
  • Keep battery out of reach of children. Install battery lock to prevent children from swallowing battery.

Before You Start

Take motion sensor unit out of door knocker casing.

  1. Remove knocker ring.
  2. Open the front cover.brinno MAS200 Motion Detector - front cover
  3. Take out motion sensor unit.brinno MAS200 Motion Detector - motion

Device Parts

Receiver Unit:

brinno MAS200 Motion Detector - Receiver

  1. Connector
  2. LED Indicator

Motion Sensor Unit:

brinno MAS200 Motion Detector - Motion Sensor

  1. Motion Sensor Lens
  2. Battery Compartment
  3. Motion Sensor Pairing Channel Switch
  4. Pairing Button
  5. LED Indicator

Activate Motion Sensor

For Camera:

brinno MAS200 Motion Detector - Insert receiver For Motion Sensor Unit:

Open front cover.

Remove tab and engage battery to activate motionsensor. Wait 30 secs for the sensor to be auto paired. Motion sensor icon will appear on the camera LCD once activated. ****If you choose to set up a multiple motion sensors environment and purchase additional motion sensor units, please refer to Multiple Sensors Part below for full details.

Display Icons

  1. Connected sensors:
    The icon turns white to indicate the device is successfully connected to the sensor.

  2. Sensor in low battery:
    The icon turns red to alert battery dropping low.brinno MAS200 Motion
Detector - battery

Sensor Installation

Door Knocker Mode:
Insert motion sensor unit into door knocker casing included in the package. Portable Mode:
Hide motion sensor unit anywhere separately near your front door.brinno
MAS200 Motion Detector - Hide motion

Transmission/Detection

Transmission Distance:
32 ft (10m) between motion sensor unit and receiver unit inside the camera. When you choose Portable Mode, make sure the two units are within the transmission distance.brinno MAS200 Motion Detector -
distance Sensor Detection Area:
Detection angle: 90 degrees (horizontal).
Detection distance: 13 ft (4 m) (centerline).
(approx. 5 ft (1.5 m) on both sides of the centerline).

  1. brinno MAS200 Motion Detector - angleInsert receiver unit into camera.
  2. Turn the camera power on.
  3. Pair sensors.

Specifications

Model MAS200
 Detection Angle 90° (horizontal)
Detection Distance Centerline: 13 ft (4 m)

Side: 5 ft (1.5 m)
Transmission Distance
to Receiver| 32 ft (10 m)
Power Source| 1 CR2450 battery (included)
Battery Life| Approx. 28,000 triggers
Operating
Temperature| 32 F ~ 113 F (0C ~ 45C)
 Splash-proof| IPX4
Compatible Model| SHC1000, SHC1000W
Size (WxHxD)| Door knocker casing:
2.3″ x 3.8” x 1.1” ( 59 x 97 x  28 mm)
Motion sensor unit:
1.7″ x 2” x 0.5” ( 44 x 52 x 14  mm)
Receiver unit:
1.5″ x 1.1” x 0.2” ( 37 x 29 x 6 mm)
Weight| Door knocker casing:
1.3 oz ( 36 g)
Motion sensor unit:
0.7 oz ( 21 g) (without batteries)
Receiver unit:
0.2 oz ( 5.5 g)
Package Contents| Door knocker casing; Motion sensor unit (inside knocker casing); Receiver unit; Magnetic wall mount; Battery lock; Screwdriver; 1 CR2450 battery.

Pairing Channels

One camera supports up to 6 motion sensors. You make difierent channel combinations to identify each unique motion sensor.

Motion Sensor Pairing Channel Switch: Pairing Channel Combination:brinno
MAS200 Motion Detector - Pairing Channel C

Pin the pairing button for 4~6 secs. (place the motion sensor within 12 in (30cm)). On motion sensor, LED light fiashes blue. On receiver unit, LED light fiashes red. On camera screen, motion sensor icon appears.

  1. Motion Sensor takes around 30 secs to warm up after sensor pairing is done.
  2.  Run motion sensor test and make sure the camera is working properly.

Delete Sensor

  1. The screen displays all paired sensors.
    Press SHUTTER BUTTON to go to the DELETE SENSOR option.

  2. Select one sensor or all sensors to be deleted from the list.
    Press SHUTTER BUTTON to confrm deletion.

  3. Press SHUTTER BUTTON again to delete.

  4. Restart the camera. The selected sensor will be permanently deleted.

FCC
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT.
This equipment has been tested and found to comply with the limit s for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, theuser is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
  •  Consult the dealer or an experienced radio/TV technician for help.

CAUTION:
Any changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RF Radiation Exposure Statement:

  1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
  2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.15.19 Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference and
  2. this device must accept any interference received, including interference that may cause undesired operation of the device.

This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

RF Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Register @ nline
www.brinno.com/supporthegistration

For manuals in other languages, visit www.brinno.com/support

The product features, specifications sheets and instructions may difier from actual products. Please refer to Brinno oficial site for  the latest version of user manual.

Complles with
IMDA Standards
N4232-17
EN_A2 301-0116-01

References

Read User Manual Online (PDF format)