Specifications
General information
ArtGate is the series of full-featured converters for converting network
protocols ArtNet and sACN to light fixtures control protocol DMX512. Through
their 1, 2, 4, 8, 12 or 16 DMX ports, LAN interface and Optical port (ArtJet
Pro and GigaJet Pro), the devices transmit and receive DMX512 data streams via
Ethernet LAN functioning in 10Base-T or 100Base-T mode (100Base-FX in ArtJet
Pro, 1000Base-FX in GigaJet Pro).
Compatibility with ArtNet and sACN protocols enables the use of ArtGate
devices in a network
of heterogeneous devices from other manufacturers.
As well as the standard broadcast data transfer ArtNet, ArtGate devices also support point-to-point data transfer in the local network or via the Internet. Address settings of the device (name, SubNet, Universe) and network settings (IP address, subnet mask, UDP-port), standard software tools for ArtNet networks, such as DMX Workshop, as well as using the web based interface.
Web-interface allows changing advanced settings of ArtGate devices not covered
by the ArtNet standard, such as:
DMX signal direction and merge mode for each port physical characteristics
(timing) of DMX512 signal data stream transmission and reception modes in
ArtNet network
In addition, specialized utility software allows advanced users to assign
custom MAC address to the Ethernet interface of the device and restore default
settings of the device. ArtGate series is powered by AC ~90-250 V, 50/60 Hz,
or from Ethernet using the Power-over-Ethernet technology
(depends on modification).
Safe operation
In installation, operation, preventive maintenance and repairs of the device, the requirements of the safety rules must be followed.
- To ensure safe and reliable operation of the devices, please observe the following requirements:
- Use the device only for its intended purpose;
- Do not use devices that shows signs of malfunctioning;
- Avoid strong physical impacts on the device;
- Protect devices and cables from contact with corrosive liquids.
- Whenever a fault is detected in the device, please contact the manufacturer.
Merging
- HTP: highest takes precedence
- LTP: latest takes precedence
- AUTO: last modified takes precedence – intelligent merging mode
- PRIORITY: for sACN streams with priority tag
- BACKUP: primary/secondary universe backup
- TRIGGER and X-FADE: dedicated channel / dedicated universe controllable merging
Merging and other output ports procedures for different merge modes are shown in Pic2, Pic3, Pic4, Pic5.
Input processing
When configured as input, DMX port of ArtGate can convert DMX512 signal to
ArtNet, sACN or other type of universe. Universe type and protocol for input
ports is always taken from primary universe settings. Input port can respond
to RDM requests. Each port of one device has it’s own RDM UID.
Standalone merger
ArtGate devices may be used as standalone (without permanent Ethernet
connection) mergers. When 2 or more input ports are configured with the same
universe protocol/number, DMX streams from them can be merged and outputted to
another output port which must have the same protocol/number too to provide
such feature. This configuration may work even if device is not connected to
Ethernet.
Trigger inputs
Some ArtGate models have trigger feature. When trigger is activated, static
scene stored in non-volatile memory is recalled and set for all DMX ports.
Trigger is activated via “dry contact” inputs, which can be configured for
working with normally opened and normally closed sensors (smoke sensors,
buttons, etc). Each Trigger input can be also configured as alarm input. When
alarm is activated, device returns
to normal work only after power cycle or manual reset, not just input
deactivation.
By default, static scenes for all triggers are “all channels to 100%”. User
can set up the custom scene on all used DMX ports and then capture and save
the scene for necessary trigger.
Connection types
Ethernet connection
Device is connected to the network via RJ-45. All ArtGate devices have two LEDs to indicate the status of the network connection.
If there is no Ethernet connection, both LEDs are off, if network is connected, one LED is constantly on, the other one flashes when data are transmitted and received over the network. Each device has unique IP and MAC addresses. Device’s IP address, subnet mask, and other network parameters can be changed, but even in this case, the device is still available on the original IP address (2.x.x.x) for ping and http requests. Thus, even in case of loss of the new IP address, the device can be access on the network using the original IP address through the web-interface.
Fiber optics connections
ArtJet devices are equipped with 100 Mbit fiber optics port
(duplex SC connectors). Fiber optics port works as another network interface,
with functionality similar to Ethernet port. When connected both to fiber
optics and ethernet, device acts as a network
switch/media converter. DMX connections
XLR 5-pin connectors are used to connect external master and slave devices to
DMX ports. If necessary, the device can be equipped with XLR three-pin
connectors. Each port on the 2 and 4-port devices has 2 connectors — one M
connector and one F connector, which allow the port to pass-through the DMX
bus. On 8 and 16-port devices and ArtGate Compact, each port has single
connector of type F.
Each port is equipped with internal 120 ohms terminator which can be enabled
via web interface.
Web interface settings
ArtGate devices support configuring most of their parameters through the Web interface using HTTP protocol (TCP port 80).
Main settings
To access the settings page enter the IP address of the device to the browser. Main settings page of the ArtGate device will be displayed.
- Indication – switching LED indication modes:
- Normal Indication depending on the current port status
- Blink Search mode
- Off LEDs are off
Device name
Editable device name (up to 17 characters)
Device description
Editable device description (up to 63 characters)
Device status
Current state of the device
ArtNet 4 Net address
Network number (0-127, only for ArtNet 4)
To save the changes in main settings, click «Save settings».
To restore default values of main settings, click «Set default».
To reset to the current saved values of main settings, click «Reset».
Advanced settings
To edit the advanced settings of the device, click on the link “Advanced”.
Pic.10
Advanced settings
RDM devices – RDM devices list, connected to DMX ports:
RDM devices – RDM devices list, connected to DMX ports:
Start discovery Searching connected devices
Refresh report Refresh search/list state detected devices
DMX signal timing – sets the parameters of the output DMX signal for all ports:
-
Break
from 4 to 1000 µs -
MaB
from 4 to 1000 µs -
Data slots
1 to 512 -
Pause
from 0 to 10000 µs
DMX line terminator – enables (selected) or disables (cleared) termination resistor between D+ and D- wires of DMX line on each port.
Options – enable/disable device features
To save the changes in advanced settings, click «Save settings».
To restore default values of advanced settings, click «Set default».
To reset to the current saved values of advanced settings, click «Reset».
Network settings
To edit the network settings of the device, click on the link “Network”.
-
MAC address
Hardware address and secondary (permanent) IP-address of the device -
Main IP
Set the main network address of the device -
Subnetwork mask
Set the mask of the IP-subnet -
Gateway IP address
Set the network address of the gateway
(if ability to operate via the Internet is required) -
Art-Net UDP port sACN UDP port
Set the UDP-port for ArtNet protocol
Set the UDP-port for sACN protocol -
Access login/password
Login and password for access to web-interface of device.
If password is empty, authentification is not performed
To save the changes in network settings, click «Save settings».
To restore default values of network settings, click «Set default».
To reset to the current saved values of network settings, click «Reset».
Profiles
For profile operations, click on the link «Profiles».
- Download current profile Download the current settings as a file
- Profile for uploading Select the file of previously saved profile
- Upload profile To upload the selected profile in the device
Firmware update
To update firmware of the device, click on the link «Firmware».
After software update downloading, need to accept updating by clicking button «Reboot».
Technical maintenance
Maintenance, search and troubleshooting should be performed by service
personnel. The device should be free from dirt, dents, connecting cables and
wires must be intact and securely fastened.
Notes
Please send all your warranty-related questions to support@sundrax.com All Sundrax products are covered by a 36 months warranty.
Sundrax Electronics
6008, First Central 200
2 Lakeside Drive, Park Royal, London NW10 7FQ United Kingdom
+ 44 (0) 208 991 33 19
office@sundrax.com
www.sundrax.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>