SAFETY INFORMATION

integral LED ILGDA006 Buried Ground Light - Icon|
---|---

  1.  A – Follow Instruction Sheet to ensure safe and reliable operation. Retain for future reference.

  2. Products should be installed by a qualified Electrician in accordance with International Wiring Regulations.

  3.  B – Switch off mains supply before installation. Isolate from mains supply before any maintenance.

  4.  Integral LED accepts no responsibility for modified products.

  5.  Integral LED Adaptors, Connectors and Track luminaires must only be used with the Track system for whichthey have been designed.

  6. If Dimmer is installed it must be specifically rated as suitable and compatible with the equipment used.

  7. Touching a reflective surface must be avoided.

  8. Check that the rating on the product label conforms to the mains supply.

  9.   C – For indoor use only.

  10.  D – Class I – This product should be Earthed.

  11. E – Class II – This product does not require Earthing.

  12.  F – Class III – SELV Luminaires to be used with Double Insulated, Extra Low Voltage, Safety Isolating Transformers or LED drivers.

  13.  Do not interconnect Class III products with Class I or Class II.

  14.  Metal enclosed, Class II and Class III products must not be mounted in contact with or close to Earthed metalwork.

  15.  G / H – Luminaires not suitable for direct mounting on/in normally flammable surfaces.

  16. I – Unless otherwise marked, products are IP20 (ordinary). Do not operate in damp or corrosive situations. If the luminaire is to be exposed to dust or moisture the appropriate IP(XX) rated luminaire shouldbe used.

  17. Use only the correct replacement lamp as indicated on the product label.

  18.  J – Class II product earth wire continuity terminal

  19.  K – Emergency Luminaires – Do not switch off UN-switched mains supply after installation. If interruption is unavoidable, the batteries must be disconnected or damage to the batteries or the lamp may occur. Testing – Switch on the mains supply and  heck that the charge indicator (LED) is ON. Leave the luminaire on continuous charge for 24 hours. Simulate mains failure and check that the lamp operates for 3 hours. If full duration of 3 hours is NOT achieved, repeat the charge/discharge cycle as battery  acks may have dischargedin stock and will require conditioning.

  20.  L – Not suitable for covering with thermally insulating material.

  21. Luminaire should be cleaned by using a soft damp soapy cloth. Do not use solvents.

  22.  M – This electrical product MUST be recycled in accordance with WEEE Directive.

  23. N – Dimmable.
    Dimming Compatibility : It is the responsibility of the Buyer (or its appointed specifier, or qualified electrical installer) to ensure compatibility between Seller’s Goods being installed and the dimming switch (or dimming system) intended to control the Goods. Under no circumstances shall the Seller be held responsible for such incompatibility issues.

  24. O – Risk of Electric Shock.

  25. P – Observe minimum and maximum ambient operating temperatures of the device as specified in the datasheet and/ or instruction manual.

  26. Q – This product contains a light source of energy efficiency class . Unless marked, products are classed as per the official energy rating label on the packaging.

integral LED ILGDA006 Buried Ground Light - Icon 2integral Logo Warranty/ Technical
& contact information
are all available at
www.integral-led.com

Documents / Resources

| integral LED ILGDA006 Buried Ground Light [pdf] Instruction Manual
ILGDA006 Buried Ground Light, ILGDA006, Buried Ground Light, Ground Light, Light
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

integral LED User Manuals

Related Manuals