SUNDRAX DGD-1-DE2DALI DALIGate DIN User Manual
- June 4, 2024
- SUNDRAX
Table of Contents
- SUNDRAX DGD-1-DE2DALI DALIGate DIN
- Specifications
- General information
- Safe operation
- Advantages
- Installation
- Operation
- Web interface settings
- ArtNet settings
- DALI control
- Network settings
- Connection scheme
- Technical maintenance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SUNDRAX DGD-1-DE2DALI DALIGate DIN
Specifications
- Supported protocols ArtNet, sACN, DMX512, RDM, DALI
- Data refresh rate 44 Hz
- DMX ports 1 isolated
- DMX connectors Terminal blocks 15EDGVC
- Controllable output lines 2 or 4 DALI
- Ethernet port 10/100 Base-TX
- Power supply ~90-250 VAC, 50/60 Hz or 15V
- Mains Fuse 0.5 A
- Operating Temperature -40…+70°C
- IP Rating IP 20
- Dimensions, mm 142(D) x 105(H) x 75(W)
General information
DALIGate DIN is DIN rail-mounted converter that converts ArtNET/sACN/DMX signal into DALI protocol to include DALI lighting fixtures into a controllable lighting network. With DIN rail mounting hassle-free installation and ArtNET/sACN/DMX input, DALIGate DIN is ideal as an indoor solution for mixed lighting control purposes in theatres, small venues, architectural installations, industrial, warehouse, and agricultural lighting.
Safe operation
In the installation, operation, preventive maintenance, and repairs of the device, the requirements of the safety rules must be followed. To ensure the safe and reliable operation of the devices, please observe the following requirements:
- Use the device only for its intended purpose
- Do not use devices that show signs of a malfunctioning
- Avoid strong physical impacts on the device
- Protect devices and cables from contact with moisture or other corrosive liquids
- Prevent any improper disconnection of the Ethernet cable from the device being disconnected
- Whenever a fault is detected in the device, please contact the manufacturer.
Advantages
- 2 DALI interfaces
- No external power supply for DALI is needed
- Simple web interface
- Selectable ArtNET/sACN or DMX512 control
Installation
Before mounting and powering up, it is necessary to verify protective earthing and cable connections.
- Ensure the device has no damage due to transportation
- Mount devise on DIN rail
- Connect Ethernet cable
- Connect DMX line input (if necessary) and DALI lines outputs
- Connect the power cable
- After a few seconds, port status LEDs will indicate the state. Open the device’s web interface on the computer connected to the same network as the DALIGate device
- Open the Network Settings tab
- STATIC IP ADDRESS field will display the address of the device, SUBNET MASK field will display the network mask. If necessary, fill in the IP and Subnet fields for the required network settings (by default, the device has IP 2.0.0.100 and Subnet 255.0.0.0). Click “Save settings” so that the new settings take effect
Warning!
Before mounting and turning on the power, you need to make sure protective
ground cable connections and places of their connection
Operation
DALIGate devices start their normal operation in a few seconds after they have been powered up. The device always operates based on the last saved settings. Viewing DALIGate settings does not affect normal operation until any of the settings have been saved. When changes are saved, the device applies the new settings immediately, without having to power it down.
Actual control of DALI devices is performed based on DALI interface conversion mode. If BROADCAST mode is selected, the value of START ADDRESS in ArtNet/sACN or DMX universe controls all devices on the DALI line. If GROUP mode is selected, 16 values beginning from START ADDRESS control the groups 0-15. If INDIVIDUAL mode is selected, 64 values beginning from START ADDRESS control DALI devices 0-63. Individual addresses of DALI devices are assigned during the search procedure. After all devices are found, they may be individually checked by clicking the checkbox. Group number may be assigned to the DALI device, to enable group conversion mode.
Web interface settings
DALIGate DIN devices support configuring most of their parameters through the Web interface using the HTTP protocol (TCP port 80).
ArtNet settings
To access the settings page enter the IP address of the device to the browser. Main settings page of the DALIGate DIN device will be displayed.
- Device name edit device name
- Input data protocol editable device description
- Off switching input data source: ArtNet, sACN, DMX512
- Subnet *16 + Universe Art-Net subnet number (0-15), Art-Net universe number (0-15) or sACN universe number (1-65279)
- Start Address DMX start address for the channel
- Mode Conversion mode:
- BROADCAST, GROUP, INDIVIDUAL
- To save the changes in the main settings, click «Save settings».
- To restore default values of main settings, click «Set default».
- To reset to the current saved values of main settings, click «Reset».
DALI control
To edit the settings of one of the DALI interfaces, click on the link “DALI1 CONTROL” or “DALI2 CONTROL”.
- Current DALI Network – shows the devices found on the DALI line
- Short Address Individual address of DALI device (0-63)
- Device Type Code of type, returning by device
- Group Current group number (0-15)
- Check the Checkbox for switching devices individually on and off
- Search Search – searching connected devices
- Refresh: Refresh – refresh list of detected devices
- All devices ON All devices ON – switch on all devices
- All devices OFF All devices OFF – switch off all devices
Network settings
To edit the network settings of the device, click on the link “Network settings”.
- MAC address hardware address and secondary (permanent) IP address of the device
- Main IP set the main network address of the device
- Subnetwork mask set the mask of the IP subnet
- The Gateway IP address set the network address of the gateway (if the ability to operate via the Internet is required)
- Art-Net UDP port set the UDP port for ArtNet protocol
- Static IP address main network address of the device
- Subnet mask the mask of the IP subnet
- Default Gateway network address of the gateway (if the ability to operate via the Internet is required)
To save the changes in network settings, click «Save settings».
Connection scheme
Technical maintenance
Maintenance, search and troubleshooting should be performed by service personnel. The device should be free from dirt, dents, and connecting cables, and wires must be intact and securely fastened. Please send all your warranty- related questions to support@sundrax.com All Sundrax products are covered by a 36-month warranty.
Sundrax Electronics 6008, First Central 200 2 Lakeside Drive, Park Royal, London NW10 7FQ United Kingdom + 44 (0) 208 991 33 19 office@sundrax.com. www.sundrax.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>