SUSSEX CDIV Calibre Diverter
Product Information
- Product Name: Calibre Diverter
- Model: Stud 70
- Product Code: CDIV
- Manufacturer: sussextaps.com.au
- Standards Compliance: AS/NZS 3718:2005 LIC. 20081
- Recommended Working Water Pressure: 300-500 kpa
- Maximum Water Temperature: 65 deg.c
Product Usage Instructions
- Prior to installing, calculate the finished wall thickness to ensure the Dress Ring and Handle will fit at the final assembly.
- To seal the wall around the Mixer Body, apply an appropriate silicone sealant to ensure the wall is waterproof.
- Fit the Dress Ring onto the Diverter Body until it reaches the wall covering.
- Choose the desired position for the Handle and align it accordingly.
- Tighten the Set Screw using the provided 2.5mm Allen Key. Ensure it is tightened well.
- To complete the installation, test the function of the Diverter.
Note : Tapware installation should be carried out by a Licensed Plumber in accordance with AS/NZS 3500:2003. The combined wall thickness should not exceed 30mm. The rough-in plumbing should be done before installing the Diverter.
INSTRUCTIONS
Diverter Connection
Product code
- CDIV Diverter
Rough in plumbing
-
Prior to installing, calculate the finished wall thickness to ensure the Dress Ring and Handle will fit at the final assembly.
-
The Diverter Body is supplied with a plastic cover for protection during Plastering and Tiling.
-
Fix a Nogging or a purpose built frame between the Wall Studs.
-
Set the Nogging 28 to 35mm back from the front of the stud as shown.
-
Using the screws provided, fix the Diverter Body to a the Nogging or purpose built frame.
-
All ports are marked on the shoulder of the Diverter body to indicate the appropriate connections.
-
Flush all water feed lines. All lines must be free from any dirt and debris before connecting.
NOTE : The Mixed water from the tapware can only be connected to the port marked “Mixed IN” -
After all water connections are made, check water flow is being diverted between Outlet 1 and Outlet 2.
-
Check all connections for any water leaks.
-
Store remaining parts in a safe place until wall coverings have been completed and final fit-off is required (Dress finishing)
Dress finishing
- Apply the appropriate silicone to seal the Wall around the Mixer Body ensuring the wall is waterproof.
- Fit the Dress Ring onto the Diverter Body until it reaches the Wall covering.
- Fit and align Handle to chosen position and tighten Set screw using the 2.5mm Allen Key provided. (Tighten well)
- Test function to complete installation.
sussextaps.com.au
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS
3500:2003 Recommended working water pressure 300-500 kpa. Maximum water
temperature is 65 deg.c Copyright © Sussex Taps.