Aquaviva REDOX1 Redox Analyzer for Chlorinator Control Instruction Manual

June 12, 2024
Aquaviva

REDOX1 Redox Analyzer for Chlorinator Control
Instruction Manual

PACK CONTENTS

A) Control device (standard model)
B) Attachment screw ( =6 mm)
C) SRH-1 Rx electrode
D) 465mV buffer solution
E) PSS3 probe-socket (1/2” GAS)
F) Tapping saddle for securing PSS3 onto 2″ hose ( =50 mm)

Aquaviva REDOX1 Redox Analyzer for Chlorinator Control -
Control Wall Mounting Setup

TECHNICAL SPECIFICATIONS

Dimensions (H — W — L) 234x162x108 mm
Weight 1 kg
Power supply 50 Hz 230 VAC
Output system 230 VAC
Consumption 12 W
Measure scale 0+ +1000 mV
Device precision ± 10 mV
Device accuracy ± 2 mV
Electrode regulation Automatic

ATTENZIONE / WARNING / ATTENTION / ACHTUNG

Aquaviva REDOX1 Redox Analyzer for Chlorinator Control -
warning

Instruction Setting

Functions:

  • Calibration
    o (Press for3Seconds):
    o Standard Routine calibration for 465mV buffer solution

  • Set Point
    .  Press .
    . Keep Press Set Key and adjust value with
    .

  • Press for 5 Seconds and run Program Setup:

• Press to set the following Item
• It’s possible to have 5 language EN, IT, SP, DE, FR

•Adjust value with and
• It’s possible to enable(ON) or disable (OFF) signal input


o Adjust value with .and ‘
• It’s possible to adjust from 0 to 1000 mV

• Adjustvalue. and
It’s possible to adjust dosing, High or Low for Redox.

Adjust value .
It’s possible to adjust OFA time in minutes

• Adjust value . and
• ts possible to select 465mV or function disable.

.Adjust value .

  • Save and escape Program setup with ESC key

. Adjust value with up or down key and confirm with .

  •  Priming Pump Keep Press for 3 seconds

Wire Connection:

  1. Input Redox Probe
  2. Input Temperature Probe (PT100)
  3. Input Level Probe (Product Tank
  4. Input Flow Rate (High Voltage 230 Vac)
  5. Output Relay Alarm remote (Dry contact, Relay 250 Vac 10 A)
  6.  Output Relay Drive Solenoid Valve (Dry contact,Relay 250 Vac 10 A)
  7. Power Supply 230 Vac
  8. Switch Power Supply

Aquaviva REDOX1 Redox Analyzer for Chlorinator Control -
Wire

Redox Probe Calibration

Aquaviva REDOX1 Redox Analyzer for Chlorinator Control -
RedoxAquaviva REDOX1 Redox Analyzer
for Chlorinator Control - Redox 1

Alarm Display Relay Actions to do
Level Alarm Relay Close – Push Enter Key to open Alarm Relay

– Restore Product tank
OFA First Alarm (time >70%)| | open| Alar
OFA Second Alarm (time =100%)| | Alarm Relay Close| Push Enter Key to reset
Flow Rate| | Alarm Relay open|
Restore Flow Rate
System Error| | Alarm Relay Open| – Press Enter Key to replace Default parameter
– Destroy Unit
Calibration Funciont| | Alarm Relay open| – Restore Probe or Buffer solution and repeat calibration function

Default parameters:

  •  Language = UK
  • SetPointvalue= 750mV
  • Dosing Method = Low
  • Time OFA = OFF
  • Calibration = 465mV
  • Flow Input= OFF

To restore Default parameters run Following steps:

  • Power off the unit
  • Keeping Press UP and DOWN Key switch on the Power.
  • The unit will flash
  • Press up
  • Enter Key to restore Default parameters.

Code 0000137239
rev. 1.0

Documents / Resources

| Aquaviva REDOX1 Redox Analyzer for Chlorinator Control [pdf] Instruction Manual
REDOX1, REDOX1 Redox Analyzer for Chlorinator Control, Redox Analyzer for Chlorinator Control, Analyzer for Chlorinator Control, Chlorinator Control
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals