MITSUBISHI ELECTRIC PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit Instruction Manual

June 13, 2024
Mitsubishi Electric

MITSUBISHI ELECTRIC Logo HEATING & AIR CONDITIONING PLA-A24EA7 & PUZ-HA24NHA1
24,000 BTU/H 3’ X 3’ CEILING CASSETTE
24,000 BTU/H HYPER-HEATING UNIVERSAL OUTDOOR

PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit

Job Name:
System Reference:
Date:
Indoor Unit…………………………… PLA-A24EA7
Outdoor Unit…………………………… PUZ-HA24NHA1

INDOOR UNIT FEATURES

  • Space-effi cient ductless installation
  • Equipped with 3D i-see Sensor® for enhanced comfort and energy effi ciency
  • Airfl ow settings for high and low ceiling applications
  • Individual vane settings for direct/indirect airfl ow control or variable airfl ow patterns
  • Knockouts for outside-air intake and branch-duct run
  • Filter indicator signal
  • Easy-to-clean, washable fi lter (optional high-effi ciency fi lter available – requires multi-function casement)
  • Built-in condensate lift mechanism
  • Ideal for retail shops, classrooms, offi ce spaces, conference centers, building lobbies, and more
  • Multiple control options available:
    ○ kumo cloud® smart device app for remote access
    ○ Third-party interface options
    ○ Wired or wireless controllers

OUTDOOR UNIT FEATURES

  • Variable speed INVERTER-driven compressor
  • Wide heating range: heating performance down to -13°F (average of 80% heating capacity)
  • High speed heating at start up: Hyper-Heating INVERTER® reduces the time for heating at start up by about half compared to standard models
  • Pre-charged with refrigerant volume for piping length up to 70 ft.
  • High pressure/temperature protection
  • Built-in base pan heater

SPECIFICATIONS: PLA-A24EA7 & PUZ-HA24NHA1

Cooling at 95°F1 Maximum Capacity BTU/H 24,000
Rated Capacity BTU/H 24,000
Minimum Capacity BTU/H 10,000
Maximum Power Input W 1,710
Rated Power Input W 1,710
Moisture Removal Pints/h 3.0
Sensible Heat Factor 0.86
Power Factor [208V / 230V] % 98.0 / 98.0
Heating at 47°F2 Maximum Capacity BTU/H 28,000
Rated Capacity BTU/H 26,000
Minimum Capacity BTU/H 10,000
Maximum Power Input W 1,900
Rated Power Input W 1,700
Power Factor [208V / 230V] % 98.0 / 98.0
Heating at 17°F3 Maximum Capacity BTU/H 26,000
Rated Capacity BTU/H 17,300
Maximum Power Input W 3,000
Rated Power Input W 1,816

Heating at 5°F4

| Maximum Capacity| BTU/H| 26,000
Maximum Power Input| W| 3,966
Heating at -13°F7| Maximum Capacity| BTU/H| 20,800
Efficiency| SEER | SEER2| 21.5 | 21.6
EER1 | EER21| 14.0 | 14.0
HSPF [IV] | HSPF2 [IV]| 11.3 | 10.0
COP at 47°F2| 4.5
COP at 17°F at Maximum Capacity3| 2.5
COP at 5°F at Maximum Capacity4| 1.9
ENERGY STAR® Certified| Yes
Electrical| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198 – 253
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Recommended Fuse/Breaker Size (Oudoor)| A| 25
Recommended Wire Size [Indoor – Outdoor]| AWG| 14
Power Supply| Indoor unit is powered by the outdoor unit
Indoor Unit| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.49
Fan Motor Type| DC Motor
Airflow Rate at Cooling, Dry| CFM| 530–640–710–810
Airflow Rate at Cooling, Wet| CFM| 490–600–670–770
Airflow Rate at Heating, Dry| CFM| 530–640–710–810
Sound Pressure Level [Cooling]| dB[A]| 28–30–33–36
Sound Pressure Level [Heating]| dB[A]| 28–30–33–36
Drain Pipe Size| In. [mm]| 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance| In. [mm]| 33-7/16 [849]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 6.4Y 8.9/0.4
Unit Dimensions| W x D x H: In. [mm]| 33-1/16 // 37-13/32 x 33-1/16 // 37-13/32 x 11-3/4 // 1-9/16 [840 //

950 x 840 // 950 x 298 // 40]

Package Dimensions| W x D x H: In. [mm]| 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 16-9/16 // 4-12/16 [903 //

1,000 x 871 // 970 x 421 // 121]

Unit Weight| Lbs. [kg]| 56 // 11 [25 // 5]
Package Weight| Lbs. [kg]| 68 [31]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum / Minimum]*| °F| 90 DB, 72 WB / 66 DB, 61 WB
Heating Intake Air Temp [Maximum / Minimum]| °F| 77 DB / 59 DB

NOTES:
AHRI Rated Conditions
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed)
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions 4 Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 7
Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):

    • Wind baffles required to operate below 23°F DB in cooling mode.
    • Refer to wind baffle documentation for further information.

**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):

  •  System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
Outdoor Unit MCA A 17.0
MOCP A 27
Fan Motor Output W 74
Airflow Rate [Cooling / Heating] CFM 1940 / 1940
Refrigerant Control LEV
Defrost Method Reverse Cycle
Sound Pressure Level, Cooling1 dB(A) 52
Sound Pressure Level, Heating2 dB(A) 53
Compressor Type Scroll
Compressor Model DNB28FBAMT
Compressor Rated Load Amps A 9
Compressor Locked Rotor Amps A 18.0
Compressor Oil [Type // Charge] oz. FVC68D // 34
External Finish Color Ivory Munsell 3Y 7.8/1.1
Base Pan Heater Built-in
Unit Dimensions W x D x H: In. [mm] 37-13/32 x 14-3/16 x 37-1/8 [950 x 360 x

943]
Package Dimensions| W x D x H: In. [mm]| 41 x 18 x 41 [1040 x 450 x 1033]
Unit Weight| Lbs. [kg]| 190 [86]
Package Weight| Lbs. [kg]| 210 [95]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum / Minimum]*| °F| 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum]| °F| 70 DB, 59 WB / -13 DB, -13 WB
Heating Thermal Lock-out / Re-start Temperatures**| °F| -22 / -13
Refrigerant| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 7.0, 11.0
Maximum Pre-Charged Piping Length| Ft. [m]| 70.0 [21.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 0.7 [65]
Piping| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Maximum Piping Length| Ft. [m]| 165 [50]
Maximum Height Difference| Ft. [m]| 100 [30]
Maximum Number of Bends| 15

NOTES:
AHRI Rated Conditions 1 Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
(Rated data is determined at a fixed compressor speed) 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions 4 Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
7 Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB

  • Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):

    •  Wind baffles required to operate below 23°F DB in cooling mode.
    • Refer to wind baffle documentation for further information.

**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):

  • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

INDOOR UNIT ACCESSORIES: PLA-A24EA7

Control Interface 3-Pin Connector PAC-715AD
Airzone ZBS Wired Blueface Principal Controller White AZZBSBLUEFACECB
Airzone ZBS Wired Blueface Principal Controller White AZZBSBLUEZEROCB
Airzone ZBS Wired Lite Controller White AZZBSLITECB
Airzone ZBS Wireless Lite Controller White AZZBSLITERB
Airzone ZBS Wireless Think Controller White AZZBSTHINKRB
BACnet® and Modbus® Interface PAC-UKPRC001-CN-1
CN24 Relay Kit CN24RELAY-KIT-CM3
IT Extender PAC-WHS01IE-E
kumo station® for kumo cloud® PAC-WHS01HC-E
Remote Operation Adapter‡ PAC-SF40RM-E
Thermostat Interface PAC-US445CN-1
USNAP Adapter PAC-WHS01UP-E
Wireless Interface for kumo cloud® PAC-USWHS002-WF-2
Remote Sensor Flush Mount Remote Temperature Sensor PAC-USSEN002-FM-1
Flush Mount Temperature Sensor PAC-USSEN001-FM-1
Remote Temperature Sensor PAC-SE41TS-E
Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1
Wired Remote Controller Deluxe Wired MA Remote Controller† PAR-40MAAU
Simple MA Remote Controller† PAC-YT53CRAU-J
Touch MA Controller† PAR-CT01MAU-SB
Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller MHK2
Lockdown bracket for remote controller RCMKP1CB
Wireless MA Receiver PAR-FA32MA-W
Wireless MA Remote Controller PAR-FL32MA-E
Wireless Remote Contoller PAR-SL101A-E
Wireless Signal Receiver Panel PAR-SR4LU-E
Casement Multi-function Casement PAC-SJ41TM-E
Condensate Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor
(208/230V) [recommended] X87-721
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor

X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| COMBI

Disconnect Switch

| (30A/600V/UL) [fits 2” X 4” utility box] – Black| TAZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| TAZ-MS303W
Filter| High Efficiency Filter Element**| PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| PLP-41EAEU
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-65
Shutter Plate| Shutter Plate| PAC-SJ37SP-E
Space Panel| Space Panel| PAC-SJ38AS-E

NOTES: ‡ PAC-SF40RM-E (Unable to use with wireless remote controller)

OUTDOOR UNIT ACCESSORIES: PUZ-HA24NHA1

Air Outlet Guide Air Outlet Guide (1 Piece) PAC-SG59SG-E
Control/Service Tool Control/Service Tool PAC-SK52ST
Hail Guards Hail Guard HG-A6

M-NET Converter

| M-NET Converter| PAC-SJ85MA-E
M-NET Converter| PAC-SJ95MA-E
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| ULTRILITE2
Stand| 18” Single Fan Stand| QSMS1801M
24” Single Fan Stand| QSMS2401M
Condenser Wall Bracket| QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| QSWBSS
Outdoor Unit Stand — 12” High| QSMS1201M
Wind Baffle| Front Wind Baffle| WB-PA5
Rear Wind Baffle| WB-RE5
Side Advanced Wind Baffle| WB-SD5

INDOOR UNIT DIMENSIONS: PLA-A24EA7

MITSUBISHI ELECTRIC PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit -
Fig

NOTE

  1. CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES.
  2. REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.
  3. FOR THE SUSPENSION BOLT. USE MIO OR W318. (PROCURED AT THE LOCAL SITE.)
  4. FOR DRAIN PIPE, USE VP-25(0.D. n1-1/4″(1 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-1/16,850mm) FROM THE CEILING.
  5. ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITRE BIT FOR CONTROUPOWER WIRES CONNECTION.
  6. THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED.
  7. REQUIRES “E” OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION.
  8. WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)
  9. AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.
  10. FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING.

MODELS| (i)| (?)| A| B| C| D| E| F
---|---|---|---|---|---|---|---|---
12118 KBTU/H| REFRIGERANT PIPE06.35 FLARED CONVECTION 114F| REFRIGERANT PIPE1 12.7 FLARED CONNECTION 112F| 9-1/2
(241)| 10-3116
(258)| 3(76)| 3(76.5)| 10-7/16(265) OR MORE| 137-13/16(3500) OR LESS
24130/36/42 KBTLI1E1| REFRIGERANT PIPE09.52 FLARED CONNECTION 318F| REFRIGERANT PIPE( 15.88 FLARED CONNECTION 518F| 11-1/16
(281)| 11-3/4
(298)| 3 118
(79.5)| 12(305) OR MORE| 177-3116(4500) OR LESS

OUTDOOR UNIT DIMENSIONS: PUZ-HA24NHA1

MITSUBISHI ELECTRIC PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit - Fig
1

1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822 www.mehvac.com

MITSUBISHI ELECTRIC PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit -
IconMITSUBISHI ELECTRIC
Logo FORM# PLA-A24EA7 & PUZ-HA24NHA1 – 202303
Specifications are subject to change without notice.
© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Documents / Resources

| MITSUBISHI ELECTRIC PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit [pdf] Instruction Manual
PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit, PLA-A24EA7R1.TH, Ceiling Cassette Indoor Unit, Cassette Indoor Unit, Indoor Unit, Unit
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals