Product Information
This user manual provides instructions for the installation of the Large Flush Wood Face for the specified models:
- Lg. Flush Wood Rect. Faces
- Lg. Flush Wood Discontinued Faces
- Lg. Flush Wood Arch. Faces
The product codes for the available face options are:
- Wilmington Black – 96400293
- Arched Black – 96400713
- Arched Charcoal – 96400714
- Wilmington Black – 96400294
The Large Flush Wood Face is compatible with the following models:
- Large Flush Wood Hybrid-Fyre Insert with 1-Piece Panel
- Large Flush Wood Nex-Gen
- Large Flush Wood Nex-Gen Hybrid
Product Usage Instructions
- Before installing the face, ensure that the insert is in place, attached to the flue, and the surround panel is in place.
- Remove the air control rod.
- Connect the rheostat wires and route the power cord through the hole in the surround panel.
- Attach the face by following the provided diagram. Ensure that the bypass rod is fully pushed in.
- Attach the bypass ring to the bypass rod.
- Remove the wooden knob from the existing air control rod and attach it to the provided air control rod. Re-attach to the air control assembly.
- Remove and discard the stock extender.
- Ensure that all wiring is inserted into the cavity between the insert and the fireplace to prevent damage.
For more detailed instructions, refer to page 2 of the user manual with the document code 17601688 – 12/23/2022.
Lg. Flush Wood Rect. Faces | Lg. Flush Wood Arch. Faces |
---|---|
Metropolitan Black – 96400716 Universal Face – 96400756 | Arched Black – |
96400713 Arched Charcoal – 96400714 Wilmington Black – 96400294
Lg. Flush Wood Discontinued Faces
Wilmington Black – 96400292| Wilmington Black – 96400293| |
Compatibility
- Large Flush Wood Hybrid-Fyre Insert with 1-Piece Panel
- Large Flush Wood Nex-Gen
- Large Flush Wood Nex-Gen Hybrid
Packing List
- Face (not shown)
- Air Control Rod
- Bypass Ring
Installation
- Before installing the face, make sure the insert is in place, attached to the flue, and the surround panel is in place. Remove the air control rod (see “a” below).
- Connect the rheostat wires and make sure the power cord is routed through the hole in the surround panel (see “b” below).
Large Flush Wood Face Installation
-
Attach the face as shown below (see “a” below). First ensure that the bypass rod is fully pushed in.
-
Attach the bypass ring to the bypass rod (see “b” below).
-
Remove the wooden knob from the existing air control rod and attach it to the air control rod provided.
Re-attach to the air control assembly (see “c” below). -
Remove and discard the stock extender.
WARNING:
Make sure all wiring is inserted into the cavity between the insert and the
fireplace.