Solplanet ASW 5-12K H-T2/T3 Series Three Phase Hybrid Inverter Installation Guide

June 12, 2024
solplanet

Solplanet ASW 5-12K H-T2/T3 Series Three Phase Hybrid Inverter

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-
PRODUCT

Product Information

The ASW05kH/06kH/08kH/10kH/12kH-T2 ASW05kH/06kH/08kH/10kH/12kH-T2-O ASW08kH/10kH/12kH-T3 ASW08kH/10kH/12kH-T3-O is a three-phase hybrid inverter. It is designed and tested according to international safety requirements. The product operates at high voltage and current and should only be worked on by skilled and authorized electricians. It has been certified by TUV and complies with the requirements of EU directives. The product also has the Regulatory Compliance Mark (RCM) and complies with applicable Australian standards.

Product Usage Instructions

  1. Ensure that you have read the user manual for detailed instructions.
  2. For safety, always observe the following precautions:
    • Danger to life due to high voltages of the PV array or the battery. Do not reconnect before working on the product.
    • Danger to life due to electric shock when touching live components in backup mode. Take necessary precautions and avoid touching live components.
    • Danger to life due to fire or explosion when batteries are fully discharged. Ensure batteries are not fully discharged.
    • Danger to life due to burns caused by electric arcs through short-circuit currents. Avoid short-circuits.
    • Danger to life due to electric shock when touching live system components in case of a ground fault. Be cautious and avoid touching live system components.
    • Danger to life due to electric shock from destruction of the measuring device due to overvoltage. Ensure input voltage range is within the product’s voltage rating.
    • Risk of burns due to high temperature. Be cautious of hot surfaces.
    • Risk of injury due to weight of product. Handle with care due to its weight.
  3. Observe the symbols on the label:
    • Beware of a danger zone: Additional grounding may be required at the installation site.
    • Beware of high voltage and operating current: Only skilled and authorized electricians should work on the inverter.
    • Beware of hot surfaces: Avoid contact with the inverter during operation.
    • WEEE designation: Dispose of the product according to electronic waste disposal regulations.
    • CE marking: The product complies with EU directives.
    • Certification mark: The product has been tested and certified by TUV.
    • RCM (Regulatory Compliance Mark): The product complies with applicable Australian standards.
    • Capacitor discharge: Do not touch live parts for 5 minutes due to high voltages in the inverter.

For more detailed information and instructions, refer to the user manual available in PDF format at www.solplanet.net.

GENERAL INFORMATION

This quick installation guide does not replace the description in the user manual. The contents of this guide may be updated or revised due to product development. The information in this guide is subject to change without notice. The latest version of this document and the manual for installation, commissioning, configuration and decommissioning are to be found in PDF format at www.solplanet.net.

SAFETY

Intended use
The product is a transformerless hybrid inverter with 2 or 3 MPP trackers and a battery connection that feeds the direct current of the PV array into the connected battery or converts it to grid-compliant three-phase current and then feeds it into the utility grid. The product also can convert the direct current supplied by the battery into grid-compliant three-phase current. The product has a backup function that can continue to supply selected circuits with power from the battery or PV system in the event of a grid fault. The product is intended for indoor and outdoor applications. The product must only be connected with PV modules of protection class II (in accordance with IEC 61730, application class A). Do not connect any sources of energy other than PV modules to the product. The product is not equipped with an integrated transformer and therefore has no galvanic isolation. The product must not be operated with PV modules which require  functional grounding of either the positive or negative PV conductors. This can cause the product to be irreparably damaged. The product may be operated with PV modules with frames that require protective earthing. All components must remain within their permitted operating ranges and their installation requirements at all times. Use the product only in accordance with the information provided in the user manual and with the locally applicable standards and directives. Any other application may cause personal injury or damage to property. The product must only be operated in connection with an intrinsically safe lithium-ion battery approved by AISWEI. The entire battery voltage range must be completely within the permissible input voltage range of the product. The product must only be used in countries for which it is approved by AISWEI and the grid operator. The type label must be permanently attached to the product and must be in a legible condition. This document does not replace any regional, state, provincial, federal or national laws, regulations or standards that apply to the installation, electrical safety and use of the product.
Important safety instructions
The product has been designed and tested strictly according to the international safety requirements. As with all electrical or electronical devices, there are residual risks despite careful construction. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times.

DANGER
Danger to life due to high voltages of the PV array or the battery! The DC cables connected to the battery or the PV array may be live. Touching the DC conductors or the live components can cause to lethal electric shocks. If you disconnect the DC connectors from the product under load, an electric arc may occur leading to electric shock and burns.

  • Do not touch non-insulated cable ends.
  • Do not touch the DC conductors.
  • Do not touch any live components of the product.
  • Do not open the product.
  • Observe all safety information of the battery manufacturer.
  • All work on the product must only be carried out by qualified personnel who have read and fully understood all safety information contained in this document and the user manual.
  • Disconnect the product from all voltage and energy sources and ensure it cannot be reconnected before working on the product.
  • Wear suitable personal protective equipment for all work on the product.

DANGER
Danger to life due to electric shock when touching live components in backup mode!Even if the AC breaker and the PV switch of the inverter are disconnected, the parts of the system may still be live when the battery is switched on due to backup mode.

  • Do not open the product.
  • Disconnect the product from all voltage and energy sources and ensure it can not be reconnected before working on the product.

DANGER
Danger to life due to fire or explosion when batteries are fully discharged! A fire may occur due to incorrect charging of fully discharged batteries. This can result in death or serious injury.

  • Make sure that the battery is not fully discharged before commissioning the system.
  • Contact the battery manufacturer for further proceedings if the battery is fully discharged.

DANGER
Danger to life due to burns caused by electric arcs through short-circuit currents! Short-circuit currents in the battery can cause heat accumulation and electric arcs if the battery is short circuited or wrongly installed. Heat accumulation and electric arcs may result in lethal injuries due to burns.

  • Disconnect the battery from all voltages sources prior to performing any work on the battery.
  • Only use properly insulated tools to prevent accidental electric shock or short circuits during installation.
  • Observe all safety information of the battery manufacturer.

DANGER
Danger to life due to electric shock when touching live system components in case of a ground fault! If a ground fault occurs, parts of the system may still be live. Touching live parts and cables may result in death or lethal injuries due to electric shock.

  • Disconnect the product from voltage and energy sources and ensure it cannot be reconnected before working on the device.
  • Only touch the cables of the PV modules on their insulation.
  • Do not touch any parts of the substructure or frame of the PV array.
  • Do not connect PV strings with ground faults to the product.

WARNING

  • Danger to life due to electric shock from destruction of the measuring device due to overvoltage!
  • Overvoltage can damage a measuring device and result in voltage being present in the enclosure of the measuring device. Touching the live enclosure of the measuring device results in death or lethal injuries due to electric shock.
  • Only use measuring devices with the measurement span higher than the DC input voltage range equal to or higher than the voltage rating of the product.

CAUTION
Risk of burns due to high temperature. Some parts of the enclosure can become hot during operation.

  • During operation, do not touch any parts other than the enclosure lid of the product.

CAUTION
Risk of injury due to weight of product . Injuries may result if the product is lifted incorrectly or dropped while being transported or mounted.

  • Transport and lift the product carefully. Take the weight of the product into account.
  • Wear suitable personal protective equipment for all work on the product.

Symbols on the label

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(2\)

  • Beware of a danger zone!
    This symbol indicates that the product must be additionally grounded if additional grounding or equipotential bonding is required at the installation site.

  • Beware of high voltage and operating current!
    The inverter operates at high voltage and current. Work on the inverter must only be carried out by skilled and authorized electricians.

  • Beware of hot surfaces!
    The inverter can get hot during operation. Avoid contact during operation.

  • WEEE designation
    Do not dispose of the product together with the household waste but in accordance with the disposal regulations for electronic waste applicable at the installation site.

  • CE marking
    The product complies with the requirements of the applicable EU directives.

  • Certification mark
    The product has been tested by TUV and got the quality certification mark.

  • RCM (Regulatory Compliance Mark)
    The product complies with the requirements of the applicable Australian standards.

  • Capacitor discharge
    Danger to life due to high voltages in the inverter. Do not touch live parts for 5 minutes after disconnection from the power sources.

  • Observe the documentation
    Observe all documentation supplied with the product.

SYSTEM WIRING DIAGRAM

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(3\) Solplanet-
ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(4\)

EU DECLARATION OF CONFORMITY

Within the scope of the EU directives Radio Equipment Directive 2014/53/EU (L 153/62-106. May 22. 2014) (RED) Restriction of the use of certain hazardous substances 2011/65/EU (L 174/88, June 8, 2011) and 2015/863/EU (L 137/10, March 31,2015) (RoHS) AISWEI Technology Co., Ltd. confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the above mentioned directives. The entire EU Declaration of Conformity can be found at www.solplanet.net.

OVERVIEW

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-
FIG-1 \(5\)Solplanet-
ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(24\)

SCOPE OF DELIVERY

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-
Inverter-FIG-1 \(6\)

MOUNTING ENVIRONMENT

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(7\)DIMENSIONS Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(8\)MOUNTING Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(9\)Solplanet-
ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(10\)

SECOND PROTECTIVE GROUNDING

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(11\)

AC CONNECTION

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-
Inverter-FIG-1 \(12\)

BACKUP LOAD CONNECTION

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-
Hybrid-Inverter-FIG-1 \(13\)

PV CONNECTION

TYPE 1 – Phoenix ContactSolplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-
Hybrid-Inverter-FIG-1 \(14\) TYPE 2Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(15\)

BATTERY CONNECTION

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(16\)

COMMUNICATION SETUP

15.1 Communication connectionSolplanet-ASW-5-12K-H-T2-T3-Series-Three-
Phase-Hybrid-Inverter-FIG-1 \(17\)

Object

|

Description

|

Terminal

| PIN definition
---|---|---|---
1| 2| 3| 4| 5| 6| 7| 8
RJ45-3| Monitor| COM2| RS485A| RS485B| GND| X| X| X| RS485A| RS485B
RJ45-4| BMS| COM5| X| GND| X| CANAH| CANAL| X| RS485A| RS485B

Object         Description Terminal

| PIN Definition
---|---
1| 2| 3| 4| 5| 6

Terminal-1

|

DO1/DO2

|

4pin

| Multifunction Relay 1| Multifunction Relay 2|
B| A| B| A

Terminal-2

|

\

|

6pin

| Smart Meter| PT100 Temperture Sensor| UFR Device
RS485A| RS485B| Positive| Negative| Positive| Negative

Terminal-3

|

DI*4/DRM0

|

6pin

| Ripple Control Receiver Device| DRMS Device
DI_4| DI_3| DI_2| DI_1| REF GEN/0| COM LOAD/0

or GND

Terminal-4

|

CT

|

6pin

| Current Transformer L1(U)| Current Transformer L2(V)| Current Transformer L3(W)
Red| Black| Red| Black| Red| Black

Solplanet-ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(18\)Solplanet-
ASW-5-12K-H-T2-T3-Series-Three-Phase-Hybrid-Inverter-FIG-1
\(19\)

Current Transformer connection (optional)

Solplanet-ASW-5-12K-H-T2-T3
-Series-Three-Phase-Hybrid-Inverter-FIG-1 \(20\)

Smart meter connection (optional)

Solplanet-ASW-5-12K-H-T2-T3-Series-
Three-Phase-Hybrid-Inverter-FIG-1 \(21\)Ai-Dongle connectionSolplanet-ASW-5-12K-H-T2-T3
-Series-Three-Phase-Hybrid-Inverter-FIG-1 \(22\)

CONTACT

Please contact our Service Department if you have any technical questions about our products. The following information is needed to provide necessary assistance:

  • Inverter model
  • Inverter serial number
  • Photovoltaic module model
  • Photovoltaic modules number and strings number connected to each MPPT
  • Fault code
  • Installation location

EMEA

APAC

LATAM

Taiwan

QG0049_ASW05-12KH-T2-T3_EN_540-300254-01_V02_0623  AISWEI Technology CO., Ltd

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

solplanet User Manuals

Related Manuals