Mounting instructions
up flat
Safety precautions
Read through the mounting/use instructions carefully before installing the
luminaire. Follow the safety precautions in these instructions closely and
keep the instructions in a safe place.
Explanation of symbols
This symbol warns you of a dangerous situation which could lead to serious
injury or even death if the instructions are not observed.
It also draws your attention to possible material damage and provides other
important information in connection with this product.
This symbol warns you of hot surfaces, which could cause burns if touched.
This symbol draws your attention to situations in which you could look
directly into the light of the LED.
This may cause an after-image effect and may result in damage to the eyes if
you look at the light directly for prolonged periods.
General safety precautions
The assembly and installation of electrical components must be car-ried out
only by qualified personnel. Repairs must be carried out only by authorised,
qualified personnel or the manufacturer.
Before performing any work on the spotlight (installation, changing the light
source, cleaning, etc.), it must be disconnected from the mains supply.
Maintain the minimum safety distance from flammable materials: 20 cm.
Caution: When used for prolonged periods, the surface of the spotlight can
become hot.
Before performing any work on the spotlight (fitting the spotlight, changing
the light source or insert, etc.), always switch the spotlight off and let it
cool for at least 30 minutes.
Product description
Thanks to the modular LED head/ body system, it is possible to combine a head,
body and base each with different surfaces.
The head can be taken off for configura-tion and maintenance; replaceable LED.
Heads with single-sided or double-sided light output are available; luminous
power 18 W or 26 W.
Lighting effect can be changed through optional inserts; dichroiticcolour
filter can be additionally inserted.
Adjustable thanks to the heat-insulated carbon rod. As an option, the head can
be secured against turning.
up-Version
LED wall-mounted luminaire with high base incl. power supply unit (converter)
for mounting on a solid wall; connection to 230 V.
Externally dimmable by trailing-edge phase-cut dimmer or by gesture-controlled
„touchless control“ on the head.
flat-Version
LED wall-mounted luminaire with flat base for mounting on a hollow ceiling
box; connection to an external constant-voltage source (converter).
Externally dimmable (depending on power supply unit) or by gesture-controlled
„touchless control“ on the head.
Assembling the body
Sento soffitto due up
Installation
Cut the mains cable to a length of 5 cm and strip the insulation from the ends.
Place the mounting plate over the power outlet and against the ceiling, and
turn it until the elongated holes are aligned as required.
Mark the positions where the holes are to be drilled.
Check the routing of the power cables.
Drill two 6 mm diameter holes, push in the rawlplugs so that they lie flush
and screw on the mounting plate (screws and rawlplugs are included in the
scope of delivery).
Ensure that the screws finish flush with the mounting plate. Using a
screwdriver, open the flap in the middle of the converter.
Lock the converter into the mounting plate so that it is fitted flush.
At the same time, guide the ends of the mains cable through the converter
opening. Connect the ends of the mains cable to the converter terminals in
accordance with the diagram.
Caution:
Before fitting, disconnect all current-carrying lines from the mains supply.
Close the flap of the converter.
Undo the cover by turning it anti-clockwise and let it hang on the luminaire
stem.
Do not remove the protective film yet.
Insert the plug of the luminaire body into the sockets of the converter. Lay
the cable in the recess of the converter. Do not trap the cable.
Screw the luminaire body onto the two spacers of the mounting plate using the
screws (Allen) provided.
Removing the protective film Carefully guide the cover over the luminaire
stem.
Turn clockwise and lock in place.
The body is now fully assembled.
To assemble the head: See „As- sembling the head“. For inspection purpose
removable (only for white and black body).
Sento soffitto due flat
Installation with Occhio converter
To connect an external Occhio converter :
Correctly connect the converter to the mains cable.
Guide the sockets for the LED connection cables to the outside thr ough the
hollow ceiling/plastering box. Occhio BUS
By connecting the Occhio BUS cable, it is possible to control both heads
synchronously using „touchless control“.
To do so, the two cables marked with BUS are connected to one another using a
suitable terminal.
Other cables are connected as specified above.
Caution:
Before fitting, disconnect all current-carrying lines from the mains supply.
Installation with converter
(external manufacturer)
Connecting a converter from an external manufacturer (see supplementary sheet
for the converter): Connect the converter to the mains cable as shown in the
wiring diagram. Connect the cable with the LED socket to the converter.
Observe the technical instructions of the particular manufacturer.
Black = positive pole, white = negative pole
Guide the socket of the LED extension cable to the outside through the hollow
ceiling/plastering box. Occhio BUS
By connecting the Occhio BUS cable, it is possible to control both heads
synchronously using „touchless control“. To do so, the two cables marked with
BUS are connected to one another using a suitable terminal. Other cables are
connected as specified above.
Caution:
Before fitting, disconnect all current-carrying lines from the mains supply.
Screw the mounting plate to the hollow ceiling box. As you do so, guide the
socket of the LED connection cable through the opening.
Ensure that the screws finish flush with the mounting plate.
Undo the cover by turning it anticlock-wise and let it hang on the luminaire
stem. Connect the plug of the body to the sockets of the LED connection
cables. Guide the cable with the plug connection back into the hollow ceiling
box.
Screw the luminaire body onto the mounting plate using the screws (Allen)
provided. Remove the protective film.
Carefully guide the cover over the luminaire stem.
Turn clockwise and lock in place.
The body is now fully assembled.
To assemble the head: See „Assembling the head“. For inspection purpose
removable (only for white and black body). Removing the carbon rod
Pull the carbon rod off forwards. Fitting the carbon rod
Orientation as illustrated.
Fit the carbon rod.
The body is now fully assembled.
To assemble the head: See „Assembling the head“. Fixing ring (optional)
Orientation as illustrated. Before mounting, undo the grub screw.
Fit the fixing ring and, if necessary, secure it against turning using a
hexagonkey. The body is now fully assembled. To assemble the head:
See „Assembling the head“.
Appendix
Care instructions
Always allow the luminaire to cool down before cleaning.
To clean the luminaire, use a dry microfibre cloth or the Occhio cleaning
agent.
Information & contact
Your Occhio specialist retailer will gladly answer any other questions
www.occhio.de
info@occhio.de
Technical data
Technical data – luminaire
Product designation | Occhio Sento soffitto due |
---|---|
up version | Head dia. 123 mm, base dia. 108 mm, H 36 mm |
flat version | Head dia. 123 mm, base dia. 88 mm, H 8 mm |
Length | 300 / 400 / 600 / 800 / 1000 / 1250 mm |
Head turning range | 360° without stop |
Head swivel range | 300-600 mm 120° / 800-1250 mm 90° |
Body turning range (optional) Safety class | 180° with stop |
Connection | up version: 2 flat version: 3 |
Power supply unit | up version: 230 V AC, 50 Hz |
flat version: 48 V DC, min. 22 W per 18 W head, min. 30 W per 26 W head
Dimming| up Version: Integrated flat Version: External
Materials| Via »touchless sensor« integrated in the
head or: up version: by trailing-edge phase-cut dimmer (for a list of
compatible dimmers, visit www.occhio.de/ dim) flat
version: With suitable power supply unit
Light source| Luminaire: Aluminium, chrome-plated, painted or anodised steel,
plastic
Inserts: Glass, optical plastic
LED power| 18 W/26 W depending on the head
Permitted operating conditions| Max. 30°C (for indoor use only)
Test symbols|
Disposal| Dispose of at the local waste disposal site.
The power supply unit and the head are recyclable and RoHS-compliant. Do not
dispose of with household waste.
Occhio GmbH
Wiener Platz 7
81667 München
Fon +49-89-44 77 86 30
Fax +49-89-44 77 86 39
info@occhio.de
www.occhio.de 2021 | 12 | 14 MA-56709-Sento-
soffitto-due
Irrtümer und technische Änderungen vorbehalten.
Subject to errors and technical change.
References
- Occhio Official Website | We create a new culture of light
- Occhio Official Website | We create a new culture of light
- Willkommen bei Occhio | Occhio
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>