Product code

  • VBM Basin mixer
  • VEBM Extended basin mixer 90mm outlet
  • VEBM120 Extended basin mixer 120mm outlet
  • VMBM Medium basin mixer 90mm outlet
  • VMBM120 Medium basin mixer 120mm
  • VBMSS Basin mixer 316 S/S

Installation guidelines

SUSSEX-VEBM120-Extended-Basin-Mixer-
fig-1

  • The Mixer is supplied assembled, only the Fixing nut and the Brass Clamp need to be removed.
  • Decide if the Optional Base Flange is to be used.
  • If using the Optional Base Flange discard the smaller Base O Ring.
  • Add the base Flange to base of Mixer and attach the Flexible Hoses to the Mixer Hose extensions.
  • In some cases the Flexible Hoses may need to be fed through from under the mounting surface and then attach.
  • Once the Flexible Hoses have been secured, lower the Mixer onto the mounting surface.
  • Working from underneath the mounting surface fit Clamp and Fixing Nut.
  • Before fully securing the Mixer ensure that the Base O Ring is intact and the Mixer is centered over the mounting surface hole.
  • The Mixer mounting surface must be completely water-tight.
  • Connect the Hot and Cold Flexible hoses to the corresponding 1/2”BSP water feed lines.
  • The 1/2” connection of the Flexible hoses have a conical seal, ensure the mating threads are cut square and burr free.
  • Isolating stop valves are recommended with all installations (not supplied).
  • Ensure all fittings and connections are water-tight.

Note : Optional Base Flange must be used when the clearance hole for mounting the Mixer exceeds 35mm. If the mounting hole clearance exceeds 45 mm a custom made Base flange will be required.

Plumber note

  • On-site testing using higher water pressures must be conducted with the Mixer in the closed position. (STATIC TEST)
  • Under no circumstances is the Mixer to be opened when exceeding the maximum stated water pressure.
  • At the completion of testing, do not relieve any high water pressure by operating the Mixer.
  • Exposing the internals of the Mixer Car tridge to higher than specified water pressures will void the manufacturers warranty.

Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003 Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c Copyright © Sussex Taps.