Product Information

The Wall Mount Enclosure is a heavy-duty product designed for securely mounting and protecting equipment. It is suitable for indoor use and is equipped with various components and accessories to ensure proper installation and functionality. The enclosure features a front door, side panels, vertical mounting rails, and cable access points. It also includes a CyberPower badge for branding purposes.

Part Identification
The enclosure consists of several identifiable parts, including the front door, side panels, vertical mounting rails, and cable access points. These components are essential for assembling and setting up the enclosure.

Hardware and Accessories
The enclosure comes with the necessary hardware and accessories to facilitate installation. Please ensure all included items are present before proceeding with the setup.

Product Usage Instructions

Initial Enclosure Setup

  1. Lock Front Door: Securely lock the front door of the enclosure to prevent unauthorized access.
  2. Remove and Reverse Front Door: If necessary, remove the front door and reverse its orientation to suit your specific requirements.
  3. Relocate CyberPower Badge: Adjust the position of the CyberPower badge on the enclosure for branding purposes.
  4. Open Side Panels: Access the interior of the enclosure by opening the side panels. This allows for equipment installation and maintenance.
  5. Adjust Vertical Mounting Rails: Customize the position of the vertical mounting rails to accommodate different equipment sizes and configurations.

Mounting Depth
Consider the required mounting depth when installing equipment in the enclosure. Ensure that the equipment fits properly and does not exceed the recommended depth to avoid any issues during installation or operation.

Mounting Holes
Use the provided mounting holes to securely attach the enclosure to a wall or other suitable surfaces. Ensure the chosen mounting location is capable of supporting the total load, including the weight of the enclosure and any installed equipment.

Cable Access
Utilize the designated cable access points to route and manage cables within the enclosure. This helps maintain a clean and organized setup, reducing the risk of cable damage or interference.

Grounding
Properly ground the enclosure to ensure electrical safety. Follow recommended grounding procedures provided by a qualified professional or in accordance with local regulations.

Enclosure Installation
To install the enclosure on a wall:

  1. Choose a suitable location on the wall for installation.
  2. Securely mount the enclosure using the provided hardware and following the recommended installation instructions.

Equipment Installation
If mounting equipment using square holes:

  1. Ensure the equipment is compatible with square hole mounting.
  2. Follow the manufacturer’s instructions for securely attaching the equipment to the vertical mounting rails.

Always refer to the complete user manual for detailed instructions and safety precautions. Failure to follow these instructions may result in injury, damage to the unit, or voiding of the warranty.

Safety Instructions

Please read these instructions carefully before use.

  • The enclosure is a heavy object. The use of adequate mechanical means to move the enclosure to the desired location is highly recommended to minimize the risk of injury or unit damage. For safety reasons, it is highly recommended to handle this unit between two or more people. Use caution when unpacking, moving, and installing the enclosure. Failure to follow may cause serious injury or unit damage.
  • Handle the unit with care. Take precautions to avoid damaging the enclosure when unpacking, moving, repacking, or installing. Damage to the unit as a result of negligence is not covered under warranty.
  • Inspect the product and included accessories carefully before use. Do not use an enclosure with visible damage.
  • Before installing the enclosure, ensure that the wall or the floor is even and capable of supporting the total load being installed in the enclosure, including the enclosure itself. Do not mount the enclosure to the wall with equipment installed in it.
  • Do not stack enclosures and do not put any objects on the top of the enclosure.
  • Keep the enclosure in an appropriately ventilated space, and do not block the surrounding of the enclosure to ensure proper ventilation.
  • Install the enclosure in an indoor area free of dust, extreme moisture, and temperature changes, away from flammable objects, conductive contaminants, and exposure to direct sunlight.
  • Keep packaging materials if the enclosure will be re-shipped. Do not ship the enclosure with any equipment installed. This can cause damage to the packaging material which can result in unit damage.
  • The unique heavy-duty steel tube frame supports 60 KG (132 lbs.) We have enhanced security and improved access with swing outside panels which can only be opened from the inside. The high-density perforated front door is equipped with a sturdy lock to prevent unauthorized access.

Part Identification

Enclosure Components

CyberPower-CR6U61003-Carbon-Wall-Mount-Enclosures-fig-
\(1\)

  • a. Side panel LH
  • b. Side panel RH
  • c. Frame LH
  • d. Frame RH
  • e. Removable, Reversible, and Lockable Front Door
  • f. Rear cover
  • g. Bottom cover
  • h. Top cover

Hardware and Accessories

CyberPower-CR6U61003-Carbon-Wall-Mount-Enclosures-fig-
\(2\)

Initial Enclosure Setup

Lock Front Door

  • The lock location is shown below.
  • Use the included keys to operate the lock.

NOTE:
The enclosure is shipped with the door locked. To access the keys in the accessories bag outside of the enclosure .CyberPower-CR6U61003-Carbon-Wall-
Mount-Enclosures-fig- \(3\)

Optional Door Reversal

  1. Pull on the spring-loaded door pin hinge as shown below to remove the door from the enclosure. Remove the door pin supporting washer from the bottom hinge and reinstall it on the opposite door pin hinge.
  2. Rotate the front door and reinstall it on the opposite side sliding the door pin hinges into the hinge holes on the enclosure as shown below.
  3. To relocate the CyberPower badge, pull the two parts apart as shown below. To re-install the badge measure the vertical and horizontal distance from the edge of the door as shown below and push both parts together.

NOTE: Please press hard to make sure the badge has been firmly installed

CyberPower-CR6U61003-Carbon-Wall-Mount-Enclosures-fig-
\(6\)

Open Side Panels
Press and turn left the retention screw simultaneously to release the side panel.

CyberPower-CR6U61003-Carbon-Wall-Mount-Enclosures-fig-
\(7\)

Adjusting Vertical Mounting Rails

Mounting Depth
The installed depth of the vertical mounting rails can be adjusted by moving them forward or backward on the horizontal mounting rails.

CyberPower-CR6U61003-Carbon-Wall-Mount-Enclosures-fig-
\(8\)

Mounting Holes
The vertical mounting rails have square holes for use with cage nuts as shown below.

CyberPower-CR6U61003-Carbon-Wall-Mount-Enclosures-fig-
\(9\)

Cable Access
Cables can be routed through the top or bottom cable openings of the enclosure. To access the cable opening, remove the two screws securing the cover as shown below.

Grounding

WARNING
An individual grounding connection per enclosure is strongly recommended. Failure to follow may result in serious injury or death.

To connect the enclosure to the facility’s ground, use the M4 screw in the enclosure. The grounding point is marked in the enclosure with the ground symbol shown below.

CyberPower-CR6U61003-Carbon-Wall-Mount-Enclosures-fig-
\(11\)

Enclosure Installation

WARNING

  • The enclosure is a heavy object. For safety reasons, it is highly recommended to handle this unit with two or more people.
  • Failure to follow these instructions may cause serious injury, or unit damage.
Mounting on Wall

WARNING
Before installing the enclosure make sure that the wall is capable of supporting the total load being mounted in the enclosure, including the enclosure itself. Make sure the enclosure is properly mounted to the wall before installing equipment in the enclosure. Do not mount the enclosure with equipment installed in it.

Use the included expansion bolts, or other appropriate mounting hardware, to mount the enclosure to the wall as shown below.

The horizontal distance between keyholes, center to center, is 15.9” (406mm). The vertical distance between keyholes varies by model heights. Measure the vertical distance of the unit being installed before mounting the enclosure.

DIMENSIONS

Model| “A”| “B”
6U| 317mm (12.48 inch)| 190mm (7.48 inch)
9U| 450.35mm

(17.73 inch)

| 323.35mm

(12.73 inch)

12U| 583.7mm

(22.98 inch)

| 456.7mm

(17.98 inch)

Equipment Installation

CAUTION

  • Verify that the enclosure is securely mounted to the wall prior to installing any equipment.
  • It is strongly recommended to first install equipment in the bottom of the enclosure. Heavier equipment should be installed in the bottom of the enclosure.
  • If using sliding rails with installed equipment, use caution when pulling the equipment out of the enclosure as it can cause loading to shift and increase the hazard of tipping or failing. If multiple pieces of equipment use sliding rails only slide one piece of equipment out at once.

CyberPower’s wall mount enclosures have square hole. Use the black cage nuts and black screws for square holes.

NOTE:
Please review your equipment instructions carefully before installing in the enclosure

Mounting Using Square Holes and Cage nuts

  1. Install the included black M6 cage nuts from the back of the vertical mounting rails as shown below, and press the sides of the cage nuts to make sure they have been inserted properly.
    CAUTION
    To ensure proper and secure installation, cage nuts need to be installed horizontally as shown below. Installing cage nuts in the incorrect orientation can cause injury or equipment damage.

  2. Install the equipment by screwing the included black M6 screws and cup washers into the cage nuts as shown below.

For warranty and additional information, please visit www.CyberPowerSystems.com.

Cyber Power Systems (USA), Inc.
www.cyberpower.com

For USA and Canada:

  • 4241 12th Ave East, Suite 400 Shakopee, MN 55379
  • Toll-free: 1-877-297-6937

For all other regions:
Please visit our website for local contact information.

Copyright © 2022 Cyber Power Systems (USA), Inc. All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals