saxby lighting 39166 Knight Spotlight Instruction Manual

June 12, 2024
saxby lighting

saxby lighting 39166 Knight Spotlight

saxby-lighting-39166-Knight-Spotlight-product

Product Information

  • Product Name: Knight Spotlight
  • Model Number: 39166
  • Bulb Type: 35W GU10 Mains Halogen
  • Manufacturer: Saxby Lighting
  • Manufacturer Address: UK Manufacturer: BH17 7BY, EU Manufacturer: Brilliant AG, Brilliantstrasse 1, D-27442 Gnarrenburg
  • Website: www.saxbylighting.com
  • Double Insulated (Class 2): Yes
  • Voltage: 220-240V 50Hz a.c.
  • IP Rating: 44

Product Usage Instructions

  1. Before changing lightbulbs or cleaning, always switch off the power supply to ensure safety.
  2. If the glass shade of the bulb becomes cracked or damaged, it must be replaced immediately. Do not use the fitting without the glass shade in place. Replace the cracked shade.
  3. The light fitting does not require connection to an Earth circuit as it is double insulated (class 2).
  4. Layout:
    • Zone 1: Within 2.25m
    • Outside zones: Within 0.6m
    • Zone 2: Within 0.2m
  5. During installation, carefully note the position of each set of wires.
  6. Wiring:
    • SUPPLY NEUTRAL: Connect the neutral wire of the light fitting.
    • SWITCHED LIVE: Connect the switched live wire of the light fitting.
    • CHECK THAT…: Ensure the following connections are correct.
    • LIGHT FITTING BLUE (N): Connect to the neutral wire.
    • LIGHT FITTING BROWN (L): Connect to the switched live wire.

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.

Warnings

  • This light fitting is double insulated (class 2) and does not require connection to an Earth circuit
  • Please read these instructions carefully before commencing any work.
  • This unit must be fitted by a competent and qualified electrician.
  • Install in accordance with IEE Wiring regulations and current Building Regulations.
  • To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
  • This light fitting should be connected to a fused circuit.
  • If replacing an existing fitting, make a careful note of the connections.
  • Always use the correct type and wattage bulb. Never exceed the wattage stated.
  • When changing a bulb, always switch off at the mains and allow the old bulb to cool down before handling. Dispose of used bulbs carefully and responsibly. This product is suitable for dimming when used in conjunction with a dimmable lamp. Please ensure verification of dimming abilities with the lamp manufacturer prior to use.
  • Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

Specification

  • Voltage: 220-240V 50Hz a.c.
  • Lamp: 1 x Max. 35W GU10
  • IP rating: 44

Layout

  • Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the junction box and the light fitting
  • Avoid locating any cables in positions that would cause a hazard. Position cables and junction boxes (not supplied) away from areas where they may be at risk of being cut, trapped, or damaged
  • The main supply cable must have a minimum cross-sectional area of 1.0mm.
  • This product must be mounted out of arm’s reach.
  • This product has special protection against the ingress of moisture and is IP44 rated.

This product is suitable for use in Zone 2 and outside Zones of a bathroom. See diagram. If this unit is being fitted in a room containing a bath or shower, a 30mA RCD must be used, in accordance with IEE regulations.

Spotlights give a concentrated beam of light and must not be positioned any closer than 0.2M (20cm) to the illuminated surface.

Installation

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.

  • Undo the screws holding the fixing bracket in place and set aside
  • Hold the product in place and mark the position of the holes.
  • Ensure the ceiling is capable of holding the weight of the product. Take care to avoid damaging any concealed wiring and pipes. The correct fixings should be used. Ensure there is a joist at the point of fixing to support the weight of the product.
  • Fix the ceiling bracket into position.

Wiring

Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to the connection block inside the product in the following way: This unit is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together and well-insulated with good-quality insulation tape. This is to ensure earth continuity throughout your property.

saxby-lighting-39166-Knight-Spotlight-fig- \(3\)

Check that..

  • You have correctly identified the wires
  • The connections are tight
  • No loose strands have been left out of the connection block.

Commissioning

  • Replace the cover on the terminal block.
  • Lift the product into place and align the screw holes up with the holes on the bracket.
  • Using the supplied allen key, tighten the screws to secure. Take care not to trap any wiring.
  • Replace fuse or circuit breaker and switch on. Your light is now ready for use.

Fitting/replacing bulbs

  • When changing a bulb, always switch off at the mains and allow the bulb to cool before handling. Used bulbs should not be disposed of with household waste. Please recycle where facilities exist.
  • Always use the correct type and wattage bulb. Using the incorrect wattage bulb will damage the product.
  • Use a soft cloth to handle bulbs, avoid directly touching the bulbs as this will shorten their life.
  • Unscrew the shades anticlockwise. Remove bulb by turning a quarter turn anticlockwise and pulling out.
  • Push the bulb gently into the lampholder and twist a quarter turn clockwise to engage pins. Replace the shade by gently screwing it on.
  • We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
  • Glass parts – Wipe clean with a damp cloth. Do not use abrasive materials as these will damage the finish.

Recycling advice

  • Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
  • Check with your Local Authority or retailer for recycling advice.

Safety information

For your safety, always switch off the power supply before changing lightbulbs, or cleaning.

  • This bulb is protected by a glass shade. This part must be replaced immediately should the glass shade become cracked or damaged. This fitting must not be used without the glass shade in place.

UK Manufacturer: BH17 7BY

EU Manufacturer:
Brilliant AG, Brilliantstrasse 1, D-27442 Gnarrenburg
www.saxbylighting.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

saxby lighting User Manuals