LEDJ377 200W COB RGBAL Par User Manual
- June 13, 2024
- LeDj
Table of Contents
200W COB RGBAL Par
User Manual
Order code: LEDJ377
LEDJ377 200W COB RGBAL Par
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
- Before your initial start-up, please make sure that there is no damage caused during transportation.
- Should there be any damage, consult your dealer and do not use the equipment.
- To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
- Please note that damages caused by user modifications to this equipment are not subject to warranty.
CAUTION! KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS
CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC
SHOCK!!
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by
the non-observance of this manual or any unauthorised modification to the
equipment.
- Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
- Never remove warning or informative labels from the unit.
- Do not open the equipment and do not modify the unit.
- Do not connect this equipment to a dimmer pack.
- Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.
- Only use the equipment indoors.
- Do not expose to flammable sources, liquids or gases.
- Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
- Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.
- Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.
- If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.
- If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature.
- If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service.
- Only use fuses of same type and rating.
- Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
- This lighting fixture is for professional use only – it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.
- Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
- WARRANTY: One year from date of purchase.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this
manual, the product may suffer damage and the warranty becomes void. Incorrect
operation may lead to danger e.g: short-circuit, burns and electric shocks
etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or
property.
Please note: These fixtures are intended for stage lighting and entertainment
applications only, and are not intended for extended periods of use, including
but not limited to house-light, industrial or architectural applications and
should only be operated with short duty cycles.
Product overview & technical specifications
200W COB RGBAL Par
The LEDJ 200W COB RGBAL Par is a powerful lighting fixture with a COB LED
for high-output wash and seamless colour mixing. It features a high CRI for
accurate colour representation, an 80° beam angle and includes three
interchangeable beam reduction
lenses (25°, 40°, and 50°). The 4-button OLED display allows easy access to
built-in colour macros, colour temperature presetsauto, sound active, and DMX
modes.
- 1 x 200W quad-colour COB LED (RGBAL)
- Beam angle: 80° native, 25°, 40° and 50° beam reduction lenses supplied
- 80° – 2,307 Lux @ 2m (full on), 25° – 11,716 Lux @ 2m (full on),40° – 5,227 Lux @ 2m (full on), 50° – 4,110 Lux @ 2m (full on)
- Refresh rate: 1kHz 10KHz, 15KHz, 20KHz selectable
- DMX channels: 2/5/7/8/9 or 13 selectable
- CRI: 93
- Auto, sound active and master/slave modes plus built-in programs
- 0-100% dimming
- Variable strobe
- Supplied with hanging bracket
- 4 push button menu with OLED display
- Power CON input/output
- 5-Pin XLR input/output
- 3-Pin XLR input/output
- Fan cooled
Specifications | 200W COB RGBAL Par |
---|---|
Power consumption | 205W |
Power supply | 100~240V, 50/60Hz |
Fuse | T3.15A 250V |
Dimensions | 300 x 260 x 280mm |
Weight | 4.3kg |
Order code | LEDJ377 |
25′-Lux FULL ON
R
G
B
A
L| 46864
11800
13300
4380
11000
17172| 11716
2950
3325
1095
2750
4293| 5207
1311
1477
487
1222
1908| 2929
737
831
274
687
1073| 1874
472
532
175
440
687
---|---|---|---|---|---
40″-Lux FULL ON
R
G
B
A
L| 20908
5312
5668
1940
4296
8064| 5227
1328
1417
485
1074
2016| 2323
590
630
215
477
896| 1307
332
354
121
268
504| 836
212
227
78
172
322
50°-Lux FULL ON
R
G
B
A
L| 16440
3924
4156
1424
3160
6312| 4110
981
1039
356
790
1578| 1827
436
462
158
351
701| 1027
245
260
89
197
394| 658
157
166
57
126
252
80°-Lux FULL ON R
G
B
A
L| 9228
2420
2404
824
1924
3520| 2307
605
601
206
481
880| 1025
269
267
91
214
391| 577
151
150
51
120
220| 369
97
96
33
77
141
Technical specifications
- – OLED display
- – Function buttons
- – Hanging bracket
- – Adjustable knobs
- Power CON input
- – 3-Pin DMX input
- Fuse T3.15A 250V
- – 5-Pin DMX input
- – 5-Pin DMX output
- – Safety eye
- – 3-Pin DMX output
- – Power CON output
In the box: 1 x fixture, 1 x 25° beam reduction lens, 1 x 40° beam reduction lens, 1 x 50° beam reduction lens, & 1 x power cable
Operating instructions
Main Menu | Sub Menu | Options/Values (Default Settings in BOLD) |
---|---|---|
DMX Address | DMX Address | 001 -512 |
Channel | 2 Channel |
5 Channel
7 Channel
8 Channel
9 Channel
13 Channel
Dimmer Curve| Linear
Square Law
Inv SQ Law
S Curve
LED Refresh| 900Hz, 1000Hz, 1200Hz , 1500Hz, 2500Hz, 4000Hz, 5000Hz,
10kHz, 15kHz, 20kHz
DMX Fail| Blackout
Last
Program
Master/Slave| Slave| Master
Slave
Manual Dimming| Red| 000 -255
Green| 000 -255
Blue| 000 -255
Amber| 000 -255
Lime| 000 -255
Flash| 0 -15
Sound Active| Sound Inex| 1 -16
Sound Sensitivity| 1-8 (6)
Auto Fade| Auto Fade| 1 -16
Auto Change| 1-16 (4)
Speed| 1 -16
Static Colour| Colour| 00-64 (1)
CCT| 00, 1800K, 1850K, 1900K, 1950K, 2000K, 2050K, 2100K, 2150K, 2200K, 2250K,
2300K ,2350K, 2400K, 2450K, 2500K, 2550K, 2600K, 2650K, 2700K, 2750K, 2800K,
2900K, 3000K, 3100K, 3200K, 4400K, 5600K, 7200K, 10000K
Flash| 00-15
Display| Display Backlight Auto| On
Off
Display Inverse| No
Yes
Display Contrast| 1- 10
Fixture information| Fixture use time| 0
Fixture version| CPU-A V 1.0 B 1.0
Reset Factor| Default No| No
Yes
2 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-009 | No function |
010-017 | 1800K | |
018-025 | 1850K | |
026-033 | 1900K | |
034-041 | 1950K | |
042-049 | 2000K | |
050-057 | 2050K | |
058-065 | 2100K | |
066-073 | 2150K | |
074-081 | 2200K | |
082-089 | 2250K | |
090-097 | 2300K | |
098-105 | 2350K | |
106-113 | 2400K | |
114-121 | 2450K | |
122-129 | 2500K | |
130-137 | 2550K | |
138-145 | 2600K | |
146-153 | 2650K | |
154-161 | 2700K | |
162-169 | 2750K | |
170-177 | 2800K | |
178-185 | 2900K | |
186-193 | 3000K | |
194-201 | 3100K | |
202-209 | 3200K | |
210-217 | 4400K | |
218-225 | 5600K | |
226-233 | 7200K | |
234-255 | 10000K | |
2 | 000-255 | Master dimmer (0-100%) |
3 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Colour macros (see page 10) |
2 | 000-031 | LED off |
032-063 | LED on | |
064-095 | Strobe (slow-fast) | |
096-127 | LED on | |
128-159 | Strobe pulse (slow-fast) | |
160-191 | LED on | |
192-223 | Strobe random (slow-fast) | |
224-255 | LED on | |
3 | 000-255 | Master dimmer (0-100%) |
5 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red dimmer (0-100%) |
2 | 000-255 | Green dimmer (0-100%) |
3 | 000-255 | Blue dimmer (0-100%) |
4 | 000-255 | Amber dimmer (0-100%) |
5 | 000-255 | Lime dimmer (0-100%) |
7 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red dimmer (0-100%) |
2 | 000-255 | Green dimmer (0-100%) |
3 | 000-255 | Blue dimmer (0-100%) |
4 | 000-255 | Amber dimmer (0-100%) |
5 | 000-255 | Lime dimmer (0-100%) |
6 | 000-031 | LED off |
032-063 | LED on | |
064-095 | Strobe (slow-fast) | |
096-127 | LED on | |
128-159 | Strobe pulse (slow-fast) | |
160-191 | LED on | |
192-223 | Strobe random (slow-fast) | |
224-255 | LED on | |
7 | 000-255 | Master dimmer (0-100%) |
9 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red dimmer (0-100%) |
2 | 000-255 | Green dimmer (0-100%) |
3 | 000-255 | Blue dimmer (0-100%) |
4 | 000-255 | Amber dimmer (0-100%) |
5 | 000-255 | Lime dimmer (0-100%) |
6 | 000-031 | LED off |
032-063 | LED on | |
064-095 | Strobe (slow-fast) | |
096-127 | LED on | |
128-159 | Strobe pulse (slow-fast) | |
160-191 | LED on | |
192-223 | Strobe random (slow-fast) | |
224-255 | LED on | |
7 | 000-255 | Master dimmer (0-100%) |
8 | 000-020 | Linear |
021-040 | Square Law | |
041-060 | Inverse Square Law | |
061-080 | S-Curve | |
081-255 | Default (set via menu) | |
9 | 000-015 | Default (set via menu) |
016-040 | 900Hz | |
041-065 | 1000Hz | |
066-090 | 1200Hz | |
091-115 | 1500Hz | |
116-140 | 2500Hz | |
141-165 | 4000Hz | |
166-190 | 5000Hz | |
190-215 | 10KHz | |
216-240 | 15KHz | |
241-255 | 20KHz |
13 channel mode:
Channel | Value | Function |
---|---|---|
1 | 000-255 | Red dimmer (0-100%) |
2 | 000-255 | Green dimmer (0-100%) |
3 | 000-255 | Blue dimmer (0-100%) |
4 | 000-255 | Amber dimmer (0-100%) |
5 | 000-255 | Lime dimmer (0-100%) |
6 | 000-031 | LED off |
032-063 | LED on | |
064-095 | Strobe (slow-fast) | |
096-127 | LED on | |
128-159 | Strobe pulse (slow-fast) | |
160-191 | LED on | |
192-223 | Strobe random (slow-fast) | |
224-255 | LED on | |
7 | 000-255 | Master dimmer (0-100%) |
8 | 000-009 | No function |
010-017 | 1800K | |
018-025 | 1850K | |
026-033 | 1900K | |
034-041 | 1950K | |
042-049 | 2000K | |
050-057 | 2050K | |
058-065 | 2100K | |
066-073 | 2150K | |
074-081 | 2200K | |
082-089 | 2250K | |
090-097 | 2300K | |
098-105 | 2350K | |
106-113 | 2400K | |
114-121 | 2450K | |
122-129 | 2500K | |
130-137 | 2550K | |
138-145 | 2600K | |
146-153 | 2650K | |
154-161 | 2700K | |
162-169 | 2750K | |
170-177 | 2800K | |
178-185 | 2900K | |
186-193 | 3000K | |
194-201 | 3100K | |
Channel | Value | Function |
--- | --- | --- |
8 (cont.) | 000-255 | 3200K |
000-255 | 4400K | |
000-255 | 5600K | |
000-255 | 7200K | |
000-255 | 10000K | |
9 | 000-051 | No function |
052-102 | Colour temperature presets (CH8 value 000-255) | |
103-153 | Colour change mode | |
154-204 | Colour fade mode | |
205-255 | Sound active mode | |
10 | 000-042 | Colour Change 1/Colour fade 1 |
043-084 | Colour Change 2/Colour fade 3 | |
085-127 | Colour Change 3/Colour fade 3 | |
128-170 | Colour Change 4/Colour fade 4 | |
171-213 | Colour Change 5/Colour fade 5 | |
213-255 | Colour Change 6/Colour fade 6 | |
213-255 | Sound Active | |
11 | 000-255 | No function (CH9 value 000-102) |
000-255 | Speed (slow-fast) (CH9 value 103-204) | |
000-255 | Sensitivity (low-high) (CH9 value 205-255) | |
12 | 000-020 | Linear |
021-040 | Square Law | |
041-060 | Inverse Square Law | |
061-080 | S-Curve | |
081-225 | Default (set via menu) | |
13 | 000-015 | Default (set via menu) |
016-040 | 900Hz | |
041-065 | 1000Hz | |
066-090 | 1200Hz | |
091-115 | 1500Hz | |
116-140 | 2500Hz | |
141-165 | 4000Hz | |
166-190 | 5000Hz | |
190-215 | 10KHz | |
216-240 | 15KHz | |
241-255 | 20KHz |
Colour Chart:
Menu| DMX Values| Colour Temperature| Red| Green|
Blue| Amber| Lime
---|---|---|---|---|---|---|---
Colour 1| 001-004| –| 000| 255| 255| 001| 116
Colour 2| 005-008| –| 127| 255| 212| 001| 124
Colour 3| 009-012| –| 151| 125| 003| 255| 043
Colour 4| 013-016| –| 000| 000| 255| 001| 000
Colour 5| 017-020| –| 138| 043| 226| 001| 177
Colour 6| 021-024| –| 223| 108| 007| 255| 077
Colour 7| 025-028| –| 165| 042| 042| 001| 200
Colour 8| 029-032| –| 095| 158| 160| 044| 071
Colour 9| 033-036| –| 171| 036| 000| 120| 255
Colour 10| 037-040| –| 127| 255| 000| 001| 255
Colour 11| 041-044| –| 210| 105| 030| 001| 022
Colour 12| 045-048| –| 255| 015| 018| 255| 174
Colour 13| 049-052| –| 100| 149| 237| 003| 000
Colour 14| 053-056| –| 255| 000| 010| 255| 144
Colour 15| 057-060| –| 220| 020| 060| 001| 000
Colour 16| 061-064| –| 000| 255| 255| 000| 012
Colour 17| 065-068| –| 006| 000| 139| 001| 003
Colour 18| 069-072| –| 000| 139| 139| 002| 005
Colour 19| 073-076| –| 000| 111| 000| 001| 024
Colour 20| 077-080| –| 255| 000| 002| 021| 003
Colour 21| 081-084| –| 188| 000| 003| 255| 044
Colour 22| 085-088| –| 255| 012| 000| 077| 062
Colour 23| 089-092| –| 255| 130| 25| 229| 030
Colour 24| 093-096| –| 140| 000| 139| 002| 135
Colour 25| 097-100| –| 255| 140| 000| 001| 000
Colour 26| 101-104| –| 153| 050| 204| 001| 005
Colour 27| 105-108| –| 143| 188| 143| 001| 035
Colour 28| 109-112| –| 072| 061| 139| 004| 002
Colour 29| 113-116| –| 000| 206| 209| 002| 002
Colour 30| 117-120| –| 255| 000| 004| 011| 008
Colour 31| 121-124| –| 148| 000| 211| 005| 002
Colour 32| 125-128| –| 255| 020| 147| 001| 000
Colour 33| 129-132| –| 000| 191| 255| 002| 003
Colour 34| 133-136| –| 160| 000| 26| 000| 004
Colour 35| 137-140| –| 034| 139| 034| 001| 001
Colour 36| 141-144| –| 255| 000| 255| 002| 000
Colour 37| 145-148| –| 255| 215| 000| 001| 001
Colour 38| 149-152| –| 005| 255| 190| 003| 011
Menu| DMX Values| Colour Temperature| Red| Green|
Blue| Amber| Lime
---|---|---|---|---|---|---|---
Colour 39| 153-156| –| 012| 255| 062| 095| 049
Colour 40| 157-160| –| 005| 209| 255| 015| 170
Colour 41| 161-164| –| 000| 005| 128| 005| 005
Colour 42| 165-168| –| 255| 105| 180| 002| 001
Colour 43| 169-172| –| 007| 255| 025| 070| 077
Colour 44| 173-176| –| 147| 164| 212| 000| 002
Colour 45| 177-180| –| 002| 255| 015| 003| 019
Colour 46| 181-184| –| 000| 038| 086| 000| 000
Colour 47| 185-188| –| 255| 000| 005| 121| 010
Colour 48| 189-192| –| 005| 148| 209| 005| 019
Colour 49| 193-196| –| 001| 255| 062| 093| 044
Colour 50| 197-200| 2300K| 150| 004| 004| 255| 255
Colour 51| 201-204| 2600K| 140| 015| 008| 255| 255
Colour 52| 205-208| 2800K| 130| 025| 010| 255| 255
Colour 53| 209-212| 3100K| 110| 030| 015| 255| 255
Colour 54| 213-216| 3400K| 100| 050| 020| 255| 255
Colour 55| 217-220| 7000K| 075| 110| 070| 255| 255
Colour 56| 221-224| 8000K| 075| 125| 085| 255| 255
Colour 57| 225-228| 3800K| 090| 060| 025| 255| 255
Colour 58| 229-232| 4100K| 080| 071| 030| 255| 255
Colour 59| 233-236| 4500K| 080| 085| 038| 255| 255
Colour 60| 237-240| 4900K| 080| 095| 046| 255| 255
Colour 61| 241-244| 5500K| 075| 110| 055| 255| 255
Colour 62| 245-248| 6000K| 075| 110| 070| 255| 255
Colour 63| 249-252| 9000K| 065| 045| 097| 255| 255
Colour 64| 253-255| 9900K| 055| 165| 117| 255| 255
Setting the DMX address:
The DMX mode enables the use of a universal DMX controller. Each fixture
requires a “start address” from 1- 512. A fixture requiring one or more
channels for control begins to read the data on the channel indicated by the
start address. For example, a fixture that occupies or uses 7 channels of DMX
and was addressed to start on DMX channel 100, would read data from channels:
100, 101, 102, 103, 104, 105 and 106. Choose a start address so that the
channels used do not overlap. E.g. the next unit in the chain starts at 107.
DMX 512:
DMX (Digital Multiplex) is a universal protocol used as a form of
communication between intelligent fixtures and controllers. A DMX controller
sends DMX data instructions form the controller to the fixture. DMX data is
sent as serial data that travels from fixture to fixture via the DATA “IN” and
DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only
have a data “out” terminal).
DMX linking:
DMX is a language allowing all makes and models of different manufactures to
be linked together and operate from a single controller, as long as all
fixtures and the controller are DMX compliant. To ensure proper DMX data
transmission, when using several DMX fixtures try to use the shortest cable
path possible. The order in which fixtures are connected in a DMX line does
not influence the DMX addressing. For example; a fixture assigned to a DMX
address of 1 may be placed anywhere in a DMX line, at the beginning, at the
end, or anywhere in the middle. When a fixture is assigned a DMX address of 1,
the DMX controller knows to send DATA assigned to address 1 to that unit, no
matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation):
This fixture can be controlled via DMX-512 protocol. The DMX address is set on
the back of the unit. Your unit requires either a standard 3-pin or 5-pin XLR
connector for data input/output, see images below.
Further DMX
cables can be purchased from all good sound and lighting suppliers or
Portlight Concepts dealers.
Please quote:
3-Pin: | CABL185 – 2m | CABL187 – 5m | CABL188 – 10m |
---|---|---|---|
5-Pin: | CABL10 – 2m | CABL11 – 5m | CABL12 – 10m |
Also remember that DMX cable must be daisy chained and cannot be split.
Notice:
Be sure to follow the diagrams below when making your own cables. Do not
connect the cables shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLRs outer casing. Grounding the shield
could cause a short circuit and erratic behavior.
Line
termination:
When longer runs of cable are used, you may need to use a terminator on the
last unit to avoid erratic behavior. Using a cable terminator will decrease
the possibilities of erratic behavior. (3-pin – Order ref: CABL90, 5-pin –
Order ref: CABL89)
Pin Configuration
3-Pin| | 5-Pin
–| Pin 1- Ground
–| Pin 2 – Negative
–| Pin 3 – Positive
–| | Pin 4 – N/C
–| | Pin 5 – N/C
Termination
reduces signal transmission problems and interference. It is always advisable
to connect a DMX terminal, (resistance 120 Ohm 1/4W) between pin 2 (DMX-) and
pin 3 (DMX+) of the last fixture. 5-pin XLR DMX connectors:
Some manufactures use 5-pin XLR connectors for data transmission in place of
3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When
inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor
must be used. The diagram below details the correct cable conversion.
Multiple fixture power linking
Power linking:
This fixture provides power linking via the power output on the rear allowing
multiple units to be connected together. The maximum number of fixtures that
can be connected is 12 fixtures @ 240V or 6 fixtures @ 120V (including the
first fixture). After the maximum number of fixtures are connected a new power
run will need to be started.
Please note: Caution should be used when power linking other fixtures to the
200W COB RGBAL Par as the power consumption of other fixtures will vary.
Fixtures fitted with lamps often require 2/3 times more current on startup,
these may require their own power source.
WEEE notice
**** Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate
collection systems)
This marking shown on the product or its literature, indicates that it should
not be disposed with other household wastes at the end of its working life. To
prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this
product, or their local government office, for details of where and how they
can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and
conditions of the purchase contract. This product should not be mixed with
other commercial wastes for disposal.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>