ARREGUI SUA Class Electronic Surface Safe Instruction Manual
- June 9, 2024
- ARREGUI
Table of Contents
- vSUA Class Electronic Surface Safe
- INSTALLING/REPLACING THE BATTERY
- OPENING AND CLOSING THE SAFE
- PROGRAMMING THE OPENING CODES (USER AND MASTER CODES)
- DUAL CODE
- OPENING DELAY TIME (OD) AND THE OPENING WINDOW (OW)
- TURN THE SOUND ON/OFF
- LOW BATTERY INDICATOR
- MAINTENANCE
- KEY COPY
- GUARANTEE CERTIFICATE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Class Electronic Surface Safe
Instruction Manual
Electronic Safe.
Scan the QR code to access the instructions or download them from our website.
vSUA Class Electronic Surface Safe
Note: For models that open with a key, it is necessary to place it in the
open position in order for the safe to open when you enter the codes.
It is strongly recommended to change the settings of the lock with the door
opened.
INSTALLING/REPLACING THE BATTERY
-
The battery is on the inside of the door. Depending on the safe model, the battery may be inside the battery compartment of the lock (picture a) or in a special removable battery box (picture b).
-
Remove the cover from the battery compartment of the lock or take the box out.
-
Install a new battery (9V).
-
Put the cover back on.
HOW TO OPEN THE SAFE WHEN THE BATTERY IS DEAD
-
Get a new battery (9V).
-
Press the new battery into place on the emergency power contacts and secure it in this position.
-
Make sure the battery does not come into contact with the metal parts of the lock.
-
Enter a valid opening code on the keypad.
-
Take out the battery, open the door to the safe and replace the dead battery.
OPENING AND CLOSING THE SAFE
IMPORTANT: For SUA electronic key-operated safe models, the key must be inserted into the lock and turned clockwise before pressing ON and entering the opening code.
- Press “ON”. The safe will beep and the light will turn green.
- Enter the master code (123456 by default) or the 6-to-8digit user code (this is not configured by default; to do so, see “Programming the User Code).
- Press “ENTER”. Once the light turns green you have approximately 5 seconds to turn the handle clockwise and open the safe.
TO CLOSE THE SAFE , simply close the door and turn the handle
anticlockwise.
If you enter an incorrect code 3 times in a row, the safe will be blocked for
5 minutes. When this occurs, the light flashes red.
PROGRAMMING THE OPENING CODES (USER AND MASTER CODES)
2.1. CHANGING THE MASTER CODE
- Press «ON».
- Press «ENTER».
- Pulse «1».
- Press «ENTER».
- Enter the current master code and press “ENTER” (when programming for the first time, the default master code is 123456).
- Enter the new master code (minimum of 6 and maximum of 8 digits) and press “ENTER”.
- Enter the new master code again and press “ENTER”.
- To check the new master code, press: “ON” > New master code > “ENTER”.
If the process has been completed successfully, the safe will beep twice and the light will turn green.
If the process has not been completed successfully, the safe will beep a long beep and the light will turn red. In this case, wait 10 seconds and then start the process again from the beginning.
2.2. PROGRAMMING THE USER CODE (USING THE MASTER CODE)
IMPORTANT: it is possible to program up to 9 codes User Codes. It is necessary to assign each user 1 digit from 1 to 9, which we will call “User number”.
- Press «ON».
- Press «ENTER».
- Pulse «2».
- Press «ENTER».
- Enter the user number (1 digit from 1 to 9) > “ENTER” > master code > “ENTER”.
- Enter the new user code (6 to 8 digits) > “ENTER”.
- Enter the new user code (6 to 8 digits) again > “ENTER”.
To check the new user code, press: “ON” > New user code >“ENTER” and the safe
should open.
To program different users remember that you must assign each of them a user
number (one digit 1 to 9), which cannot be repeated.
2.3. CHANGING THE USER CODE (WITHOUT THE MASTER CODE)
- Press «ON».
- Press «ENTER».
- Pulse «3».
- Press «ENTER».
- Enter the user number (1 digit from 1 to 9) / «ENTER» / 6 to 8 digit user code / «ENTER».
- Enter the new user code and press “ENTER”.
- Enter the new user code again and press “ENTER”.
To check the new user code, press: “ON” > New user code > “ENTER”.
2.4. ERASING THE USER CODE
- Press «ON».
- Press «ENTER».
- Pulse «0».
- Press «ENTER».
- Enter the user number (1 digit from 1 to 9) / «ENTER» / master code / «ENTER».
The user code will be erased and the master code will be kept.
DUAL CODE
When using the dual code system it is necessary to insert the master code and the user code to open the box. To enable this function both codes must be previously programmed.
3.1. PROGRAMACIÓN DE CÓDIGO DUAL
- Press “ON”.
- Press “ENTER”.
- Press “7”.
- Press “ENTER”.
- Enter the current master code and press “ENTER”
3.2.OPENING THE SAFE WITH THE DUAL CODE FUNCTION
- Press “ON” ( The safe will beep twice) .
- Enter the number of the 1st user (1 number between 1 and 9) / “ENTER” / 6- to 8-digit user code/ “ENTER”.
- Enter the number of the 2nd user authorised for dual-mode opening (1 number between 1 and 9) / “ENTER” / code of 2nd user / “ENTER”.
- After entering the code for the 1st user, you have 1 minute to enter the code for the 2nd user.
The safe will emit short beeps and flashes of green light during these 60 seconds at 5-second intervals.
3.3. DEACTIVATING THE DUAL CODE
- Press «ON».
- Press «ENTER».
- Press “8”.
- Press “ENTER”.
- Enter the current master code and press “ENTER”.
OPENING DELAY TIME (OD) AND THE OPENING WINDOW (OW)
The opening delay time function (OD) refers to the amount of time that passes
between the code is entered and the door is unlocked (green light).
The opening window (OW) is the period during which you can open the door once
the OD has passed. This is the same when opening with both the master and the
user code.
4.1. PROGRAMMING THE OPENING DELAY TIME (OD) AND THE OPENING WINDOW (OW)
- Press “ON”.
- Press “ENTER”.
- Press “6”.
- Press “ENTER”.
- Enter the current master code and press “ENTER”.
- Enter a 2-digit number for the opening delay, OD (01-99 minutes), and a 1-digit number for the opening window, OW (1-9 minutes).
- Press “ENTER”.
For example, if you enter 092, the OD will be 9 minutes (how long you must wait before you can open the safe) and the OW will be 2 minutes (time available to open the safe).
4.2.OPENING WITH OD AND OW PROGRAMMED
- Press ON
- Enter a user code or the current master code
- Press ENTER
- OD automatically starts: red light flashes every 5 seconds.
- OD ends: beep.
- OW automatically starts: green light flashes and beep every 5 seconds.
- Enter the opening code again during the OW and press «ENTER». Once the light turns green you have approximately 5 seconds to turn the handle clockwise and open the safe.
You can interrupt this function by pressing “ENTER” during the OD period. The whole sequence must be repeated.
4.3 CANCELLING THE PROGRAMMED OD/OW
- Press “ON”.
- Press “ENTER”.
- Press “6”.
- Press «ENTER».
- Enter the valid user or master code and press “ENTER”.
- Enter “000” (“00”as the 2 digits for the OD period (opening delay time) and “0” as the digit for the OW (opening window).
- Press “ENTER”.
For example, enter “000” to cancel the OD and OW.
TURN THE SOUND ON/OFF
- Press “ON”.
- Press “ENTER”.
- Press “5”.
- Press “ENTER”.
- Enter the current master code and press “ENTER”.
LOW BATTERY INDICATOR
When the battery is low, the light turns red and the safe will beep 5 times. In this case, it is necessary to change the batteries.
MAINTENANCE
Periodically (every 6 months) check the condition of the battery compartment to detect possible signs of rust, sulphation, etc. Grease/oil any mechanical moving parts, such as locks and bolts.
KEY COPY
In the case of a safe with a key, if you lose the key you may request a copy by indicating the serial number of your safe, which is located on the bottom right of the door.
V ANCHOR (ANCHOR BOLT)
Drill a hole in accordance with the table.
Use a hammer to install the anchor.
Screw the anchor into the wall until it is steady.
The V anchor (anchor bolt) is designed to install medium-to-heavy items using
a through hole. V anchors can be used with concrete, natural stone and dense
bricks (with no holes). When adjusting the V anchor (anchor bolt), remember
that the distance between the installation points and the end of the base have
a significant impact on the load. If
these distances are reduced, the load is also reduced.
Installation of the anchor
Parameters for installing V anchors
Dimensions of the anchor (in mm)| Length of the anchor (L)|
Diameter of the drill bit
(D)| Minimum depth of the perforation (M)| Minimum depth of the
installation (M)
---|---|---|---|---
12/140| 140| 12| 110| 80
D – Diameter of the drill bit
L – Thickness of the material installed
M – Minimum depth of the perforation
H – Minimum depth of the anchor installation
GUARANTEE CERTIFICATE
This product is guaranteed for the periods stipulated in the Law on
Guarantees. ABSS is liable for any non-conformities that may occur as a result
of a manufacturing fault that affects the performance of the product within
the legally prescribed timeframe.
After this period, the consumer will have to prove that the non-conformity
already existed at the time of receiving the product.
The warranty does not cover faults caused as a result of improper use or
installation, excessive moisture or salinity, water or cement leakage, force,
unauthorised manipulation of the mechanisms, catastrophic events, knocks or
falls.
The repair or replacement of any faulty part will involve an extension of the
guarantee of the repaired or replacement part, in accordance with the
provisions of the Law on Guarantees.
IDENTITY DETAILS
Name of the supplier ……………………………………….
Date of sale ……………………………………………………..
Name of purchaser ………………………………………….
Address of purchaser ……………………………………….
IDENTIFYING DETAILS OF THE SALE
Model ………………………………………………………………
Series number ………………………………………………….
IMPORTANT:
- These details must be completed as clearly as possible and without delay by the supplier, who will stamp and sign on behalf of his company in the place indicated.
- The certificate remains in the possession of the purchaser.
- The purchaser must keep the RECEIPT for the purchase of the safe, together with the GUARANTEE CERTIFICATE to be able to accredit the date of purchase. Both documents are necessary to use the guarantee.
SUPPLIER’S STAMP
Arregui
Pol. Industrial Ubegun. 3B.
20809 Aia-Orio. Gipuzkoa
(SPAIN)
arregui@arregui.es
www.arregui.es
References
- Design of mailboxes, safes in Gipuzkoa - Arregui - Orio
- Diseño De Buzones, Cajas Fuertes en Gipuzkoa - Arregui - Orio Gipuzkoa
- Conception de boîtes aux lettres, coffres-forts à Gipuzkoa - Arregui - Orio
- Mailbox Design, casseforti in Gipuzkoa - Arregui - Orio Gipuzkoa
- Diseño De Buzones, Cajas Fuertes en Gipuzkoa - Arregui - Orio Gipuzkoa
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>