Aquaviva REDOX1 Redox Analyzer for Chlorinator Control Instruction Manual
- June 12, 2024
- Aquaviva
Table of Contents
REDOX1 Redox Analyzer for Chlorinator Control
Instruction Manual
PACK CONTENTS
A) Control device (standard model)
B) Attachment screw ( =6 mm)
C) SRH-1 Rx electrode
D) 465mV buffer solution
E) PSS3 probe-socket (1/2” GAS)
F) Tapping saddle for securing PSS3 onto 2″ hose ( =50 mm)
Wall Mounting Setup
TECHNICAL SPECIFICATIONS
Dimensions (H — W — L) | 234x162x108 mm |
---|---|
Weight | 1 kg |
Power supply 50 Hz | 230 VAC |
Output system | 230 VAC |
Consumption | 12 W |
Measure scale | 0+ +1000 mV |
Device precision | ± 10 mV |
Device accuracy | ± 2 mV |
Electrode regulation | Automatic |
ATTENZIONE / WARNING / ATTENTION / ACHTUNG
Instruction Setting
Functions:
-
Calibration
o (Press for3Seconds):
o Standard Routine calibration for 465mV buffer solution -
Set Point
. Press .
. Keep Press Set Key and adjust value with
. -
Press for 5 Seconds and run Program Setup:
• Press to set the following Item
• It’s possible to have 5 language EN, IT, SP, DE, FR
•
•Adjust value with and
• It’s possible to enable(ON) or disable (OFF) signal input
•
o Adjust value with .and ‘
• It’s possible to adjust from 0 to 1000 mV
• Adjustvalue. and
It’s possible to adjust dosing, High or Low for Redox.
Adjust value .
It’s possible to adjust OFA time in minutes
• Adjust value . and
• ts possible to select 465mV or function disable.
.Adjust value .
- Save and escape Program setup with ESC key
. Adjust value with up or down key and confirm with .
- Priming Pump Keep Press for 3 seconds
Wire Connection:
- Input Redox Probe
- Input Temperature Probe (PT100)
- Input Level Probe (Product Tank
- Input Flow Rate (High Voltage 230 Vac)
- Output Relay Alarm remote (Dry contact, Relay 250 Vac 10 A)
- Output Relay Drive Solenoid Valve (Dry contact,Relay 250 Vac 10 A)
- Power Supply 230 Vac
- Switch Power Supply
Redox Probe Calibration
Alarm | Display | Relay | Actions to do |
---|---|---|---|
Level | Alarm Relay Close | – Push Enter Key to open Alarm Relay |
– Restore Product tank
OFA First Alarm (time >70%)| | open| Alar
OFA Second Alarm (time =100%)| | Alarm Relay Close| Push Enter Key to reset
Flow Rate| | Alarm Relay open| Restore Flow Rate
System Error| | Alarm Relay Open| – Press Enter Key to replace Default
parameter
– Destroy Unit
Calibration Funciont| | Alarm Relay open| – Restore Probe or Buffer solution
and repeat calibration function
Default parameters:
- Language = UK
- SetPointvalue= 750mV
- Dosing Method = Low
- Time OFA = OFF
- Calibration = 465mV
- Flow Input= OFF
To restore Default parameters run Following steps:
- Power off the unit
- Keeping Press UP and DOWN Key switch on the Power.
- The unit will flash
- Press up
- Enter Key to restore Default parameters.
Code 0000137239
rev. 1.0
Documents / Resources
|
Aquaviva REDOX1 Redox Analyzer for Chlorinator
Control
[pdf] Instruction Manual
REDOX1, REDOX1 Redox Analyzer for Chlorinator Control, Redox Analyzer for
Chlorinator Control, Analyzer for Chlorinator Control, Chlorinator Control
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>