TRAVIS INDUSTRIES 96400716 Large Flush Wood Face Instruction Manual

June 12, 2024
TRAVIS INDUSTRIES

TRAVIS INDUSTRIES 96400716 Large Flush Wood Face

TRAVIS INDUSTRIES 96400716 Large Flush Wood Face-
product

Product Information

This user manual provides instructions for the installation of the Large Flush Wood Face for the specified models:

  • Lg. Flush Wood Rect. Faces
  • Lg. Flush Wood Discontinued Faces
  • Lg. Flush Wood Arch. Faces

The product codes for the available face options are:

  • Wilmington Black – 96400293
  • Arched Black – 96400713
  • Arched Charcoal – 96400714
  • Wilmington Black – 96400294

The Large Flush Wood Face is compatible with the following models:

  • Large Flush Wood Hybrid-Fyre Insert with 1-Piece Panel
  • Large Flush Wood Nex-Gen
  • Large Flush Wood Nex-Gen Hybrid

Product Usage Instructions

  1. Before installing the face, ensure that the insert is in place, attached to the flue, and the surround panel is in place.
  2. Remove the air control rod.
  3. Connect the rheostat wires and route the power cord through the hole in the surround panel.
  4. Attach the face by following the provided diagram. Ensure that the bypass rod is fully pushed in.
  5. Attach the bypass ring to the bypass rod.
  6. Remove the wooden knob from the existing air control rod and attach it to the provided air control rod. Re-attach to the air control assembly.
  7. Remove and discard the stock extender.
  8. Ensure that all wiring is inserted into the cavity between the insert and the fireplace to prevent damage.

For more detailed instructions, refer to page 2 of the user manual with the document code 17601688 – 12/23/2022.

Lg. Flush Wood Rect. Faces Lg. Flush Wood Arch. Faces
Metropolitan Black – 96400716 Universal Face – 96400756 Arched Black –

96400713 Arched Charcoal – 96400714 Wilmington Black – 96400294
Lg. Flush Wood Discontinued Faces
Wilmington Black – 96400292| Wilmington Black – 96400293|  |

Compatibility

  • Large Flush Wood Hybrid-Fyre Insert with 1-Piece Panel
  • Large Flush Wood Nex-Gen
  • Large Flush Wood Nex-Gen Hybrid

Packing List

  • Face (not shown)
  • Air Control Rod
  •  Bypass Ring

Installation

  1. Before installing the face, make sure the insert is in place, attached to the flue, and the surround panel is in place. Remove the air control rod (see “a” below).
  2. Connect the rheostat wires and make sure the power cord is routed through the hole in the surround panel (see “b” below).

Large Flush Wood Face Installation

  1. Attach the face as shown below (see “a” below). First ensure that the bypass rod is fully pushed in.

  2. Attach the bypass ring to the bypass rod (see “b” below).

  3. Remove the wooden knob from the existing air control rod and attach it to the air control rod provided.
    Re-attach to the air control assembly (see “c” below).

  4. Remove and discard the stock extender.

WARNING:
Make sure all wiring is inserted into the cavity between the insert and the fireplace.
Failure to do this may cause the wiring to become damaged.

© Travis Industries, Inc.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TRAVIS INDUSTRIES User Manuals

Related Manuals