antaira INJ-C201G-bt-100-T Industrial Gigabit Enhanced PoE Injector Installation Guide

June 12, 2024
antaira

antaira INJ-C201G-bt-100-24-T Industrial Gigabit Enhanced PoE Injector

antaira INJ-C201G-bt-100-T Industrial Gigabit Enhanced PoE
Injector

Package Check List

The package contains the following items:

  • 1 – Quick installation guide
  • 1 – INJ-C201G-bt-100-T
  • 1 – Wall mounting bracket set with screws
  • 1 – DC cable –18 AWG & DC jack 5.5 x 2.1mm

Front Panel Layout

Front Panel Layout

Top Panel View

INJ-C201G-bt-100-24-T top panel is equipped with one 4-pin removal terminal block connector for dual DC power inputs (9~55VDC) and one 2-pin removal terminal block for fault alarm.
Top Panel View

Product Overview

System Interface/Performance

  • 10/100/1000BaseT Power over Ethernet Injector
  • IEEE 802.3af/at/bt Compliant PoE
  • Provides Power Feeding up to 100 Watts
  • Power booster technologies for low voltage power inputs

Power Input & Connection

  • DC 9 to 55V redundant power, with one 4-pin removal terminal block

Operating Temperature

  • Extended operating temperature model: -40°C to 75°C

Case/Installation

  • IP30 protection
  • DIN-Rail and Wall mount design

LED Indicators

LED Color Description
Power Green On
Red On Power input 1 or 2 is inactive, trigger relay
Off Power input 1 and 2 is inactive
PoE Amber On

over 2 pairs
Green| On| The PoE output port is supplying power to the powered-device over 4 pairs
Amber| Flashing| The PoE output port is supplying power to the powered-device over 2 pairs after the Dual PD Check event happens.
(Only occurs when Dual PD Check function is disabled)


Green

| ****

Flashing

| The PoE output port once supplied power to the powered-device over 2 pairs and now recovers to supply power over 4 pairs.
–| Off| No powered-device attached or power supplying fails
P/L| –| Off| Actual Consumption ≦30W
Blue| On| 31W≦ Actual Consumption ≦60W
Red| On| 61W≦ Actual Consumption ≦90W
Red| Flashing| 91W≦ Actual Consumption ≦100W

(Only occurs when PoE enhanced mode is enabled)

DIP-Switch Setting

There are 2-set DIP-switch in front panel, that can be used for setting the PoE Mode and Dual PD Check functions.

DIP-Switch ON OFF (Default)
1 Enhanced PoE Mode Standard PoE Mode
2 Dual PD Check Enabled Dual PD Check Disabled

Quick Installation

Ethernet Ports

RJ45 Ports (Auto MDI/MDI-X)

All RJ45 ports are auto-sensing for 10Base-T, 100Base-TX or 1000Base-T device connections. Please follow the wiring pin assignment table below for Ethernet port installation.

RJ45 Ethernet Port Pin Outs

Pins| T568A Color| T568B Color| 10Base-T, 100Base-TX| 1000 Base-T(X)
Pin 1| white/green stripe| white/orange stripe| Rx+| TP0+
Pin 2| green solid| orange solid| Rx-| TP0-
Pin 3| white/orange stripe| white/green stripe| Tx+| TP1+
Pin 4| blue solid| blue solid| unused| TP2+
Pin 5| white/blue stripe| white/blue stripe| unused| TP2-
Pin 6| orange solid| green solid| Tx-| TP1-
Pin 7| white/brown stripe| white/brown stripe| unused| TP3+
Pin 8| brown solid| brown solid| unused| TP3-

Power Inputs Wiring

Please follow the steps below to insert the power wire:

  1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block connector as shown below in Figure 1.
  2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure 2.

Industrial PoE Injector Mounting

DIN-Rail Mounting

The DIN-Rail bracket is pre-installed on the industrial PoE injector from the factory. Please refer to Figure 3 for a DIN-Rail bracket installation reference. Follow the steps below for installing the industrial PoE injector on the DIN-Rail track:

  1. Insert the top of the DIN-Rail onto the track as shown below in Figure 4.
  2. Lightly pull down the bracket onto the rail as shown below in Figure 5.
  3. Check if the bracket is mounted tightly on the rail.
  4. To remove the industrial PoE injector from the rail, do the opposite from the steps above.
    Industrial PoE injector Mounting

Wall Mounting

Follow the steps below to mount the industrial PoE injector using the wall mounting bracket as shown in Figure 6.

  1. Remove the DIN-Rail bracket from the industrial PoE injector by loosening the screws.
  2. Place the wall mounting brackets on the top and bottom of the industrial PoE injector.
  3. Use the screws to screw the wall mounting bracket on the industrial PoE injector.
  4. Use the hook holes at the corners of the wall mounting bracket to hang the industrial PoE injector on the wall.
  5. To remove the wall mount bracket, do the opposite from the steps above.
    Wall Mounting

Field Maintenance and Service

  • If the device requires servicing of any kind, the user is required to disconnect and remove it from its mounting. The initial installation should be done in a way that makes this as convenient as possible.
  • Voltage/power lines should be properly insulated as well as other cables. Be careful when handling them so as to not trip over.
  • Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces of the device. This may not only harm the internal layout, but might cause harm to the user as well.
  • Do not under any circumstance open the device for any reason. Please contact your dealer for any repair needed or follow the instructions within the manual.

Warranty Policy

Warranty Conditions
Products supplied by Antaira Technologies are covered in this warranty for sub-standard performance or defective workmanship. The warranty is not, however, extended to goods damaged in the following circumstances:

(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts

RMA and Shipping Costs Reimbursement
Customers shall always obtain an authorized “RMA” number from Antaira before shipping the goods for repair or replacement.

  • Within the warranty period (based on the invoice date), all parts and labor are free of charge to the customers.
  • Customers are responsible for the cost of parts and labor, if the products are out of warranty.
  • For RMA service, customers are responsible for the shipping expense for shipping the RMA unit(s) to Antaira. Antaira is responsible for the shipping expense via a ground service for the return repair/replace unit(s) back to customers.

Limited Liability

Antaira would not be held responsible for any consequential losses from using Antaira’s product.

Warranty Period

5-Year Warranty

Customer Support

Antaira’s Customer Service and Support

*Any changes will be announced on the Antaira website.
Tel: 1-844-268-2472
Fax: 1-714-671-9944
www.antaira.com

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

antaira User Manuals

Related Manuals