WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation may void the warranty.
WARNING
- Please read the manual carefully, especially the safety instructions, and make sure you understand them fully before using the product. Only use the equipment for the purposes specifically intended by the manufacturer. Carefully follow the instructions on operation, maintenance and repair.
- Not intended for use in swimming pools.
- Do not operate the cleaner when there are people in the spa.
- This Cleaner is not suitable for use by children and people with reduced physical, sensory or mental capabilities or inexperienced people who are not familiar with the product. Children should be supervised to ensure that they do not play with the appliance, even when it is not in operation.
- Operators who perform maintenance must be fully conversant with its special features and safety regulations. Before using the cleaner, carefully read the operating manual and make sure you understand the instructions.
- Only use original spare parts, do not change the design of the Cleaner, do not remove, bypass or tamper with the safety devices installed. The manufacturer shall not be held liable if non-original spare parts are used. Failure to comply with this requirement may seriously endanger the health and safety of people.
- Ensure the cleaner is turned off before performing any adjustment or maintenance that the user is authorized to perform. Cleaning and maintenance must not be performed by children.
- Do not use the cleaner if the top cover or brushes are damaged.
- Never use and recharge the cleaner in explosive and/or flammable environments.
- Only use the battery charger supplied by the manufacturer. Improper use may cause electric shocks, overheating or leakage of corrosive liquids from the battery.
- If any liquid leaks, wash the cleaner with water/neutraliser; in case of contact with eyes, seek medical attention. Liquid ejected from the battery may cause irritation or burns.
- If the battery charger is damaged, have it replaced by the manufacturer or an authorized Fluidra dealer. DO NOT attempt to service the battery charger. A damaged cord can lead to contact with live parts.
- The appliance is not a toy for children.
- The product contains magnets and components that emit electromagnetic fields. The magnets and electromagnetic fields can interfere with pacemakers, defibrillators and other medical devices. Keep a safe distance between the medical device and the product. Consult your doctor or the manufacturer of the medical device for specific information about it. If you think that the product is interfering with a pacemaker, defibrillator, or any other medical device, stop using the product starting from the distance at which you feel interference.
- Do not smoke around, or allow the cleaner to be near sparks or flames. The batteries can generate gases which could possibly ignite.
- Do not expose cleaner to fire or excessive temperature. Exposure to fire or temperature above 265°F (130°C) may cause explosion.
- If at any time you detect any physical damage to the cleaner chassis, such as swollen or cracked casing, STOP and do not continue discharging or charging the battery.
- Never attempt to disassemble a battery pack. A battery can produce a short circuit causing severe burns. Avoid contact between any wires or metal items that could cause sparking and short circuit the battery. If a battery leak occurs, avoid any contact with the leaking fluids and place the cleaner in a plastic bag. Wear complete eye protection, gloves and protective clothing when disposing of cleaner. If leaking fluids come in contact with skin and clothing, wash immediately with plenty of soap and water. If leaking fluids come in contact with eyes, do not rub eyes, immediately flush eyes with cool running water for at least 15 minutes and do not rub them. Seek medical attention as soon as possible.
- Do not use a battery operated appliance that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion, or risk of injury.
Battery Life & Disposal of Li-Ion Batteries
- Regulations and laws pertaining to the recycling and disposal of Li-Ion batteries vary from country to country as well as by state and local governments. You should check the laws and regulations where you live.
- There are a number of facilities that recycle Li-Ion batteries. The Rechargeable Battery Recycling Corporation’s web site, www.rbrc.org, is an excellent source for finding a facility to handle these types of batteries. If you are not sure if your waste facility can handle Li-Ion batteries, contact them and verify if they are permitted or not.
- Remember that before any type of disposal the batteries should be discharged completely. Tape the cleaner charging contacts with electrical tape and package so as to prevent contacts accidentally coming together at any time
- This cleaner contains a maintenance-free, rechargeable lithium ion battery pack, which must be disposed properly. Recycling is required.
Battery Charger
Use ONLY the detachable supply unit provided with this appliance
The battery charger must be connected only to a supply circuit that is
protected by a ground-fault circuit interrupter (GFCI). Contact a qualified
electrician if you cannot verify that the circuit is protected by a GFCI. This
GFCI should be tested on a routine basis. To test the GFCI, push the test
button. The GFCI should interrupt power. Push reset button. Power should be
restored. If the GFCI fails to operate in this manner, the GFCI is defective.
If the GFCI interrupts power to the battery charger without the test button
being pushed, a ground current is flowing, indicating the possibility of an
electrical shock. Do not use the battery charger. Disconnect the battery
charger and contact the manufacturer for assistance.
SAVE THESE INSTRUCTIONS
WHAT IN THE BOX
Specifications
Battery Charger Input:| 100-240V, 50/60Hz. 0.6A
Maximum
---|---
Charge Temperature:| Maximum 104˚F (40˚C) Minimum 40˚F (5˚C)
Water Temperature:| Maximum 104˚F (40˚C) Minimum 40˚F (5˚C)
Operation Depth:| Maximum 5.5 ft. (1.6 m)
Minimum 10 in. (25 cm)
WARNING
- Only use the battery charger supplied with the cleaner.
- Product is not intended for use in swimming pools.
Important Tips
- Use only the battery charger supplied with the cleaner.
- Empty and clean the filter canister after every use.
- Charge Spabot indoors and allow cleaner to fully charge before each cycle.
Turning Spabot On and Off
- ON: Slide the On / Off switch towards the symbol to turn Spabot ON. The wheels and brushes will move forward and back once. The Battery LED will be solid green and the Info LED will flash green. Spabot is now ready to be placed in the spa. Spabot will automatically turn off if not placed in the water.
- OFF: Slide the On / Off switch towards the symbol to turn Spabot OFF. The Battery LED and the Info LED will turn off. Spabot will automatically turn off after the cleaning cycle is complete.
Anatomy
Charging
WARNING Only use the battery charger supplied with the cleaner. Do not use an extension cord. Follow all charging instructions and do not charge Spabot outside of the temperature range specified in the instructions. Charging improperly or at temperatures outside of the specified range may damage the battery and increase the risk of fire.
The cleaner is shipped with a partial charge for safety. Fully charge the cleaner (4 hrs) before using it for the first time.
-
When charging, place the cleaner on a flat surface in a clean, dry, well-ventilated area indoors, preferably inside your home, a garage, or shed, with an ambient temperature between 40ºF (5ºC) and 104ºF (40ºC).
NOTE: When charging, the cleaner must not be exposed to direct sunlight, heat ignition sources, pool chemicals or water. Do not position in direct contact with soil or humid environments. -
Connect the battery charger to the back of the cleaner.
NOTE: The charger plug is keyed and only fits into the charging port one way. -
Plug the power cord into a GFCI- protected power outlet. The Battery LED will be flashing Orange to indicate power is on and the cleaner is charging.
-
When charging is complete, the Battery LED is solid Green, indicating a full charge. NOTE : Unplug the charger from the back of the cleaner when fully charged, to extend battery life.
Cleaning
WARNING: To avoid risk of potentially serious injury, do not use the spa when the cleaner is submerged or operating. Turn off spa pump and jets while using cleaner. Not intended for use in swimming pools.
Cleaning Pattern
Spabot autonomously navigates around the floor, seats, and walls of your spa to clean in only 60 minutes.
Start Cleaning
- Slide down and release the On/Off power switch. Wheels and brushes quickly move forward and back one time to confirm power is on.
- Submerge the cleaner in the spa.(The cleaner will not begin until it senses water.)
- Hold under water until the bubbles are gone.
- When the bubbles stop, release the cleaner. The cleaner will sense it is in water and begin to move.
Remove from Spa
- When the cleaning cycle ends, the cleaner will float at the surface and the LEDs will be OFF.
- When in reach, grab the cleaner and remove from the spa.
- Set the cleaner on its back to accelerate water drainage.
Empty the Filter Canister
Empty the filter canister after every cleaning cycle.
- Press the lid release latch and remove the lid.
- Press the filter cover release to remove the filter canister.
- Empty debris and rinse the filter canister with fresh water. Reattach canister to the lid. NOTE : Fine debris can impact the canister filtration and cleaner performance over time. Periodically, clean thoroughly with soapy water and a soft bristle brush.
- To reattach the lid, insert the tab on the lid into the slot on the body (a), then rotate the lid down to close the latch (b).
- Allow the cleaner to dry fully before reconnecting it to the charger.
Storing & Maintaining
Everyday Storage
- Store the cleaner in a protected and dry place with an ambient temperature between 40°F (5°C) and 104°F (40°C), out of reach of children and pets.
- Never store or dry the cleaner in direct sunlight.
- Do not expose cleaner to fire, excessive temperatures, ignition sources, or pool/spa chemicals.
- Do NOT leave cleaner in water when not in use.
Routine Maintenance
- Routine maintenance is essential for keeping the cleaner in good working order and can prolong the life of your spa cleaner.
Routine maintenance:
- Clean brushes and all exposed moving parts.
- Periodically, clean the filter canister thoroughly with soapy water and a soft bristle brush.
- Check for worn or damaged parts, such as lid, filter canister, brushes. Check battery charge level and recharge the cleaner at least every 6 months.
- Disconnect plug from the power supply when not in use.
Long-term & Winter
- Remove the cleaner from the spa and drain all water to avoid freezing water damage (freeze damage is not covered under the warranty).
- You must recharge the battery at least once every 6 months when it is not in use.
- Unplug the battery charger from the cleaner.
Recycling & Disposal
The battery is not a serviceable or replaceable component. Do not attempt to
service the battery.
Battery and cleaner must be disposed of in accordance with local requirements.
Always dispose of batteries in a sustainable way in approved collection bins
or at authorized collection centers in accordance with local law. Contact your
local authority for more information.
WARNINGS for additional battery information.
Basic Troubleshooting
Problem | Solution |
---|---|
Cleaner does not turn on | • Low battery. Charge until battery LED is |
solid green.
• Slide the On/ Off switch down towards the symbol to start the
cleaner.
• Overheated. Move cleaner to cooler area. Do not store above 104ºF (40ºC) or in direct sunlight.
Cleaner does not charge| • No power. Reset GFCI circuit breaker. Plug the charger into a different outlet.
• Dirty connection. Clear debris from charging port on cleaner.
Cleaner does not dive -or- does not move in water| • Trapped air. Hold cleaner under water, tilt and shake to release air bubbles.
• Filter full / dirty. Empty canister, wash with soapy water and a soft
brush.
• Make sure the pivoting float arm moves freely.
• Manually rotate wheels back and forth to release blockage.
Cleaner does not climb spa walls -or- does not reach all areas| • Filter full / dirty. Empty canister, wash with soapy water and a soft
brush.
• Turn off spa pump and jets while using cleaner.
• Water chemistry imbalance. Consult a spa service professional.
• Some spa designs may have areas inaccessible to the cleaner.
Lid detaches unexpectedly| • Reattach lid securely (see step in “Empty the Filter Canister”
section ).
• Latch stuck. See latch problem / solutions below.
Latch is difficult to open -or- does not stay closed| • Submerge cleaner in water, open and close latch a few times to rinse out debris.
• Completely dry out cleaner, open and close latch a few times, blow out debris.
Debris escaping from filter| • Remove canister, wash with soapy water and a soft brush.
• Make sure canister is seated and oriented properly.
Cleaner floats to the surface| • Normal operation. Cleaner stops and floats when the cleaning cycle is done.
• Normal operation. Cleaner floats periodically during navigation.
Cleaner does not float to the surface at end of cycle| • Canister
full with heavy debris. Empty filter canister.
Flashing red LED| • Blockage detected. Turn off cleaner and remove
lid. Clear debris from exposed moving parts.
NOTE: If a problem persists, please contact your local retailer to request a diagnostic review, or call 1.800.822.7933 for technical support.
CONTACT
Zodiac Pool Systems LLC
- ADDRESS: 2882 Whiptail Loop # 100 Carlsbad, CA 92010, USA
- WEB: PolarisPool.com
- TELL: 1.800.822.7933
Zodiac Pool Systems Canada, Inc.
- ADDRESS: 2-3365 Mainway Burlington, ON L7M 1A6, Canada
- WEB: PolarisPool.ca
- TELL: 1.800.822.7933
A Fluidra Brand
©2022 Zodiac Pool Systems LLC. All rights reserved. Polaris® and the Polaris
3-wheeled cleaner design are registered trademarks of Zodiac Pool Systems LLC.
All other trademarks referenced herein are the property of their respective
owners.
H0655300 REVD
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>