Aquaviva pH · ORP SMV Smart Plus Instruction Manual

June 12, 2024
Aquaviva

Aquaviva pH · ORP SMV Smart Plus

Aquaviva pH · ORP SMV Smart Plus

WARNING!

Before carrying out ANY work inside control panel of the Smart Plus device, make sure you disconnect it from the power supply.

Failure to comply with the instructions contained in this manual could cause injury to people and/or damage to the appliance and the system.

WARNING!

These products are DANGEROUS and require special precautions during use, handling and storage.

  • NEVER mix chemical products.
  • NEVER allow children or people who have not read this manual to use or tamper with Smart Plus or any of its peripheral components (including chemical products).

pH chemical products:

  • ABSOLUTELY not recommended => pure sulphuric acid
  • Recommended for lowering pH => negative pH (with a sulphuric acid base)
  • Recommended for raising pH => positive pH (sodium carbonate or bicarbonate)

ORP chemical products:

  • ABSOLUTELY not recommended => all types of organic chlorine

The pH / ORP probes are subject to wear and tear and therefore are not covered by the warranty.

INSTALLATION INSTRUCTIONS

Installation Instructions

Make sure that the injection pressure is below 1.5 bar

Probe positioning

Installation Instructions

Installation plant

Installation Instructions

Warning!

Use with salt chlorinator:

For the pH systems, to prevent the risk of system malfunctioning or damage, observe the following instructions:

  1. Position the pH measuring probe prior to the chlorinator cell.
  2. To eliminate eddy currents, connect the pool water to an electrical ground point
  3. Position the product injection point after the chlorinator cell.

ELECTRICAL CONNECTIONS

Connect the power supply cable to the mains and the servo control pre-wired cable to the auxiliary contact of the filter box (230 Vca).
Electrical Connections
Electrical Connections

Wiring diagram:

  1. Input Level Probe (Product Tank)
  2. Input Frequency signal by Water meter pulse sender
  3. RS485 Serial Port (optional)
  4. Input Temperature Probe (PT100 sensor not included)
  5. Output Relay Auxiliary Pump (Dry contact, Relay 250 Vac 10 A)
  6. Output Relay Alarm remote (Dry contact, Relay 250 Vac 10 A)
    Electrical Connections

TECHNICAL SPECIFICATIONS

Specifications Smart Plus pH Smart Plus ORP
Measure range 3.0 ÷ 10.0 pH 200 ÷ 999 mV
Set Point range 6.0 ÷ 8.0 pH 400 ÷ 850 mV
Alarm range 5.0 ÷ 9.0 pH 300 ÷ 900 mV
Accuracy ± 0.04 pH ± 2 mV
Resolution 0.01 pH 1 mV
Power supply 230 VAC 50 Hz
Insulation class II
Consumption 10 W
Pump flow rate 1.6 l/h
Max. back-pressure 1.5 bar
Probe calibration Automatic
Pump state Proportional dosing
Peristaltic tube (ID x OD mm) Norprene 4.8 x 8 mm
Dimensions (H x W x D mm) 185 x 124 x 110 mm
Weight 1.0 kg

SETUP INSTRUCTIONS POOLMATCH SYSTEM

Setup Instructions Poolmatch System

  1. Button to increase the value
  2. Button to decrease the value
  3. Button Menu/Esc
  4. Button Cal/OK
  5. Button to set the setpoint
  6. Digital display

Program Setup – Press  for 5 seconds

At the entry of each menu item, the parameter can be directly modified using the arrow keys ( and ). Confirmation of the current setting and switching to the next item is done by pressing the  button. The menu has a circular structure: once you arrive at last item, the confirmation of the parameter set by pressing , determines the return to the first menu item.

  1. It is possible to select between 5 available languages: EN, FR, IT, DE, ES

  2. 7.4pH (5-9pH) / 700mV (300-900mV)

  3.  Acid (Acid/Alka) / Low (Low/High)
    4 = 30seconds (range from 1 to 360 seconds)
    5 = 60seconds (range from 1 to 360 seconds)

  4. 4.1 – (Enabled/disabled)
    4.2 – (Auto/Manual 25°C)
    4.3 – (0-60min.)
    4.4 This menu is available only for models that have the RS485 Modbus connector
    4.5 • Pulse/ liter 1:1
    • Unit measure m³, l.
    4.6 • Two points Single point Reference
    4.7 • On/Off
    • Timed
    • Off

Save and exit Program setup – Press

Pressing the  key determines the exit from the programming menu with saving of the parameters, if the parameter of the menu item in which one is in has not been changed when pressing the  key.

Set Point adjustment

Press the button for 3 seconds, use  and to set the desired value.

Stand-by mode (backlight on)

Press  and buttons simultaneously for 5 seconds to switch off the unit backlight. Dosage and calibration are disabled. To exit standby, press  and buttons simultaneously.

Priming

Only while the pump is in stand-by press down and  in the same time.

Flowrate counter reset

To reset value of “Permanent Totalizer” press button for 3 seconds, in stand- by mode only.

Offset/Slope Menu

Press  and buttons the unit show Offset/Slope calibration value, press or  to scroll the menu.

Setup Instructions Poolmatch System

pH CALIBRATION

Ph Calibration

ORP CALIBRATION

Orp Calibration

PROPORTIONAL DOSING

Setpoint = 7.4 pH
Dosing mode = Acid

Proportional Dosing

Setpoint = 700 mV
Dosing mode = Low

Proportional Dosing

ALARMS

Alarm| Display Smart Plus pH| Display Smart Plus ORP|

Actions to do

---|---|---|---
Level| | |

  • Restore Product tank

Measure out of range| (<5 pH) (>9pH)| (<100 mV)|

  • Replace or check the measure probe
  • Restore pH / ORP

OFA Alarm (time >OFA time)| | | measure

  • Push to reset

Flow Rate| | |

  • Restore Flow Rate

Calibration Function| | |

  • Restore Probe or Buffer solution and repeat calibration procedure

System Error| |

  • Press to restore Default parameter
  • Broken Unit

Modbus Error| |

  • Press to reset
  • Restore communication

To restore the default parameters, follow the steps below:

  • Power off the Smart Plus unit
  • Keep and pressed and power on the unit
  • The unit will flash
  • Press
  • Press to restore the default parameters.

Default Parameters

| Smart Plus pH|

Smart Plus ORP

---|---|---

Language

| EN
Time OFA|

OFF

Flow Input

| OFF
Set Point value| 7.4 pH|

700 mV

Calibration

| 7 pH / 4 pH (2-point)| 475 mV
Dosing Method| Acid|

Low

HANDLING

Hose replacement:

Open the pump’s lid and release the hose by pulling the left connector upward.

Position the roller at 7h05, turning it in the direction of the circular arrow.

Completely release the left connector, holding it taut towards the outside, and turn the roller in the direction of the circular arrow so that the hose is freed up to the right connector.

Position the roller at 7h05, turning it in the direction of the circular arrow.

Handling
Insert the left connector into the relative housing and pass the hose under the roller’s guide. Turn the roller in the direction of the circular arrow, simultaneously accompanying the hose into the pump’s head, until the right connector is reached.

Close the pump’s lid and press its surface hard so that it is properly locked into place.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals