Energizer V23-00208 3-Phase Kit CT Instruction Manual

June 12, 2024
Energizer

Energizer - logo

HOMEPOWER
V23-00208 3-Phase Kit CT
Instruction ManualEnergizer V23 00208 3 Phase Kit
CT

3-Phase Kit – (CT)
Installation Instructions

CONTENTS

Energizer V23 00208 3 Phase Kit CT - CONTENTS

INTRODUCTION

The 3-Phase Kit is used to measure electrical energy data across multiple phases of both consumption and generation and report it back to the Energizer Homeowner system.
There is provision within this kit to measure energy data from up to 3 phases of consumption by clipping a CT sensor on each phase between the loads and the grid, and up to 3 phases of generation from Solar PV systems by clipping a CT
sensor on each phase between the PV inverter and the loads.
This is accompanied by voltage references measured via the digital meter(s).
If the Solar PV system is only Single Phase then a digital meter is not required for capturing “Generation” as this data may be captured by the CT (for PV) supplied with the Main Unit (HP-6M).

STEP 1 – WIRING
Power digital meter(s) and change settings accordingly. Determine the system configuration from the list below, and follow the corresponding line diagram on the reverse side to complete wiring. Energizer V23 00208 3 Phase Kit CT -
CONTENTS1

Once you have completed the wiring, proceed to step 2.

Energizer V23 00208 3 Phase Kit CT - supleryEnergizer V23 00208 3 Phase Kit CT -
suplery1

STEP 2 – CODE & CT

Energizer V23 00208 3 Phase Kit CT - STEP 2

  1. Press to enter the “code” screen.
  2. Press to edit code from “600” to “701” to enter men
  3. Press to change the last digit from “0” to “1”.
  4. Press twice to move to the first digit.
  5. Press to change the first digit from “6” to “7”.
  6. Press twice to get to settings, you will see “ ”.
    Note: The numbers will reset to “600”.

Energizer V23 00208 3 Phase Kit CT - STEP3

  1. Press to edit “CT” value.
  2. Toggle between to set value to “20”.
  3. Press to exit.
    Note: “20” is the ratio for the CT’s provided in this kit.
    If you are using 3rd party CT’s you may need to adjust this value.

STEP 3 – PROTOCOL & ADDRESS

Energizer V23 00208 3 Phase Kit CT - STEP4

  1. Press twice to get to “Prot” screen.
  2. Press to edit value.
  3. Press to scroll through to find “n.1”.
  4. Press to exit.

Energizer V23 00208 3 Phase Kit CT - STEP5

  1. Press to get to “Addr” screen.

  2. Press to edit value.

  3. Toggle between to edit value.
    set Consumption meter to “1” / Generation meter to “2”.

  4. Press to keep value.

  5. Press   to exit.

STEP 4 – BAUD RATE

Energizer V23 00208 3 Phase Kit CT - BAUD RATE

  1. Press to get to “bAud” screen.
  2. Press to set value.
  3. Press to scroll to “2.400”.
  4. Press to exit.

STEP 5 – INSTALLER APP
Energizer V23 00208 3 Phase Kit CT - INSTALLER APPEnergizer V23 00208 3 Phase Kit CT - INSTALLER APP
1 Select whether you are using: 1 x Digital Meter + 1x CT or 2 x Digital MetersEnergizer V23 00208 3 Phase Kit CT -
INSTALLER APP2

Input Ratio: Set Value to “20”
Note: “20” is the ratio for the CT’s provided in this kit. If you are using 3rd party CT’s you may need to adjust this value.

Energizer V23 00208 3 Phase Kit CT - Review & Test© 2021 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by 8 Star Energy Pty Ltd. All other brand names are trademarks of their respective owners. Neither 8 Star Energy Pty Ltd nor Energizer Brands, LLC is affiliated with the respective owners of their trademarks.Energizer -
logo