Features

  • Universal AC input / Full range

  • Withstand 300VAC surge input for 5 seconds

  • 300% peak power capability

  • Built-in constant current limiting circuit

  • Fanless design, Cooling by free air convection

  • Protections: Short circuit / Overload / Over voltage /
    Over temperature

  • Built-in remote sense function

  • Withstand 5G vibration

  • Prating altitude up to 5000 meters(Note.5)

  • Output votage adjustable +15%(Avg.)

  • 1U low profile 38mm

  • 5 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Diagnostic or biological facilities
  • Test or measurement systems
  • Telecommunication equipment

GTIN CODE

MW Search: https:/www.meanwell.com/serviceGTIN.aspx

Description

HRP-150N3 series is a 150W single output AC/DC ultra-high peak power supply. This series operates at 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by free air convection, working for the temperature up to 70°C without cover. Moreover, HRP-150N3 can provide 300% short-duration peak power for motor applications and electromagnetically loads requiring much higher power during start-up.

Model Encoding

Model Encoding

SPECIFICATION

MODEL| HRP-150N3-12| HRP-150N3-24| HRP-150N3-36| HRP- 150N3-48
---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 13A| 6.5A| 4.3A| 3.3A
CURRENT RANGE| 0 ~ 13A| 0 ~ 6.5A| 0 ~ 4.3A| 0 ~ 3.3A
RATED POWER| 156W| 156W| 154.8W| 158.4W
RIPPLE & NOISE (max.) Note.2| 120mVp-p| 150mVp-p| 200mVp-p| 240mVp-p
VOLTAGE ADJ. RANGE| 10.2 ~ 13.8V| 21.6 ~ 28.8V| 28.8 ~ 39.6V| 40.8 ~ 55.2V
VOLTAGE TOLERANCE Note.3| ±1.5%| ±1.5%| ±1.5%| ±1.5%
LINE REGULATION| ±0.3%| ±0.2%| ±0.2%| ±0.2%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 3000ms, 50ms/230VAC        3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC        16ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.4| 85 ~ 264VAC       120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC        PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 88%| 88%| 89%| 89%
AC CURRENT (Typ.)| 1.7A/115VAC      0.9A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC       70A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| OVERLOAD| Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover
Constant current limiting for output power >330% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 14.4 ~ 16.8V| 30 ~ 34.8V| 41.4 ~ 48.6V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -50 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.04%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.5| 5000 meters
SAFETY & **EMC (Note 6)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class B
Radiated| BS EN/EN55032| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact
RF field| BS EN/EN61000-4-3| Level 3, 10V/m
EFT/ Burst| BS EN/EN61000-4-4| Level 3, 2KV
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3, 10V
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m
**
Voltage Dips and Interruptions| ** BS EN/EN61000-4-11| 95% dip 0.5 periods, 30% dip 25 periods,95% interruptions 250 periods
OTHERS| MTBF| 1706.0K hrs min.  Telcordia TR/SR-332 (Bellcore) ; 222.8K hrs min.  MIL-HDBK-217F (25℃)
DIMENSION| 1599738mm (LWH)
PACKING| 0.54Kg; 24pcs/12.96Kg/0.9CUFT
NOTE*| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance : includes set up tolerance, line regulation and load regulation.4. Derating may be needed under low input voltages. Please check the derating curve for more details.5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMl testing of component power supplies.” (as available on http://www.meanwell.com)※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Block Diagram

Derating Curve

AMBIENT TEMPERATURE (C)
Derating Curve

Output Derating VS Input Voltage

INPUT VOLTAGE (V) 60Hz
Output Derating

Function Manual

Peak Power

PoX t+ Py x (T-)
T ated
Duty = x100% = 35%
t =5sec

Pav: Average output power (W)
Pg : Peak output power (W)
Pasc: Non-peak output power (W)
Praea: Rated output power(W)
t: Peak power width(sec)
T: Period(sec)
Peak Power

Peak output power (W)
Function Manual

For example (12V model):

Vin =200V Duty_max =5% P.= P, = 156W P,.= 450W t<5sec T2 552 > 100sec TP, – tP, P..< — < 140W

Remote Sense
The remote sensing compensates voltage drop onthe load wiring up to 0.5V.
Remote Sense

NC NC +S
NC NC -S

Mechanical Specification

Dimensions

Terminal Pin No. Assignment:

Pin No. Assignment Pin No. Assignment
1 AC/L 4,5 DC OUTPUT -V
2 AC/N 6,7 DC OUTPUT +V
3 FG

Connector Pin No. Assignment (CN100) : HRS DF11-6DP-2DSA

Pin No. Assignment Mating Housing Terminal
1 -S HRS DF11-6DSor equivalent HRS DF11-**SCor equivalent
2 +S
3~6 NC

Installation Manual

Please refer to: http://www.meanwell.com/manual.htm|

File Name: HRP-150N3-SPEC 2022-03-03

Symbols
Symbols
Symbols

Documents / Resources

| MEAN WELL H150W Ultra-High Peak Power Supply [pdf] Instruction Manual
H150W Ultra-High Peak Power Supply, H150W, Ultra-High Peak Power Supply, High Peak Power Supply, Peak Power Supply, Power Supply, Supply
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals