WARNING
FOR USE WITH RANGE HOODS ONLY.
GROUNDING INSTRUCTIONS
Range Hoods must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. After attaching this cord kit to the range hood, it is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING – Improper grounding can result in a risk of electric shock.
Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.
This kit includes the following:
(1) 36” Cord & Plug with Cord Connector
(1) Anti-Rotation Plate with Lock Bushing
(2) Wire Nuts
CAUTION
TO REDUCE THE RISK OF FIRE AND ELECTRICAL SHOCK, THIS RANGE HOOD CORD- CONNECTION KIT IS cULus CERTIFIED ONLY FOR USE WITH THE RANGE HOOD MODEL SERIES LISTED BELOW:
BROAN SERIES
40000, 41000, 42000,
43000, 46000,BCDF1,
BCDJ1, BCSD1,
BCSEK1, BKDB1,
BKDEG1, BKSA1,
BKSH1, TEN1, TEN2,
BPDP1, ALT1, ALT2,
ALT3, CLDA1, CLDH1,
CLSC1, CRDE1,
CRSF1, SPE1, ALT4 and BXT1
NUTONE SERIES
RL, ACS, AR1,
AHDA1, AHSA1,
AVDF1, AVSF1 and NPDP1
KENMORE SERIES
5094, 5104, 5134, 5164, 5184, 5324, 5334,
5128, 5139, 5141, 5129, 5126, 5135 and 5140
Other cord kits are not cULus certified – unless the specific model numbers are listed.
ELECTRICAL RECEPTACLE LOCATION
A grounded, electrical receptacle for this cord kit must be in a location that
will not allow the cord to come in contact with any heat source. Inside the
cabinet above the range is the most common location.
Do not plug into receptacles that would permit cord to come into contact with heat sources.
CORD KIT INSTALLATION
WIRING CONNECTIONS
4. Connect black wires together. Connect white wires together. Connect green ground wire beneath ground screw.
- If the range hood has an internal ground connection beneath a ground screw, A SECOND GROUND SCREW MUST BE USED for the cord kit ground.