HEATING & AIR CONDITIONING PLA-A24EA7 &
PUZ-HA24NHA1
24,000 BTU/H 3’ X 3’ CEILING CASSETTE
24,000 BTU/H HYPER-HEATING UNIVERSAL OUTDOOR
PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit
Job Name:
System Reference:
Date:
Indoor Unit…………………………… PLA-A24EA7
Outdoor Unit…………………………… PUZ-HA24NHA1
INDOOR UNIT FEATURES
- Space-effi cient ductless installation
- Equipped with 3D i-see Sensor® for enhanced comfort and energy effi ciency
- Airfl ow settings for high and low ceiling applications
- Individual vane settings for direct/indirect airfl ow control or variable airfl ow patterns
- Knockouts for outside-air intake and branch-duct run
- Filter indicator signal
- Easy-to-clean, washable fi lter (optional high-effi ciency fi lter available – requires multi-function casement)
- Built-in condensate lift mechanism
- Ideal for retail shops, classrooms, offi ce spaces, conference centers, building lobbies, and more
- Multiple control options available:
○ kumo cloud® smart device app for remote access
○ Third-party interface options
○ Wired or wireless controllers
OUTDOOR UNIT FEATURES
- Variable speed INVERTER-driven compressor
- Wide heating range: heating performance down to -13°F (average of 80% heating capacity)
- High speed heating at start up: Hyper-Heating INVERTER® reduces the time for heating at start up by about half compared to standard models
- Pre-charged with refrigerant volume for piping length up to 70 ft.
- High pressure/temperature protection
- Built-in base pan heater
SPECIFICATIONS: PLA-A24EA7 & PUZ-HA24NHA1
Cooling at 95°F1 | Maximum Capacity | BTU/H | 24,000 |
---|---|---|---|
Rated Capacity | BTU/H | 24,000 | |
Minimum Capacity | BTU/H | 10,000 | |
Maximum Power Input | W | 1,710 | |
Rated Power Input | W | 1,710 | |
Moisture Removal | Pints/h | 3.0 | |
Sensible Heat Factor | 0.86 | ||
Power Factor [208V / 230V] | % | 98.0 / 98.0 | |
Heating at 47°F2 | Maximum Capacity | BTU/H | 28,000 |
Rated Capacity | BTU/H | 26,000 | |
Minimum Capacity | BTU/H | 10,000 | |
Maximum Power Input | W | 1,900 | |
Rated Power Input | W | 1,700 | |
Power Factor [208V / 230V] | % | 98.0 / 98.0 | |
Heating at 17°F3 | Maximum Capacity | BTU/H | 26,000 |
Rated Capacity | BTU/H | 17,300 | |
Maximum Power Input | W | 3,000 | |
Rated Power Input | W | 1,816 |
Heating at 5°F4
| Maximum Capacity| BTU/H| 26,000
Maximum Power Input| W| 3,966
Heating at -13°F7| Maximum Capacity| BTU/H| 20,800
Efficiency| SEER | SEER2| 21.5 | 21.6
EER1 | EER21| 14.0 | 14.0
HSPF [IV] | HSPF2 [IV]| 11.3 | 10.0
COP at 47°F2| 4.5
COP at 17°F at Maximum Capacity3| 2.5
COP at 5°F at Maximum Capacity4| 1.9
ENERGY STAR® Certified| Yes
Electrical| Voltage, Phase, Frequency| 208/230, 1, 60
Guaranteed Voltage Range| V AC| 198 – 253
Voltage: Indoor – Outdoor, S1-S2| V AC| 208/230
Voltage: Indoor – Outdoor, S2-S3| V DC| 24
Short-circuit Current Rating [SCCR]| kA| 5
Recommended Fuse/Breaker Size (Oudoor)| A| 25
Recommended Wire Size [Indoor – Outdoor]| AWG| 14
Power Supply| Indoor unit is powered by the outdoor unit
Indoor Unit| MCA| A| 1.0
Fan Motor Full Load Amperage| A| 0.49
Fan Motor Type| DC Motor
Airflow Rate at Cooling, Dry| CFM| 530–640–710–810
Airflow Rate at Cooling, Wet| CFM| 490–600–670–770
Airflow Rate at Heating, Dry| CFM| 530–640–710–810
Sound Pressure Level [Cooling]| dB[A]| 28–30–33–36
Sound Pressure Level [Heating]| dB[A]| 28–30–33–36
Drain Pipe Size| In. [mm]| 1-1/4 [32]
Condensate Lift Mechanism, Maximum Distance| In. [mm]| 33-7/16 [849]
Coating on Heat Exchanger| —
External Finish Color| White Munsell 6.4Y 8.9/0.4
Unit Dimensions| W x D x H: In. [mm]| 33-1/16 // 37-13/32 x 33-1/16 //
37-13/32 x 11-3/4 // 1-9/16 [840 //
950 x 840 // 950 x 298 // 40]
Package Dimensions| W x D x H: In. [mm]| 35-9/16 // 39-6/16 x 34-5/16 // 38-3/16 x 16-9/16 // 4-12/16 [903 //
1,000 x 871 // 970 x 421 // 121]
Unit Weight| Lbs. [kg]| 56 // 11 [25 // 5]
Package Weight| Lbs. [kg]| 68 [31]
Indoor Unit Operating Temperature Range| Cooling Intake Air Temp [Maximum /
Minimum]*| °F| 90 DB, 72 WB / 66 DB, 61 WB
Heating Intake Air Temp [Maximum / Minimum]| °F| 77 DB / 59 DB
NOTES:
AHRI Rated Conditions
Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is
determined at a fixed compressor speed)
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions 4 Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
7
Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB
-
Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Wind baffles required to operate below 23°F DB in cooling mode.
- Refer to wind baffle documentation for further information.
**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
Outdoor Unit | MCA | A | 17.0 |
---|---|---|---|
MOCP | A | 27 | |
Fan Motor Output | W | 74 | |
Airflow Rate [Cooling / Heating] | CFM | 1940 / 1940 | |
Refrigerant Control | LEV | ||
Defrost Method | Reverse Cycle | ||
Sound Pressure Level, Cooling1 | dB(A) | 52 | |
Sound Pressure Level, Heating2 | dB(A) | 53 | |
Compressor Type | Scroll | ||
Compressor Model | DNB28FBAMT | ||
Compressor Rated Load Amps | A | 9 | |
Compressor Locked Rotor Amps | A | 18.0 | |
Compressor Oil [Type // Charge] | oz. | FVC68D // 34 | |
External Finish Color | Ivory Munsell 3Y 7.8/1.1 | ||
Base Pan Heater | Built-in | ||
Unit Dimensions | W x D x H: In. [mm] | 37-13/32 x 14-3/16 x 37-1/8 [950 x 360 x |
943]
Package Dimensions| W x D x H: In. [mm]| 41 x 18 x 41 [1040 x 450 x 1033]
Unit Weight| Lbs. [kg]| 190 [86]
Package Weight| Lbs. [kg]| 210 [95]
Outdoor Unit Operating Temperature Range| Cooling Air Temp [Maximum /
Minimum]*| °F| 115 DB / 0 DB
Heating Air Temp [Maximum / Minimum]| °F| 70 DB, 59 WB / -13 DB, -13 WB
Heating Thermal Lock-out / Re-start Temperatures**| °F| -22 / -13
Refrigerant| Type| R410A
Pre-Charged Refrigerant Amount| Lbs, oz| 7.0, 11.0
Maximum Pre-Charged Piping Length| Ft. [m]| 70.0 [21.0]
Additional Refrigerant Charge Per Additional Piping Length| oz./Ft. [g/m]| 0.7
[65]
Piping| Gas Pipe Size O.D. [Flared]| In.[mm]| 5/8 [15.88]
Liquid Pipe Size O.D. [Flared]| In.[mm]| 3/8 [9.52]
Maximum Piping Length| Ft. [m]| 165 [50]
Maximum Height Difference| Ft. [m]| 100 [30]
Maximum Number of Bends| 15
NOTES:
AHRI Rated Conditions 1 Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB,
75 WB
(Rated data is determined at a fixed compressor speed) 2
Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3
Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB
Conditions 4 Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB
7 Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB
-
Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
- Wind baffles required to operate below 23°F DB in cooling mode.
- Refer to wind baffle documentation for further information.
**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re- start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
- System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
INDOOR UNIT ACCESSORIES: PLA-A24EA7
Control Interface | 3-Pin Connector | PAC-715AD |
---|---|---|
Airzone ZBS Wired Blueface Principal Controller White | AZZBSBLUEFACECB | |
Airzone ZBS Wired Blueface Principal Controller White | AZZBSBLUEZEROCB | |
Airzone ZBS Wired Lite Controller White | AZZBSLITECB | |
Airzone ZBS Wireless Lite Controller White | AZZBSLITERB | |
Airzone ZBS Wireless Think Controller White | AZZBSTHINKRB | |
BACnet® and Modbus® Interface | PAC-UKPRC001-CN-1 | |
CN24 Relay Kit | CN24RELAY-KIT-CM3 | |
IT Extender | PAC-WHS01IE-E | |
kumo station® for kumo cloud® | PAC-WHS01HC-E | |
Remote Operation Adapter‡ | PAC-SF40RM-E | |
Thermostat Interface | PAC-US445CN-1 | |
USNAP Adapter | PAC-WHS01UP-E | |
Wireless Interface for kumo cloud® | PAC-USWHS002-WF-2 | |
Remote Sensor | Flush Mount Remote Temperature Sensor | PAC-USSEN002-FM-1 |
Flush Mount Temperature Sensor | PAC-USSEN001-FM-1 | |
Remote Temperature Sensor | PAC-SE41TS-E | |
Wireless temperature and humitity sensor for kumo cloud® | PAC-USWHS003-TH-1 | |
Wired Remote Controller | Deluxe Wired MA Remote Controller† | PAR-40MAAU |
Simple MA Remote Controller† | PAC-YT53CRAU-J | |
Touch MA Controller† | PAR-CT01MAU-SB | |
Wireless Remote Controller | kumo touch™ RedLINK™ Wireless Controller | MHK2 |
Lockdown bracket for remote controller | RCMKP1CB | |
Wireless MA Receiver | PAR-FA32MA-W | |
Wireless MA Remote Controller | PAR-FL32MA-E | |
Wireless Remote Contoller | PAR-SL101A-E | |
Wireless Signal Receiver Panel | PAR-SR4LU-E | |
Casement | Multi-function Casement | PAC-SJ41TM-E |
Condensate | Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor | |
(208/230V) [recommended] | X87-721 | |
Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor |
X87-835
Blue Diamond Sensor Extension Cable — 15 Ft.| C13-103
Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H| COMBI
Disconnect Switch
| (30A/600V/UL) [fits 2” X 4” utility box] – Black| TAZ-MS303
(30A/600V/UL) [fits 2” X 4” utility box] – White| TAZ-MS303W
Filter| High Efficiency Filter Element**| PAC-SH59KF-E
i-see Sensor® Panel| Grille with 3D i-see Sensor® (required)| PLP-41EAEU
Lineset| 10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation)|
MPLS385812T-10
100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-100
15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-15
30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-30
50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-50
65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation)| MPLS385812T-65
Shutter Plate| Shutter Plate| PAC-SJ37SP-E
Space Panel| Space Panel| PAC-SJ38AS-E
NOTES: ‡ PAC-SF40RM-E (Unable to use with wireless remote controller)
OUTDOOR UNIT ACCESSORIES: PUZ-HA24NHA1
Air Outlet Guide | Air Outlet Guide (1 Piece) | PAC-SG59SG-E |
---|---|---|
Control/Service Tool | Control/Service Tool | PAC-SK52ST |
Hail Guards | Hail Guard | HG-A6 |
M-NET Converter
| M-NET Converter| PAC-SJ85MA-E
M-NET Converter| PAC-SJ95MA-E
Mounting Pad| Condensing Unit Mounting Pad: 24” x 42” x 3”| ULTRILITE2
Stand| 18” Single Fan Stand| QSMS1801M
24” Single Fan Stand| QSMS2401M
Condenser Wall Bracket| QSWB2000M-1
Condenser Wall Bracket – Stainless Steel Finish| QSWBSS
Outdoor Unit Stand — 12” High| QSMS1201M
Wind Baffle| Front Wind Baffle| WB-PA5
Rear Wind Baffle| WB-RE5
Side Advanced Wind Baffle| WB-SD5
INDOOR UNIT DIMENSIONS: PLA-A24EA7
NOTE
- CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES.
- REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.
- FOR THE SUSPENSION BOLT. USE MIO OR W318. (PROCURED AT THE LOCAL SITE.)
- FOR DRAIN PIPE, USE VP-25(0.D. n1-1/4″(1 32) PVC TUBE). DRAIN PUMP INCLUSION. RAISE IS MAX 33-1/16,850mm) FROM THE CEILING.
- ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE. MAKE SURE TO SLACK THE ELECTRICAL WIRE LITRE BIT FOR CONTROUPOWER WIRES CONNECTION.
- THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED WITH THE GRILLE ATTACHED.
- REQUIRES “E” OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION.
- WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY. OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR. (IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)
- AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.
- FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER OR MULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING.
MODELS| (i)| (?)| A| B| C| D| E|
F
---|---|---|---|---|---|---|---|---
12118 KBTU/H| REFRIGERANT PIPE06.35 FLARED CONVECTION 114F| REFRIGERANT PIPE1
12.7 FLARED CONNECTION 112F| 9-1/2
(241)| 10-3116
(258)| 3(76)| 3(76.5)| 10-7/16(265) OR MORE| 137-13/16(3500) OR LESS
24130/36/42 KBTLI1E1| REFRIGERANT PIPE09.52 FLARED CONNECTION 318F|
REFRIGERANT PIPE( 15.88 FLARED CONNECTION 518F| 11-1/16
(281)| 11-3/4
(298)| 3 118
(79.5)| 12(305) OR MORE| 177-3116(4500) OR LESS
OUTDOOR UNIT DIMENSIONS: PUZ-HA24NHA1
1340 Satellite Boulevard Suwanee, GA 30024
Toll Free: 800-433-4822
www.mehvac.com
FORM# PLA-A24EA7 & PUZ-HA24NHA1 – 202303
Specifications are subject to change without notice.
© 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Documents / Resources
|
MITSUBISHI ELECTRIC PLA-A24EA7R1.TH Ceiling Cassette Indoor
Unit
[pdf] Instruction Manual
PLA-A24EA7R1.TH Ceiling Cassette Indoor Unit, PLA-A24EA7R1.TH, Ceiling
Cassette Indoor Unit, Cassette Indoor Unit, Indoor Unit, Unit
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>