Aquaviva pH · ORP SMV Smart Plus Instruction Manual
- June 12, 2024
- Aquaviva
Table of Contents
Aquaviva pH · ORP SMV Smart Plus
WARNING!
Before carrying out ANY work inside control panel of the Smart Plus device, make sure you disconnect it from the power supply.
Failure to comply with the instructions contained in this manual could cause injury to people and/or damage to the appliance and the system.
WARNING!
These products are DANGEROUS and require special precautions during use, handling and storage.
- NEVER mix chemical products.
- NEVER allow children or people who have not read this manual to use or tamper with Smart Plus or any of its peripheral components (including chemical products).
pH chemical products:
- ABSOLUTELY not recommended => pure sulphuric acid
- Recommended for lowering pH => negative pH (with a sulphuric acid base)
- Recommended for raising pH => positive pH (sodium carbonate or bicarbonate)
ORP chemical products:
- ABSOLUTELY not recommended => all types of organic chlorine
The pH / ORP probes are subject to wear and tear and therefore are not covered by the warranty.
INSTALLATION INSTRUCTIONS
Make sure that the injection pressure is below 1.5 bar
Probe positioning
Installation plant
Warning!
Use with salt chlorinator:
For the pH systems, to prevent the risk of system malfunctioning or damage, observe the following instructions:
- Position the pH measuring probe prior to the chlorinator cell.
- To eliminate eddy currents, connect the pool water to an electrical ground point
- Position the product injection point after the chlorinator cell.
ELECTRICAL CONNECTIONS
Connect the power supply cable to the mains and the servo control pre-wired
cable to the auxiliary contact of the filter box (230 Vca).
Wiring diagram:
- Input Level Probe (Product Tank)
- Input Frequency signal by Water meter pulse sender
- RS485 Serial Port (optional)
- Input Temperature Probe (PT100 sensor not included)
- Output Relay Auxiliary Pump (Dry contact, Relay 250 Vac 10 A)
- Output Relay Alarm remote (Dry contact, Relay 250 Vac 10 A)
TECHNICAL SPECIFICATIONS
Specifications | Smart Plus pH | Smart Plus ORP |
---|---|---|
Measure range | 3.0 ÷ 10.0 pH | 200 ÷ 999 mV |
Set Point range | 6.0 ÷ 8.0 pH | 400 ÷ 850 mV |
Alarm range | 5.0 ÷ 9.0 pH | 300 ÷ 900 mV |
Accuracy | ± 0.04 pH | ± 2 mV |
Resolution | 0.01 pH | 1 mV |
Power supply | 230 VAC 50 Hz | |
Insulation class | II | |
Consumption | 10 W | |
Pump flow rate | 1.6 l/h | |
Max. back-pressure | 1.5 bar | |
Probe calibration | Automatic | |
Pump state | Proportional dosing | |
Peristaltic tube (ID x OD mm) | Norprene 4.8 x 8 mm | |
Dimensions (H x W x D mm) | 185 x 124 x 110 mm | |
Weight | 1.0 kg |
SETUP INSTRUCTIONS POOLMATCH SYSTEM
- Button to increase the value
- Button to decrease the value
- Button Menu/Esc
- Button Cal/OK
- Button to set the setpoint
- Digital display
Program Setup – Press for 5 seconds
At the entry of each menu item, the parameter can be directly modified using the arrow keys ( and ). Confirmation of the current setting and switching to the next item is done by pressing the button. The menu has a circular structure: once you arrive at last item, the confirmation of the parameter set by pressing , determines the return to the first menu item.
-
It is possible to select between 5 available languages: EN, FR, IT, DE, ES
-
7.4pH (5-9pH) / 700mV (300-900mV)
-
Acid (Acid/Alka) / Low (Low/High)
4 = 30seconds (range from 1 to 360 seconds)
5 = 60seconds (range from 1 to 360 seconds) -
4.1 – (Enabled/disabled)
4.2 – (Auto/Manual 25°C)
4.3 – (0-60min.)
4.4 This menu is available only for models that have the RS485 Modbus connector
4.5 • Pulse/ liter 1:1
• Unit measure m³, l.
4.6 • Two points Single point Reference
4.7 • On/Off
• Timed
• Off
Save and exit Program setup – Press
Pressing the key determines the exit from the programming menu with saving of the parameters, if the parameter of the menu item in which one is in has not been changed when pressing the key.
Set Point adjustment
Press the button for 3 seconds, use and to set the desired value.
Stand-by mode (backlight on)
Press and buttons simultaneously for 5 seconds to switch off the unit backlight. Dosage and calibration are disabled. To exit standby, press and buttons simultaneously.
Priming
Only while the pump is in stand-by press down and in the same time.
Flowrate counter reset
To reset value of “Permanent Totalizer” press button for 3 seconds, in stand- by mode only.
Offset/Slope Menu
Press and buttons the unit show Offset/Slope calibration value, press or to scroll the menu.
pH CALIBRATION
ORP CALIBRATION
PROPORTIONAL DOSING
Setpoint = 7.4 pH
Dosing mode = Acid
Setpoint = 700 mV
Dosing mode = Low
ALARMS
Alarm| Display Smart Plus pH| Display Smart Plus ORP|
Actions to do
---|---|---|---
Level| | |
- Restore Product tank
Measure out of range| (<5 pH) (>9pH)| (<100 mV)|
- Replace or check the measure probe
- Restore pH / ORP
OFA Alarm (time >OFA time)| | | measure
- Push to reset
Flow Rate| | |
- Restore Flow Rate
Calibration Function| | |
- Restore Probe or Buffer solution and repeat calibration procedure
System Error| |
- Press to restore Default parameter
- Broken Unit
Modbus Error| |
- Press to reset
- Restore communication
To restore the default parameters, follow the steps below:
- Power off the Smart Plus unit
- Keep and pressed and power on the unit
- The unit will flash
- Press
- Press to restore the default parameters.
Default Parameters
| Smart Plus pH|
Smart Plus ORP
---|---|---
Language
| EN
Time OFA|
OFF
Flow Input
| OFF
Set Point value| 7.4 pH|
700 mV
Calibration
| 7 pH / 4 pH (2-point)| 475 mV
Dosing Method| Acid|
Low
HANDLING
Hose replacement:
Open the pump’s lid and release the hose by pulling the left connector upward.
Position the roller at 7h05, turning it in the direction of the circular arrow.
Completely release the left connector, holding it taut towards the outside, and turn the roller in the direction of the circular arrow so that the hose is freed up to the right connector.
Position the roller at 7h05, turning it in the direction of the circular arrow.
Insert the left connector into the relative housing and pass the hose under
the roller’s guide. Turn the roller in the direction of the circular arrow,
simultaneously accompanying the hose into the pump’s head, until the right
connector is reached.
Close the pump’s lid and press its surface hard so that it is properly locked into place.
Read User Manual Online (PDF format)