Product Information

The product is a safe with the model name “SUPRA”. It has a lock mechanism and comes with an emergency key. The safe can be opened using a standard code or a master code, both consisting of 3 to 6 digits. The safe also has the option to be opened using an external battery. The safe requires 4 AA batteries for operation.

Product Usage Instructions

  • Battery Installation

    • Open the door of the safe.
    • Remove the plastic cover located behind the door.
    • Insert 4 new 1.5V AA batteries into the battery compartment.
  • Programming the Opening Codes

    • The safe allows the programming of two secret opening codes: a standard code and a master code.

    • The initial standard code is 000000, and the initial master code is [not provided].
      To program the standard code

    • Ensure that the safe is open.

    • Use the button to enter the desired code.

    • Verify that the new code works correctly by opening the safe (refer to section 3, “Opening the Safe”).

    • Repeat the process for programming the master code.


  • Opening the Safe:

    • Enter one of the active opening codes.
    • Rotate the key clockwise within 5 seconds to open the safe. – If an incorrect code is entered, an error will be displayed on the screen.
  • Closing the Safe:

    • Simply rotate the key counterclockwise to close the safe.
  • Opening with the Emergency Key:

    • [Instructions not provided in the text extract.] ****
  • Opening with an External Battery:

    •  [Instructions not provided in the text extract.] ****
  • Other Control Elements:

    • [No specific instructions provided in the text extract.] ****
  • Maintenance
    Periodically (every 6 months), check the condition of the battery compartment for signs of rust, solation, etc. – Lubricate the moving mechanical parts, such as bolts and locks. Please note that the provided text extract does not contain complete instructions for all functions of the safe. For detailed instructions on using the emergency key or opening with an external battery, refer to the complete user manual.

IMPORTANT:
The first opening of the safe you must use the emergency key:

  • Insert the emergency key with the red point and turn it clockwise.

NOTE: Do not store the emergency key inside the safe

BATTERY INSTALLATION

Open the door, remove the plastic cover located behind the door and place 4 new 1,5V AA batteries.

PROGRAMMING THE OPENING CODES

This safe allows to program two secret opening codes–one standard and one master, from 3 to 6 digits each.
The initial standard code is 000000 and the initial master code is 888888. For your security, it´s important that you change them and configure the codes you desire.
During the process, use the button to delete the last digit entered.
Programming the standard code (the safe must be open):

  • Press and the button. The screen will display SELECT.
  • Press the button. The screen will display SET.
  • Enter your code (3 to 6 digits) and press the button.

The screen will display DONE.
With the door open, verify that the new code operates correctly (see section 3, opening the safe).
Programming the master code (the safe may be open or closed):

  • Press and the button. The screen will display  SELECT.
  • Press the button. The screen will display OLD.
  • Enter the current master code (888888 the first time) and press the button. The screen will display SET (if the code entered is incorrect, it will display ERROR).
  • Enter the new master code (3 to 6 digits) and press the button. The screen will display REPEAT.
  • Enter the new master code again and press the button. The screen will display DONE (if the code entered is not the same both times, the screen will display ERROR).

OPENING THE SAFE

Enter either of the two active opening codes, then turn the key in clockwise direction to open the door within 5 seconds.
If an incorrect code is entered, the screen will display ERROR1, for a second incorrect attempt it will display ERROR2, and for a third incorrect attempt it will display ERROR3 and the system will remain blocked for 5 minutes, indicating by blinking HOLD 5… HOLD 4… etc. During this time, the keypad cannot be used.

CLOSING THE SAFE
Just turn the key in anticlockwise direction to close the door.

OPENING WITH THE EMERGENCY KEY

If you do not have the opening codes, or if the batteries have run out and an external battery is not available, you can open the safe using the emergency key.
For this, access the emergency lock. Introduce the emergency key provided with these instructions and turn it. The safe will open.

Note: In case of an emergency opening due to a wrong code, the emergency key opens the door but does not unblock the electronic system, you must wait for the deadbolt time to expire.

OPENING WITH AN EXTERNAL BATTERY

If the batteries have run out, you can use the safe by placing a 9V battery in the power supply located to the right of the keypad. Once the safe is open, replace the batteries.

OTHER CONTROL ELEMENTS

  • SCREEN CONTROL: To configure the screen so it does not display the digits that are entered, press the button and then the 3 button. If you would like the screen to display what you enter, press the 3 button again.
  • SOUND CONTROL: To use the safe in silent mode, press the button and then the 6 button. If you would like the safe to emit sounds again, press the 6 button again.
  • BATTERY STATUS CONTROL: If you would like to know whether the batteries are sufficiently charged, press the button while the safe is closed. If the batteries are fine, the screen will display HI-BAT, and if they are not, the message will be LO-BAT. In that case, you should replace the batteries with new ones.
    In any case, if the batteries are not sufficiently charged, the system will warn you of this when the safe is opened and closed by displaying the OPEN LO- BAT or CLOSE LO-BAT messages on the screen, respectively.

NOTE: During the battery change process, the safe will not forget the codes that have been entered.

MAINTENANCE

Check the condition of the battery compartment on a regular basis (every 6 months) to identify any possible signs of rust, sulphation, etc.
Grease/oil any mechanical moving parts, such as locks and bolts.

GUARANTEE CERTIFICATE

The safe is guaranteed for a period of 24 months from the date of its purchase, as established by the Law 23/2003 dated July 10th on Guarantees in the Sale of Consumer Goods.
ABSS accepts the responsibility for lacks of approval declared within a period of two years in the event of any manufacturing fault which affects the functioning of the safe from the date of its delivery, according to the law. As from the first 12 months, the buyer must prove that the non-conformity already existed at the moment he received the safe.
The faults produced as a result of an improper use or installation, an excess of humidity or salinity, water or cement filtrations, force, the handling of the devices by non-authorized persons, disasters, impacts and falls are excluded from the guarantee.
The repair or substitution of any part due to a fault implies a 6-month extension to the guarantee of the part repaired or substituted. ABSS will accept the responsibility for the non-conformities that caused this repair when the same factory faults that caused the first repair are repeated.

IDENTITY DETAILS

  • Name of the supplier ………………………………………………………………………………………………………………………………….
  • Date of sale …………………………………………………………………………………………………………………………………………….
  • Name of purchaser ……………………………………………………………………………………………………………………………………
  • Address of purchaser ……………………………………………………………………………………………………………………………………

IDENTIFYING DETAILS OF THE SALE

  • Model …………………………………………………………………………………………………………………………………………………….
  • Series number ………………………………………………………………………………………………………………………………………….

IMPORTANT:

  • These details must be completed as clearly as possible and without delay by the supplier, who will stamp and sign on behalf of his company in the place indicated.
  • The certificate remains in the possession of the purchaser.
  • The purchaser must keep the RECEIPT for the purchase of the safe, together with the GUARANTEE CERTIFICATE to be able to accredit the date of purchase. Both documents are necessary to use the guarantee.

Arregui
Pol. Industrial Ubegun. 3B.
20809 Aia-Orio. Gipuzkoa
(SPAIN)
arregui@arregui.es
www.arregui.es

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals