Kinco GREEN Series Widescreen HMI Touch Panel Instruction Manual

June 12, 2024
Kinco

GH043 /GH043E HMIKinco GREEN Series Widescreen HMI Touch
Panel Installation Instruction

Installation Note

1.1 Environmental Requirement
Operating temperature: GH043/GH043E HMI can work stably in most industrial environments that the temperature between-13°F to140°F (-25~60°C).
NEMA rating: This Series HMI frontpanel is NEMA 1 rated.

Please do not use in the following places:

  • Places direct in sunlight
  • Surroundingtemperature and humidity beyond the specifications
  • Places of temperature changes sharply and easily cause condensation
  • Places that exist corrosive gas and combustible gas
  • Places of much dust, dirt, salt and iron powder
  • Places that will be splashed water, oil and drugs

Pleasetakeshielding measures in the following places:

  • Places that exist electrostatic or other kinds of noise
  • Places of strong electromagnetic
  • Places that may be exposed to rays
  • Places near the power

1.2 Power Requirement

  • Input voltage:DC12 V~DC28V.
  • Particularly note that there must be enough distance between this product and converters or switch mode power supply. Make sure that the input and output cables of that kind equipment are shield cable and the shielding network is connected with the ground.
  • Make sure that the DC power and AC power is isolated.
  • Do not use common power with perceptual load or input circuit of the controller.

Note: An Internal fuse will prevent damage for over voltage condition, however it isn’t guaranteed the internal electronic components are not damaged.

Installation Description

2.1Dimensional DrawingKinco GREEN Series Widescreen HMI Touch Panel -
Drawing 2.2 Fixed Screw Installation Instructions
The product is put into the well mounted hole of the machine control box’s panel, and the mounting screws are inserted into the fixing holes around the HMI shell from the back of the control box’s panel.
Recommended lock torque: 0.5N.m (to waterproof effect and avoid shell deformation)Kinco GREEN Series Widescreen HMI Touch Panel -
Instructions 2.3 Power Connection
Before connecting the power, please make sure all local and national electrical standards are met.For power cables,please select cables with their dielectric strength values and current values in compliance with the safety specifications.
|First find the power terminal at the back of the product and loosen the screw according to counterclockwise, then insert the power cables and tighten the screw up.
Connect positive DC line to the ‘DC24V’ terminal, the DC ground to the ‘GND’ terminal and the ground line to the ’FG’ terminal.

External Interface

Kinco GREEN Series Widescreen HMI Touch Panel -
Interface 3.1 Ethernet(Only GH043E support)
10M/100M adaptive Ethernet RJ45 port.

Connection With CAT5 UTP cable connected to the Ethernet device.
Port Function The port can be used for upload/download of HMI configuration,

setting of system parameters and online simulations of configurations. It can connect multiple HMIs via the Ethernet to form an HMI network. Furthermore, it can implement communications between HMI and PLC via the Ethernet, as well as communications with a PC via the Ethernet port.

3.2 USB HOST

Connection Connect with USB interface devices or U disks
Port Function This interface can be connected with USB keyboard, mouse and

printers, and the U disk can be used for user’s configuration uploading/ downloading as well as data storage.

3.3 USB SLAVE
The interface type is MicroUSB

Connectio USB Slave port can be connected with a PC
Port Function The port is only used to download user configuration program to

the HMI and to set HMI system parameters.

3.4 COM0/COM2
Pin assignment of the 9-pin male, D-SUB, COM0/COM2.Note:
RS232/485/422 communication functions are supported by COM0.COM2 supports RS232 communication function.

Pin| Signal| PLC (COM0) [RS-422]| PLC(COM0) [RS-485]| PLC (COM0[RS-232]| PC/PLC (COM2) [RS-232]
---|---|---|---|---|---
1| Rx-(B)| RS422 R-| RS485 B| |
2| RxD_PLC| | | RS232 RxD|
3| TxD_PLC| | | RS232 TxD|
4| Tx-| RS422 T-| | |
5| GND| Signal ground
6| Rx+(A)| RS422 R+| RS485 A| |
7| RxD_PC| | | | RS232 RxD
8| TxD_PC| | | | RS232 TxD
9| Tx+| RS422 T+| | |

3.5 SD CARD

Connection Standard SD card interface
Port Function The SD Card can be inserted in through this interface for Data

storage and user configuration uploading/downloading.

After-sales Service

For < Service Terms and Conditions for HMI >, please check: http://www.kinco.cn

Kinco Electric (Shenzhen) Ltd.
Add:Building 1, No. 6 Langshan 1st Rd, Hi-tech Park North, Nanshan, Shenzhen, China.
Tel:0755-26585555
Fax:0755-26616372
http://www.kinco.com
Email:[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Kinco User Manuals

Related Manuals