LEDJ374 200W COB CW Par User Manual
- June 12, 2024
- LeDj
Table of Contents
200W COB CW/WW Par
User Manual
Order code: LEDJ374
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
- Before your initial start-up, please make sure that there is no damage caused during transportation.
- Should there be any damage, consult your dealer and do not use the equipment.
- To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
- Please note that damages caused by user modifications to this equipment are not subject to warranty.
| CAUTION!
KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS
---|---
| CAUTION!
TAKE CARE USING THIS EQUIPMENT!
HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by
the non-observance of this manual or any unauthorised modification to the
equipment.
- Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
- Never remove warning or informative labels from the unit.
- Do not open the equipment and do not modify the unit.
- Do not connect this equipment to a dimmer pack.
- Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.
- Only use the equipment indoors.
- Do not expose to flammable sources, liquids or gases.
- Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
- Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.
- Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.
- If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.
- If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature.
- If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service.
- Only use fuses of same type and rating.
- Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
- This lighting fixture is for professional use only – it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.
- Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
- WARRANTY: One year from date of purchase.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this
manual, the product may suffer damage and the warranty becomes void. Incorrect
operation may lead to danger e.g: short-circuit, burns and electric shocks
etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or
property.
Please note: These fixtures are intended for stage lighting and
entertainment applications only, and are not intended for extended periods of
use, including but not limited to house-light, industrial or architectural
applications and should only be operated with short duty cycles.
Product overview & technical specifications
200W COB CW/WW Par
The LEDJ 200W COB CW/WW Par is a powerful lighting fixture with a COB LED for
multiple applications. It features a high CRI for accurate colour
representation, an 80° beam angle and includes three interchangeable beam
reduction lenses (25°, 40°, and 50°). The 4-button menu display allows easy
access to built-in colour temperature presets and DMX modes.
- 1 x 200W cool white (6600K) and warm white (2800K) COB LED (CW/WW)
- Beam angle: 80° native, 25°, 40° and 50° beam reduction lenses supplied
- 80° – 3,789 Lux @ 2m (full on)
- 25° – 24,351 Lux @ 2m (full on)
- 40° – 9,102 Lux @ 2m (full on)
- 50° – 7,183 Lux @ 2m (full on)
- Refresh rate: 900Hz, 1kHz, 1.2kHz, 1.5kHz, 2.5kHz, 4kHz, 5kHz, 10kHz, 15kHz or 20kHz selectable
- DMX channels: 2/4/5 or 7 selectable
- CRI: CW-90, WW-93
- Manual and master/slave modes plus colour temperature presets
- 0-100% dimming
- Variable strobe
- Bracket allows for multiple rigging or floor standing applications
- 4 push button menu with OLED display
- Power CON input/output
- 5-Pin XLR input/output
- 3-Pin XLR input/output
- Fan cooled
- Filter frame included
Specifications | 200W COB CW/WW Par |
---|---|
Power consumption | 205W |
Power supply | 100~240V, 50/60Hz |
Fuse | T3.15A 250V |
Dimensions | 300 x 260 x 280mm |
Weight | 4.3kg |
Order code | LEDJ374 |
01 – OLED display
02 – Function buttons
03 – Hanging bracket
04 – Adjustable knobs
05 – Power CON input
06 – 3-Pin DMX input| 07 – Fuse T3.15A 250V
08 – 5-Pin DMX input
09 – 5-Pin DMX output
10 – Safety eye
11 – 3-Pin DMX output
12 – Power CON output
---|---
In the box:
1 x fixture, 1 x filter frame,
1 x 25° beam reduction lens,
1 x 40° beam reduction lens,
1 x 50° beam reduction lens,
& 1 x power cable
Operating instructions
Main Menu | Sub Menu | Options/Values (Default Settings in BOLD) |
---|---|---|
DMX Address | 001-512 | |
Channel | 2 Channel |
4 Channel
5 Channel
7 Channel
Dimmer Curve| Linear
Square Law
Inv SQ Law
S Curve
LED Refresh| 900Hz. 1000Hz. 1200Hz. 1500Hz. 2500Hz. 4000Hz. 5000Hz. 10kHz.
15kHz. 20kHz
DMX Fail| Blackout
Last
Program
Master/Slave| Slave| Master
Slave
Manual Dimming| CW| 000-255
WW| 000-255
Flash| 0-15
Static CCT| Colour| 2800K. 3200K. 3600K. 4000K. 4400K. 5600K. 6000K. 6600K
Flash| 0-15
Display| Display Backlight Auto| On
Off
Display Inverse| No
Yes
Display Contrast| 1-10 (9)
Fixture Information| Fixture use time| 0
Fixture version| CPU-A V 1.0 B 1.0
Reset Factory| Default No| No
Yes
2 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Cool White dimmer (0-100%) |
2 | 000-255 | Warm White dimmer (0-100%) |
4 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Cool White dimmer (0-100%) |
2 | 000-255 | Warm White dimmer (0-100%) |
3 | 000-020 | Linear |
021-040 | Square Law | |
041-060 | Inverse Square Law | |
061-080 | S-Curve | |
081-255 | Default (set via menu) | |
4 | 000-015 | Default (set via menu) |
016-040 | 900Hz | |
041-065 | 1000Hz | |
066-090 | 1200Hz | |
091-115 | 1500Hz | |
116-140 | 2500Hz | |
141-165 | 4000Hz | |
166-190 | 5000Hz | |
191-215 | 10KHz | |
216-240 | 15KHz | |
241-255 | 20KHz |
5 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Cool White dimmer (0-100%) |
2 | 000-255 | Warm White dimmer (0-100%) |
3 | 000-255 | Master dimmer (0-100%) |
4 | 000-020 | Linear |
021-040 | Square Law | |
041-060 | Inverse Square Law | |
061-080 | S-Curve | |
081-255 | Default (set via menu) | |
5 | 000-015 | Default (set via menu) |
016-040 | 900Hz | |
041-065 | 1000Hz | |
066-090 | 1200Hz | |
091-115 | 1500Hz | |
116-140 | 2500Hz | |
141-165 | 4000Hz | |
166-190 | 5000Hz | |
191-215 | 10KHz | |
216-240 | 15KHz | |
241-255 | 20KHz |
DMX mode (cont.):
7 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Cool White dimmer (0-100%) |
2 | 000-255 | Warm White dimmer (0-100%) |
3 | 000 | No Function |
001-255 | Variable White (3200K – 6400K) | |
4 | 000-031 | No Function |
032-063 | Open | |
064-095 | Strobe (slow-fast) | |
096-127 | Open | |
128-159 | Strobe Burst (slow-fast) | |
160-191 | Open | |
192-223 | Random Strobe (slow-fast) | |
224-255 | Open | |
5 | 000-255 | Master dimmer (0-100%) |
6 | 000-020 | Linear |
021-040 | Square Law | |
041-060 | Inverse Square Law | |
061-080 | S-Curve | |
081-255 | Default (set via menu) | |
7 | 000-015 | Default (set via menu) |
016-040 | 900Hz | |
041-065 | 1000Hz | |
066-090 | 1200Hz | |
091-115 | 1500Hz | |
116-140 | 2500Hz | |
141-165 | 4000Hz | |
166-190 | 5000Hz | |
191-215 | 10KHz | |
216-240 | 15KHz | |
241-255 | 20KHz |
DMX setup
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each fixture
requires a “start address” from 1- 512. A fixture requiring one or more
channels for control begins to read the data on the channel indicated by the
start address. For example, a fixture that occupies or uses 7 channels of DMX
and was addressed to start on DMX channel 100, would read data from channels:
100, 101, 102, 103, 104, 105 and 106. Choose a start address so that the
channels used do not overlap. E.g. the next unit in the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of
communication between intelligent fixtures and controllers. A DMX controller
sends DMX data instructions form the controller to the fixture.
DMX data is sent as serial data that travels from fixture to fixture via the
DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most
controllers only have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to
be linked together and operate from a single controller, as long as all
fixtures and the controller are DMX compliant.
To ensure proper DMX data transmission, when using several DMX fixtures try to
use the shortest cable path possible. The order in which fixtures are
connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be
placed anywhere in a DMX line, at the beginning, at the end, or anywhere in
the middle. When a fixture is assigned a DMX address of 1, the DMX controller
knows to send DATA assigned to address 1 to that unit, no matter where it is
located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This fixture can be controlled via DMX-512 protocol. The DMX address is set on
the back of the unit.
Your unit requires either a standard 3-pin or 5-pin XLR connector for data
input/output, see images below.
Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:
3-Pin: | CABL185 – 2m | CABL187 – 5m | CABL188 – 10m |
---|---|---|---|
5-Pin: | CABL10 – 2m | CABL11 – 5m | CABL12 – 10m |
Also remember that DMX cable must be daisy chained and cannot be split.
Notice:
Be sure to follow the diagrams below when making your own cables.
Do not connect the cables shield conductor to the ground lug or allow the
shield conductor to come in contact with the XLRs outer casing. Grounding the
shield could cause a short circuit and erratic behaviour.
Pin Configuration
3-Pin| 5-Pin
Pin 1 – Ground
Pin 2 – Negative
Pin 3 – Positive
–| Pin 4 – N/C
–| Pin 5 – N/C
Line termination:
When longer runs of cable are used, you may need to use a terminator on the
last unit to avoid erratic behaviour.
Using a cable terminator will decrease the possibilities of erratic behaviour.
(3-pin – Order ref: CABL90, 5-pin – Order ref: CABL89)
| Termination reduces signal transmission problems and interference. It is
always
advisable to connect a DMX terminal, (resistance 120 Ohm 1/4W) between pin 2
(DMX-) and pin 3 (DMX+) of the last fixture.|
---|---|---
5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of
3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When
inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor
must be used. The diagram below details the correct cable conversion.
Multiple fixture power linking
Power linking:
This fixture provides power linking via the power output on the rear allowing
multiple units to be connected together. The maximum number of fixtures that
can be connected is 12 fixtures @ 240V or 6 fixtures @ 120V (including the
first fixture). After the maximum number of fixtures are connected a new power
run will need to be started.
Please note: Caution should be used when power linking other fixtures to the
200W COB CW/WW Par as the power consumption of other fixtures will vary.
Fixtures fitted with lamps often require 2/3 times more current on startup,
these may require their own power source.
WEEE notice
Correct Disposal of this Product (Waste Electrical & Electronic
Equipment)
(Applicable in the European Union and other European countries with
separate collection systems)
This marking shown on the product or its literature, indicates that it should
not be disposed with other household wastes at the end of its working life. To
prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they
can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and
conditions of the purchase contract. This product should not be mixed with
other commercial wastes for disposal.
www.prolight.co.uk
200W COB CW/WW Par User Manual