mr steam ChromaSteam3 The Sauna Place Installation Guide
IMPORTANT SAFETY INFORMATION
READ ME FIRST:
- Read and follow all instructions within this technical manual.
- Heed all warnings, cautions, notices, and important notes.
- Save this technical manual and leave with the homeowner.
ABOUT WARNINGS, CAUTIONS, NOTICES, AND IMPORTANT NOTES:
As you follow the instructions in this technical manual, you will see four
types of callouts: WARNINGS, CAUTIONS, NOTICES, and
IMPORTANT NOTES.
This blocked information is important for the safe and efficient installation,
operation, and maintenance of the ChromaSteam3. These callouts are described
as follows
WARNING
Indicates a potentially hazardous situation, which, if not avoided, may result
in death or serious injury
CAUTION
Indicates a potentially hazardous situation, which, if not avoided, may result
in minor or moderate injury
NOTICE
Indicates a situation, which, if not avoided, may result in property damage.
IMPORTANT NOTE Indicates information that is especially relevant to a problem-free installation.
SAFETY INSTRUCTIONS
To prevent personal injury and/or product damage, please read the following important safety instructions carefully before installing the ChromaSteam3
- Do not install the ChromaSteam3 controller near any heat sources.
- Clearance and minimum distance between the various components of the ChromaSteam3 and the surrounding structure are not specified as long as they are sufficient so that the ambient temperature around the apparatus does not exceed 140 °F (60 °C).
- Do not defeat the safety purpose of the polarized and/or grounding type plug. A polarized plug has two blades, with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cords from being walked on or pinched, particularly at plugs, convenience receptacles, and at the point where the cords exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- All servicing to be performed by qualified service personnel. Servicing is required when the ChromaSteam3 is damaged in any way, including when the power-supply cord or plug is damaged, liquid is spilled into or objects fall into the controller, the controller is exposed to rain or moisture, the fixture or controller does not operate normally, or the fixture or controller is dropped.
- Do not disassemble or alter the ChromaSteam3 fixture or controller in any way.
- Clean the ChromaSteam3 fixture and controller with a dry cloth only. Beware of the application of some products commonly used against corrosion (such as WD-40® family products), as some industrial oils can have negative chemical reactions and damage the housing materials of the ChromaSteam3 fixture and controller. Any other materials that may come in contact with the ChromaSteam3 must be carefully evaluated under end-use conditions for compatibility
WARNING
These instructions are for use by qualified service personnel only. To reduce
the risk of electric shock, do not perform any servicing, other than that
contained in these instructions.
NOTE: All information in this technical manual is based on the latest product information available at the time of publication. Sussman-Automatic Corporation reserves the right to make changes at any time without notice.
mr.steam®
Sussman-Automatic Corporation® www.mrsteam.com
hello@mrsteam.com 43-20 34th Street, Long Island
City NY 11101 1 800 76 STEAM FAX: 718 472 3256 9410 S. La Cienega Blvd.,
Inglewood CA 90301 1 800 72 STEAM FAX: 310 216 2944
General Information
ChromaSteam3 Box Contents:
-
Junction Box
-
Chroma Steam3 Fixture
-
30-foot Cable
-
Control Box
-
Tube of Silicone
ChromaSteam3 Duo Box Contents:
-
(2) Junction Boxes
-
(2) Chroma Steam3 Fixtures
-
30-foot Cable
-
Duo Cable
-
Control Box
-
(2) Tubes Silicone
About color-matching the connections between cables and accessories
In order to help ensure that MrSteam cables and accessories are connected
correctly, all cable ends have been color-coded with flags (Figure 1), and
all accessory connectors/ports have been color-coded with adhesive dots
(Figure 2). When connecting cables and accessory connectors, ensure that
their respective flags and/or adhesive dots match in color. Figure 3 shows
the colors (purple, white, blue, red, and yellow) used between each
ChromaSteam3 connection
General Installation
Figure 3 shows how the ChromaSteam3 fixture and control box interconnect
with each other, and with the steam generator and iSteam3.
MPORTANT NOTES
- The included ChromaSteam3 control cable is 30 feet long. Ensure that the ChromaSteam3 fixture and control box are located accordingly. Contact MrSteam to purchase an optional 60-foot cable (PN 104268-60).
- ChromaSteam3 Duo cable has (2) 5 feet long extensions, it enables (2) ChromaSteam3 fixtures to be located at a maximum of 10 feet apart.
- The cord between the control box and steam generator is 5 feet long.
- ChromaSteam3 only works with iSteam3.
Installing the ChromaSteam3 Control Box
Control Box Dimensions
NOTICE
- To prevent product or property damage, do not expose control box to temperatures above 140 °F (60 °C). Do not locate control box in an attic or any location where ambient temperatures may exceed 140 °F (60 °C).
- Do not locate control box next to heat sources, such as hot air registers, air conditioner condensers, etc.
- The control box powers the ChromaSteam3 fixture with 5VDC 1.6A maximum.
Locating the Control Box
Determine the desired location of the ChromaSteam3 control box outside the
steam room in a dry location
WARNING
Shock hazard. Do not place the control box in a location where it can get
wet.
IMPORTANT NOTE: The ChromaSteam3 control cable is 30 feet long. Ensure that the ChromaSteam3 fixture and control box are located accordingly. Contact MrSteam to purchase an optional 60-foot cable (PN104268-60).
Installing the Control Box
Using screws and washers, affix the control box to a stable vertical surface (e.g., stud) using the mounting holes on either side of the control box **(Figure 4)
**
NOTICE
- The control box must be mounted in a vertical position as shown in Figure 4 to allow proper heat dissipation. Failure to mount as shown may cause thermal protection shut off.
- To prevent product or property damage, do not expose control box to temperatures above 140 °F (60 °C). Do not locate control box in an attic or any location where ambient temperatures may exceed 140 °F (60 °C).
- In the event the control box requires servicing, ensure that it is installed in an accessible location.
IMPORTANT NOTE: The following materials (not included) are recommended to install the ChromaSteam3 control box:
- Two #10 screws of appropriate length with round, truss, or pan head.
- Two washers with 0.5” outer diameter x 0.0625” thickness (12 mm outer diameter x 1.5 mm thickness).
Installing the ChromaSteam3 Fixture
Fixture Dimensions
Installing the Junction Box
Functions of the Junction Box:
- Allows precisely location of the ChromaSteam3 fixture within the steam room ceiling.
- Provides a secure and easily identifiable holder for the control cable while the steam room is being constructed.
- Works with the ChromaSteam3 fixture’s retention springs to prevent the fixture from falling and injuring a person in the enclosure.
Locating the Fixture:
- Locate the fixture in a location for optimal lighting within the enclosure.
- ChromaSteam3 is for mood lighting only. Not to be used as a primary lighting source.
- Do not locate the fixture in direct shower spray, near direct steam emission, or in any location where a lighting fixture may be damaged.
IMPORTANT NOTE: Maximum distance between the two fixtures is 10 feet.
To Install the Junction Box:
-
Remove the two screws from the interior clips of the junction box, and hand-screw them into the wings of the junction box (Figure 7).
-
Remove one of the four knockouts from the junction box (Figure 7). the resulting hole will allow routing of the 30-foot control cable or Duo cable into the junction box..
-
Locate the two tabs on the junction box, and line them up against a ceiling joist. The tabs locate the junction box proud of (slightly raised from) the joist. Screw the two screws into the ceiling joist to secure the junction box (Figure 8).
-
Route one end of the 30-foot control cable or one of the longer ends of the Duo cable (with a yellow flag stating “To Fixture”) through the knockout into the junction box, and fasten it to one of the interior clips to hold it in place (Figure 9). Note that both longer ends of the 30- foot control cable are the same.
IMPORTANT NOTE : Contact MrSteam to purchase an optional 60-foot cable (Part No. 104268-60).
NOTICE
- Route cable as required to permit replacement.
- Cable should be run in dedicated conduit to facilitate installation, service, and replacement.
- To prevent damage to the cable, do not route cable close to hot water, steam piping, or any heat source.
-
After the junction box is completely installed, ensure that you create an opening in the steam room ceiling that aligns with the junction box (Figure 10).
WARNING
- Installation to be performed by a qualified and licensed electrician.
- Shock Hazard. Ensure that power is turned off during installation. Turn off power at breaker panel.
CAUTION
NOTICE
- To prevent leaks, do not install the ChromaSteam3 fixture where direct contact with steam emission or water spray could occur.
- The ChromaSteam3 fixture is not intended to be installed underwater. To prevent leaks, do not install the ChromaSteam3 fixture in a location where it could become submerged.
- The ChromaSteam3 fixture is not rated for insulation contact. Insulation must be a minimum of 3” away from all sides of the ChromaSteam3 fixture assembly to prevent damage to the fixture.
Failure to use the junction box with correctly installed retention springs may result in the ChromaSteam3 fixture falling and causing injury
Installing the Fixture
To Install the Fixture:
-
Connect the ChromaSteam3 fixture’s pigtail to the 30-foot control cable or Duo cable in the junction box
(Figure 11).
IMPORTANT NOTE : Test that the fixture operates correctly prior to continuing with the following steps. -
Clean the surface of the ceiling to ensure the double-stick adhesive of the fixture bonds completely to the ceiling.
-
Peel off and discard the protective layer from the fixture’s double-stick adhesive (Figure 12).
-
Squeeze the retention springs on the back of the fixture and fit them into the junction box (Figure 13). Insert the fixture into the junction box and affix it to the ceiling, being careful not to pinch the pigtail/control cable/duo cable (note that the pigtail/control cable/duo cable is not shown in Figure 13). Press firmly around edges of the fixture to ensure adhesion to ceiling.
-
Apply a bead of silicone around the perimeter of the fixture (Figure 14) as required to create a moisture seal between the fixture and the steam room ceiling. Use tape or other means as required to keep the fixture in position as the silicone cures.
Connecting the ChromaSteam3 Fixture to the ChromaSteam3 Control Box
WARNING
- Shock Hazard. Ensure that power is turned off during installation. Turn off power at breaker panel.
- Shock Hazard. To prevent electric shock, do not remove the screws on the back of the control box. No user serviceable parts inside. Refer servicing to qualified service personnel only
At this point in the installation:
- For installation with one ChromaSteam3, the ChromaSteam3 fixture’s pigtail has been connected to one end of the 30-foot control cable (see page 8), and the other end has been routed through conduit so that it is located for connection to the control box.
- For installation with two ChromaSteam3, the longer end of Duo cable (with a yellow flag stating “To fixture”) has been routed through conduit, the ChromaSteam3 fixture’s pigtail has been connected to the longer end of Duo cable (with a yellow flag stating “To Fixture”), one end of 30-foot control cable has been located for connection to the control box. Connect the shorter end of Duo cable (with a yellow flag stating “To 30’/60’ Cable”) to the other end of the 30-foot control cable.
-
Using a Phillips-head screwdriver, remove the two cover screws from the front of the ChromaSteam3 control box (Figure 15), and remove the cover from the unit (Figure 16).
-
Insert the free end of the control cable into the control box’s LED receptacle (Figure 17).
-
Route the control cable through an empty slot in the lower portion of the control box’s housing (Figure 18).
-
Replace and secure the control box cover using the two cover screws.
Connecting the ChromaSteam3 Control Box to the Steam Generator
The final connection is made from the ChromaSteam control box (Figure 19) to an internal connector in the steam generator.
WARNING Shock Hazard. Power must be disconnected at the main electrical supply before removing the steam generator cover. For information about the steam generator, refer to the installation, operation, and maintenance manual supplied with the steam generator (also found at www.mrsteam.com/technical).
-
Remove the steam generator cover, and remove knockout on steam generator.
-
Connect the controller cord directly to the steam generator’s circuit board, Figure 20.
-
Plug the ChromaSteam3 control box power cord into a 120V grounded electrical outlet.
ChromaSteam3 Specifications
ENVIRONMENTAL RATINGS | CONTROL BOX | FIXTURE |
---|---|---|
Operating temperature: | -4 °F (-20 °C) to 140 °F (60 °C) | -4 °F (-20 °C) to |
140 °F (60 °C)
Storage temperature:| -22 °F (-30 °C) to 185 °F (85 °C)| -22 °F (-30 °C) to
185 °F (85 °C)
Humidity:| 70% max| 100%, condensing
Water resistance:| IPX5| Designed to IP67
MECHANICAL| CONTROL BOX| FIXTURE
---|---|---
Weight:| 1.9 lb (0.87 Kg)| 1 lb (0.45 Kg)
Dimensions (W x H x D):| 7 1/32” x 6 1/8” x 2 1/4”(179 mm x 156 mm x 57 mm)| 6
5/16” x 4 11/16” x 1 1/2”(161 mm x 120 mm x 38 mm)
| |
LINE INPUT| CONTROL BOX|
Input voltage:| 120VAC 50/60Hz|
LED OUTPUTS: CONTROL BOX
- 5 VDC 1.6A Max
- up to 78,000 colors
- 2 rainbow effects with smooth transition
HOMEOWNER/END-USER INSTRUCTIONS
About ChromaSteam3
Like water and heat, light is a fundamental life force and may improve your physical and mental state. The Mr.Steam ChromaSteam®3 system integrates light with steam, creating chromatherapy environments rich with color, mood, and warmth:
- ChromaSteam3 suffuses the steam shower with a spectrum of color from airy blue to sensual red.
- Vapor-sealed, low voltage LED module yield long-lasting high performance and cool operation.
- ChromaSteam3 offers a wide range of 78,000 different colors.
- ChromaSteam3 is UL listed for safety.
ChromaSteam3 Warranty
To view or download the MrSteam® Accessory Warranty and register
your product, go to: blog.mrsteam.com/wr
Operating ChromaSteam3
You can control the ChromaSteam3 LED module from within your steam room using the iSteam3 control. Select from 78,000 different colors — and control the brightness of the light — all from a simple interface.
To operate the ChromaSteam3 using iSteam3:
-
Turn on iSteam3 and wait for the iSteam3 home screen to appear.
-
Turn on the ChromaSteam fixture (Figure 21) by tapping the LIGHT BULB icon (A) and then tapping the CHROMA button (B).
-
Tap the COLOR WHEEL icon (A in Figure 22).
-
The color wheel and brightness control will appear (Figure 23). Tap anywhere in the color wheel (A) to choose the desired color. Slide the brightness control (B) left or right to choose the desired intensity of light.
-
Turn on preset colors by tapping the LED LIGHTS icon (A in Figure 24) and then scrolling through and tapping a color (A in Figure 25).
-
Turn off ChromaSteam3 by tapping the POWER icon (A in Figure 26) and then tapping the CHROMA button ( B in Figure 26).
mr.steam®
Feel Good Inc.
FOR MORE INFORMATION PLEASE CALL
Sales & Support
EAST COAST 1.800.76.STEAM
WEST COAST 1.800.72.STEAM
www.mrsteam.com
mr.steam®
Sussman-Automatic Corporation® • www.mrsteam.com •
hello@mrsteam.com
43-20 34th Street, Long Island City NY 11101 9410 S. La Cienega Blvd.,
Inglewood CA 90301
TEL: 1 800 76 STEAM FAX: 718 472 3256 TEL: 1 800 72 STEAM FAX: 310
216 2944
Products, information and specifications are subject to change without notice.
References
- MrSteam Warranty Registration
- Home | Steam Shower Generators Controls Accessories | MrSteam
- Residential Steam Shower Manuals and Specifications | MrSteam