Simply Retrofits VO-RF15W24-120-D-3Way CCT Adjustable 15 Inch Flush Mount Fixture Instructions
- June 10, 2024
- Simply Retrofits
Table of Contents
Simply Retrofits VO-RF15W24-120-D-3Way CCT Adjustable 15 Inch Flush Mount Fixture
CAUTION
TURN OFF THE MAIN POWER AT THE CIRCUT BREAKER BEFOR INSTALLING THE FIXTURE .IN ORDER TO PREVENT POSSIBLE SHOCK.
GENRAL
-
All electrical connections must be in accordance with local and National Electrical Code (N.E.C) Standards.
if you are unfamiliar with proper electrical wiring connection obtain the services of a qualified electrician. -
Remove the fixture and the mounting package from the box and make sure that no parts are missing by referencing the illustrations on the installation instruction’s.
IMPORTANT SRFETY INFORMATION
-
WARNING: RISK OF SHOCK House electric current can cause panful shock or serious injury unless handled properly. For your safety , always remember to;
A. Turn off the power Supply at the fuse or circuit breaker box before install the fixture .
B . Ground the fixture to avoid potential electric , shock s and to ensure reliable starting.
C. Double-Check all connections to be sure they ate tight and correct.
D. Wear rubber soled shoes and work on a sturdy wooden ladder. -
This fixture is designed for use in a circuit protected by a fuse or circuit breaker . it is also designed to be installed in accountanc with local electrical codes if you are unsure about your wiring , consult a qualified electrician or local electrical inspector , and check your local electrical code.
-
WIRNING : RISK OF CUTS Some meal parts in the fixature may have sharp edges. To prevent cuts and scrapes , wear gloves when handling the parts.
-
Account for small parts and destroy packing material as these may be hazardous to children.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received , including interference that may cause undesired Operation,
NOTE : This equipment has been tested and found to comply with the limits for class B digital device, pursuant to part 15 of the FCC Rules. These Limits are designed to provide reasonable protection against harmful Interference in residential installation. This equipment generates ,uses and can radiate radio frequency energy and , if not installed and used in accordance with the instructions , may cause harmful interference to radio communications However , there is no guarantee that interference will not occur in particular installation . if this equipment off and on, the user is encouraged to try correct the interference by one or more the following measures: Reorient or relocate the receiving antenna. increase the separation between the equipment into in out let in a circuit different from that to which the recover is connected. Consult the dealer or an experienced radio/TV technician for help.
Warranty:
Votatec offers a warranty of 5 years from the data of purchase that cover repair or replacement of defective parts of the housing , optics and electronics.
THE PRODUT PACKGE INCLUDES THE FOLLOWING COMPONENTS
- 1 piece Round Flush mount housing
- 1 piece Round flush mount Diffuser (Shipped as part of flus mount housing)
- 3 pieces wisents (in parts bag)
- 2 pieces 1-1/12 Electical Box Screws (in Parts bag)
- 1 piece installation Manual
MOUNTING INSTRUCTIONS
CHOOSING A COLOR TEMPERATURE BEFORE INSTALLING
- Use the slide switch to choose a color temperature before installing 5000k (5k) , 4000K (4k) , 3000K (3k)
3-ways color changing :
- You can lock in one color temperature , change among multiple color temperature , dim from 10% – 100%
- When the side switch is set BW (Bright White), the color temperature is set at 3000K.
- When the slide switch is set to DL (Daylight), the color temperature is set at 5000K.
MOUNTING INSTRUCTION
-
Carefully unpack and unwrap fixture.
-
Loosen 3 screw counter counterclockwise (Figure 1)
-
Install the electrical box screws in the junction box **(figure2)
**
-
Check of the fixture. Before wiring fixture to the power supply , turn off electricity at fuse or circuit breaker box . Fixture must be grounded to avoided potential electrical shock and to ensure reliable lamp starting.
-
Using WIRE NUTS to connect GROUNDING WIRE from fixture with the one from the Junction box. Connect the black and the white fixture wire with the two wires of the same colors from the junction box. (figure 3.)
-
Put the fixture plate across the screw of the lock in figure 2, the rotate fixture plate clockwise and lock it tightly with the screw lock (figure 4)
-
Securely mount the fixture plate to the junction box firmly (figure 5 )
-
Tighen 3 screw clockwise (figure 6)
-
Restore power to the electrical box . turn the light switch on.
-
Supplier at 12Vac.
VO-RF15W24-120-D-3Way
lumens per fixture
2000L
Total Consumption
24W
Light Color
3000K-4000K-5000K