saxby lighting 92273 LED White Panel Light Instruction Manual
- June 13, 2024
- saxby lighting
Table of Contents
Saxby Lighting 92273 LED White Panel Light
Product Information
- Supply Voltage: 220-240 V~, 50 Hz
- Operational Voltage: 33-40V DC
- Bulb Types:
- 92273: 40W LED (SMD), 4000K, energy efficiency class E
- 92274: 40W LED (SMD), 6000K, energy efficiency class E
- 92543: 40W LED (SMD) CCT, 3000K/4000K/6000K, energy efficiency class E
- Light Source: Non-replaceable
- Control Gear: Replaceable by a professional
- Conformity: Conforms with all relevant UKCA Directive requirements and EC Directive requirements
- Power Supply: Double insulated, does not require connection to an earth circuit
- Panel Light Class: Class III product, designed to be supplied via a transformer
- Disposal: Waste electrical products should be recycled, check with Local Authority or local store for recycling advice
- Dimming: This product is not suitable for dimming
- IP Rating:
- IP40 for 92273, 92274
- IP44 for 92543
- Accessories Available:
- Surface Mount Kit – 81850: Allows the panels to be mounted to the ceiling when not being used in a suspended ceiling
- Suspension Kit – 81744: Allows the panels to be suspended up to 1 meter from the ceiling
- Recess Clip – 91237: One set of recess clips (4pcs) is required for recessed mount on alternative ceilings. Installation details are available in the instruction manual of the Recess Clip
- Manufacturer: UK Manufacturer: BH17 7BY, EU Manufacturer: Brilliant AG, Brilliantstrasse 1, D-27442 Warrensburg
- Website: https://www.lighting-info.co.uk/92273
Product Usage Instructions
- Warning: Before installation, ensure that existing fittings are completely removed. Take note of the position of each set of wires and ensure that the switch is turned off.
- For 92543: This product is color-changing and can be set to warm white (3000K), cool white (4000K), or daylight white (6000K). Choose your preferred color before installing it by using the inline switch.
- Suspended Ceiling: If using a suspended ceiling, ensure that the product is properly installed and not fouling any of the supporting bars (See Fig. 3).
- Wiring: Identify the wiring from your existing light fitting and pull the main wire through the hole. Connect it to the connection block inside the LED driver as follows:
- This unit is double-insulated and must not be earthed.
- If there are any incoming earth cables, they must be joined together and well-insulated with good-quality insulation tape to ensure earth continuity throughout your property.
- Cleaning and Safety: Clean the product with a soft dry cloth. Do not use solvents or abrasive cleaners as they could damage the finish. Always switch off the power supply before cleaning for safety.
- Retaining Instructions: Please retain these instructions for future reference.
Thank you for purchasing this light fitting. Please read the instruction carefully before use to ensure the safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated and does not require connection to an
Earth circuit.
- Please read these instructions carefully before commencing any work
- This unit must be fitted by a competent and qualified electrician.
- Install in accordance with the IEE Wiring regulations and current Building Regulations.
- Check the pack and make sure you have all the parts listed.
- To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
- This light fitting should be connected to a fused circuit.
- If replacing an existing fitting, make a careful note of the connections.
- The part of the panel light at Safety Extra Low Voltage (33-40V DC ) via a transformer.
- Never connect the light fittings directly to the mains without using a transformer.
- This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped. Dimmable only when used in conjunction with suitable dimmable drivers.
- Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between the LED Driver and each light fitting. Ensure that
there is adequate ventilation for the LED Driver. Avoid locating any cables in
positions that would cause a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk of being cut, trapped, or
damaged. The main supply cable must have a minimum cross-section area of
1.0mm2. Cables must be protected using suitable conduit or plastic trunking.
These fittings are designed to be fitted into a suspended ceiling. Panels are
rated as TPA according to Building Regulations B2.
- If there is a ceiling tile in position then ensure that it is removed (See Fig. 1).
- Wire the LED driver as shown below and connect the driver cable to the panel using the push & twist connector (See Fig. 2)
- Place panel fitting into the ceiling. Ensure that the fitting is sitting properly on the T bar of the suspended ceiling and is not fouling any of the supporting bars (See Fig. 3).
Wiring
Having correctly identified the wiring from your existing light fitting, pull
the mains wire through the hole and connect to the connection block inside the
LED driver in the following way: This unit is double insulated and must not be
earthed. If there are any incoming earth cables, they must be joined together
and well-insulated with good-quality insulation tape. This is to ensure earth
continuity throughout your property.
Check that…
You have correctly identified the wires. The connections are tight. No loose
strands have been left out of the connection block.
Commissioning
Ensure that the product is sitting properly on the suspended ceiling frame (see Fig. 4). Replace any other ceiling tiles. Replace the fuse or circuit breaker and switch it on. Your light is now ready for use.
Installation
Existing fittings must be completely removed before the installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires. Note that the switch is turned off before installation. For 92543, this product is color-changing and can be either warm white (3000K) or cool white (4000K), or daylight white (6000K). Choose your preferred color before installing by using the inline switch.
Technical data
Accessories available
Surface mount kit – 81850
This kit will allow the panels to be mounted to the ceiling when not being
used in a suspended ceiling.
Suspension kit – 81744
This kit will allow the panels to be suspended up to 1 meter from the ceiling.
Recess clip – 91237
One set recess clip (4pcs) is required for recessed mount on alternative
ceilings. For installation details please refer to the instruction manual of
Recess Clip.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners as these could damage the finish. For your safety, always switch off
the power supply before cleaning.
For further information, please visit https://www.lighting-info.co.uk/92273
V6 10/03/2023
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG, Brilliantstrasse 1, D-27442 Gnarrenburg
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>