NOVUS 70 Telik Gardo Reader User Guide
- June 13, 2024
- Novus
Table of Contents
70 Telik Gardo Reader
Product Information
The Telik Gardo Reader is a product manufactured by Novus
Automation. It is a device used for reading and monitoring data
from various sources. The reader supports communication interfaces
such as USB and RS485, allowing for easy connectivity to a computer
or other devices.
1. Safety Alerts
This section of the user guide provides important safety
information and precautions that should be followed while using the
Telik Gardo Reader. It is essential to read and understand these
alerts before proceeding with installation and usage.
2. Introduction
This section provides an overview of the Telik Gardo Reader and
its functionalities. It gives users an understanding of what the
product is capable of and how it can be beneficial in various
applications.
3. Installation
This section covers the installation process for the Telik Gardo
Reader. It includes electrical installation recommendations, power
supply connections, mechanical installation guidelines, and
communication interface setup instructions.
3.1 Electrical Installation
This subsection provides recommendations for the electrical
installation of the Telik Gardo Reader. It advises on best
practices and precautions to ensure proper functioning and
safety.
3.2 Mechanical Installation
This subsection guides users on how to physically install the
Telik Gardo Reader. It includes instructions on positioning and
mounting the device securely.
3.3 Communication Interfaces
This subsection explains the available communication interfaces
supported by the Telik Gardo Reader, specifically USB and RS485. It
provides instructions on how to connect the reader to other devices
using these interfaces.
4. How to Install the Configuration Software
This section explains the steps required to install the
configuration software for the Telik Gardo Reader.
4.1 Install the USB Driver
This subsection provides instructions on how to install the USB
driver needed for the Telik Gardo Reader to communicate with a
computer via the USB interface.
4.2 Install the Configurator Software
This subsection guides users through the installation process of
the configurator software, which enables users to configure and
manage the Telik Gardo Reader.
4.3 Connect the Device to the Computer
This subsection outlines the steps to connect the Telik Gardo
Reader to a computer after installing the necessary software. It
ensures a successful connection and communication between the
reader and the computer.
5. How to Use the Telik Gardo Software
This section provides instructions on how to use the Telik Gardo
software that comes with the reader. It covers the initial run of
the software and explains the user interface.
5.1 Software Initial Run
This subsection describes the steps to follow when running the
Telik Gardo software for the first time. It ensures a smooth start
and proper configuration of the software.
5.2 Telik Gardo Software Interface
This subsection provides an overview of the user interface of
the Telik Gardo software. It explains the different features and
functionalities available for data reading and monitoring.
6. Modbus-RTU Protocol
This section explains the Modbus-RTU protocol, which is
supported by the Telik Gardo Reader. It provides information on how
to use this protocol for communication purposes.
Product Usage Instructions
To use the Telik Gardo Reader, please follow the below
instructions:
-
Read and understand the safety alerts provided in the user
guide. -
Follow the installation instructions, including electrical and
mechanical installation guidelines. -
Connect the Telik Gardo Reader to a power supply using the
recommended power supply connections. -
If using the USB interface, install the USB driver on your
computer following the instructions provided in the user
guide. -
Install the configurator software on your computer by following
the provided instructions. -
Connect the Telik Gardo Reader to your computer using the
appropriate communication interface (USB or RS485). -
Run the Telik Gardo software on your computer, following the
initial run instructions provided in the user guide. -
Familiarize yourself with the Telik Gardo software interface
and utilize its features for data reading and monitoring. -
If utilizing the Modbus-RTU protocol, refer to the user guide
for information on how to use this protocol for communication
purposes.
By following these instructions, you will be able to
successfully install and use the Telik Gardo Reader for data
reading and monitoring purposes.
TELIK GARDO READER
USER GUIDE V1.0x B
NOVUS AUTOMATION
1/21
1 SAFETY ALERTS ………………………………………………………………………………………………………………………………………………………3
2 INTRODUCTION ………………………………………………………………………………………………………………………………………………………..4
2.1 DEVICE………………………………………………………………………………………………………………………………………………………………4 2.2
ANTENNA…………………………………………………………………………………………………………………………………………………………..4 2.3
SENSORS ………………………………………………………………………………………………………………………………………………………….4
3 INSTALLATION …………………………………………………………………………………………………………………………………………………………5
3.1 ELECTRICAL INSTALLATION ………………………………………………………………………………………………………………………………5
3.1.1 INSTALLATION RECOMMENDATIONS ………………………………………………………………………………………………………….5
3.1.2 POWER SUPPLY CONNECTIONS…………………………………………………………………………………………………………………5
3.2 DIMENSIONS ……………………………………………………………………………………………………………………………………………………..5
3.2.1 TELIK GARDO……………………………………………………………………………………………………………………………………………..5
3.2.2 TELIK GARDO ANTENNA……………………………………………………………………………………………………………………………..5
3.2.3 TELIK GARDO SENSOR……………………………………………………………………………………………………………………………….6
3.3 MECHANICAL INSTALLATION……………………………………………………………………………………………………………………………..6
3.4 COMMUNICATION INTERFACES …………………………………………………………………………………………………………………………6
3.4.1 USB INTERFACE …………………………………………………………………………………………………………………………………………6
3.4.2 RS485 INTERFACE………………………………………………………………………………………………………………………………………6
4 HOW TO INSTALL THE CONFIGURATION
SOFTWARE……………………………………………………………………………………………….7
4.1 INSTALL THE USB DRIVER …………………………………………………………………………………………………………………………………7
4.2 INSTALL THE CONFIGURATOR
SOFTWARE………………………………………………………………………………………………………..7 4.3 CONNECT THE DEVICE TO
THE COMPUTER………………………………………………………………………………………………………7
5 HOW TO USE THE TELIK GARDO SOFTWARE
…………………………………………………………………………………………………………..8
5.1 SOFTWARE INITIAL RUN…………………………………………………………………………………………………………………………………….8
5.2 TELIK GARDO SOFTWARE INTERFACE ………………………………………………………………………………………………………………9
5.2.1 SOFTWARE VERSION …………………………………………………………………………………………………………………………………9
5.2.2 PANEL WITH CONFIGURATION FUNCTIONS………………………………………………………………………………………………10
5.2.3 DISPLAYING TEMPERATURE DATA FOR THE
SENSOR………………………………………………………………………………10 5.2.4 SELECTION OF THE RELATED USB
COMMUNICATION PORT …………………………………………………………………….10 5.2.5 REAL-TIME DATA
COLLECTION FUNCTION………………………………………………………………………………………………..10 5.2.6 FIRMWARE
VERSION ………………………………………………………………………………………………………………………………..11 5.2.7 START/STOP
SENSOR READING……………………………………………………………………………………………………………….11 5.3 HOW TO
CONFIGURE THE P1 SENSORID INTERFACE………………………………………………………………………………………11 5.4 HOW
TO PERFORM A BASIC CONFIGURATION…………………………………………………………………………………………………13 5.5
HOW TO CONFIGURE THE ANTENNAS……………………………………………………………………………………………………………..13 5.6
HOW TO USE THE TOOLBAR ……………………………………………………………………………………………………………………………14 5.6.1
TOOLBAR………………………………………………………………………………………………………………………………………………….14 5.6.2 RF
CTRL INTERFACE INSTRUCTIONS ……………………………………………………………………………………………………….15 5.6.3
FIRMWARE DOWNLOAD INTERFACE INSTRUCTIONS ………………………………………………………………………………..15
6 MODBUS-RTU PROTOCOL ………………………………………………………………………………………………………………………………………17
6.1 COMMANDS……………………………………………………………………………………………………………………………………………………..17 6.2
REGISTERS TABLE…………………………………………………………………………………………………………………………………………..17
6.2.1 RELATIVE HUMIDITY INFORMATION (OPTIONAL)
………………………………………………………………………………………18
7 TECHNICAL SPECIFICATIONS …………………………………………………………………………………………………………………………………19
7.1 CERTIFICATIONS ……………………………………………………………………………………………………………………………………………..19
8 WARRANTY …………………………………………………………………………………………………………………………………………………………….21
NOVUS AUTOMATION
2/21
1 SAFETY ALERTS
The following symbols are used on the equipment and throughout this manual to
draw the user’s attention to valuable information related to the safety and
use of the equipment.
CAUTION
Read the manual completely before installing and operating the equipment.
CAUTION OR HAZARD Risk of electric shock.
ATTENTION
Material sensitive to static charge. Be sure to take proper precautions before
handling it.
All safety recommendations appearing in this manual must be followed to ensure personal safety and prevent damage to the instrument or system. If the instrument is used in a manner other than that specified in this manual, the device safety protections may not be effective.
NOVUS AUTOMATION
3/21
2 INTRODUCTION
Some of the main challenges for electric power distribution companies involve
uninterrupted power supply and the need to meet the requirements of regulatory
agencies regarding the quality of electricity supply. Therefore, it is
necessary to monitor the most critical components of power substations to
ensure their integrity. Since an unusual temperature rise can be seen as an
early warning indicator of anomaly or asset degradation, NOVUS has launched
the Telik Gardo kit, a remote temperature monitoring system that allows you to
view information online and manage the maintenance process. Using wireless
temperature sensors, Telik Gardo Reader is easy to install and deploy. It can
be integrated into any SCADA system or any cloud platform using an IoT
Gateway.
2.1 DEVICE
This is the Telik Gardo Reader:
Figure 1 Telik Gardo Reader Ideal for DIN rail installation, the device
allows you to collect data, read temperature information, and perform
continuous monitoring of power substations.
2.2 ANTENNA
This is the Telik Gardo Antenna:
Figure 2 Telik Gardo Antenna The antenna must be attached to the wall by
using two screws or connected to the surface by using the magnets. Connected
to the antenna, you must install the Telik Gardo Cable, which is 3 meters
long.
2.3 SENSORS
These are the Telik Gardo Sensors:
Figure 3 Telik Gardo Sensor
The sensors must be installed close to the place to be monitored, fixed with a
screw or cable ties. Since they are passive sensors, they do not require
batteries.
NOVUS AUTOMATION
4/21
3 INSTALLATION 3.1 ELECTRICAL INSTALLATION
3.1.1 INSTALLATION RECOMMENDATIONS · Electronic and analog signal conductors
must run through the plant separately from the output and supply conductors.
If possible, in grounded
conduits. · The power supply for the electronic instruments must come from a
proper instrumentation network. · It is recommended to use RC FILTERS (noise
suppressors) at contactor coils, solenoids, etc. · In control applications, it
is essential to consider what can happen when any part of the system fails.
The internal devices of the equipment do
not guarantee full protection. · The electrical connections must be made with
the connection terminals detached from the equipment. Before connecting them,
make sure that
the connections have been made correctly.
3.1.2 POWER SUPPLY CONNECTIONS You must connect the source to the device,
using the following identification:
Positive. Negative / Neutral.
Ground.
Table 1 Power supply connections
3.2 DIMENSIONS
3.2.1 TELIK GARDO The device has the following dimensions:
3.2.2 TELIK GARDO ANTENNA The antenna has the following dimensions:
Figure 4 Dimensions
Figure 5 Dimensions
NOVUS AUTOMATION
5/21
3.2.3 TELIK GARDO SENSOR The sensor has the following dimensions:
Figure 6 Dimensions
3.3 MECHANICAL INSTALLATION
Telik Gardo Reader is intended for a 35 mm DIN rail mounting. You should use
the fixing holes or the magnets to attach your antennas to the wall or desired
surface. You can attach the sensors to the electrical panel or surface by
using a screw or cable ties.
3.4 COMMUNICATION INTERFACES
3.4.1 USB INTERFACE Telik Gardo Reader has a USB interface, located on the
side of the device. The USB interface must be used to configure and perform
device diagnostics via Telik Gardo software. To connect the device to a
computer, you must use a micro-USB standard USB cable (not supplied). Before
installing the configuration software, you must install the USB interface
drivers (see HOW TO INSTALL THE CONFIGURATION SOFTWARE chapter).
The USB interface should be used temporarily to CONFIGURE and PERFORM
DIAGNOSTICS of the device.
3.4.2 RS485 INTERFACE Telik Gardo Reader has a RS485 interface, located on the
side of the device. The RS485 interface can be configured to operate at the
following speeds (Baud Rates): 1200, 2400, 4800, 9600, 19200, 38400, 57600,
and 115200. In addition, it can be configured to operate with 1 or 2 Stop Bits
and in the parities 8N1, 8N2, 8O1, or 8E1. All these parameters can be
configured through the software. The table below helps you to perform the
RS485 communication interface connection:
Inverted bidirectional data line. Bidirectional data line.
Optional connection that improves communication performance.
Table 2 RS485 Connections More details on implementing a device network via
RS485 can be found in the document “RS485 and RS422 basics”, available at
www.novusautomation.com.
NOVUS AUTOMATION
6/21
4 HOW TO INSTALL THE CONFIGURATION SOFTWARE
Telik Gardo Reader is compatible with the Telik Gardo software, used to
configure and monitor the device. To use it, you must follow the steps below.
4.1 INSTALL THE USB DRIVER
Install the USB driver to enable the computer you are using to recognize Telik
Gardo Reader via the USB interface. Simply double-click the file
CP210x_Universal_Windows_Driver, available for download from NOVUS’ product
page. To complete the installation, follow the instructions that will appear
on the screen.
4.2 INSTALL THE CONFIGURATOR SOFTWARE
Install Telik Gardo software to configure and perform data reading from Telik
Gardo Reader. The software is compatible with Windows 10 and later versions.
Simply double-click the file Reader_UT_4.0.3_Setup_NOVUS, available for
download from NOVUS’ product page. To complete the installation, follow the
instructions that will appear on the screen.
4.3 CONNECT THE DEVICE TO THE COMPUTER
Once the USB driver for the Telik Gardo Reader and the configuration software
has been installed, you can configure the device. Then you should follow the
steps below: 1. Connect the Telik Gardo Reader to a power supply (for more
information about the power supply and voltage ranges, see TECHNICAL
SPECIFICATIONS chapter). 2. Connect the device to mains power. The power
indicator light on the device should light up and flash at intervals. 3. After
installing the USB driver for the device, connect the USB cable from Telik
Gardo Reader to the computer’s USB interface. 4. Run the Telik Gardo software.
The figure below shows the communication and power interfaces of the device:
USB Interface
RS485 Power Supply Figure 7 Device interfaces
NOVUS AUTOMATION
7/21
5 HOW TO USE TELIK GARDO SOFTWARE
5.1 SOFTWARE INITIAL RUN 1. To run Telik Gardo software, double-click the
following shortcut icon on your computer desktop:
Figure 8 Software shortcut 2. After starting the software, open the Windows
“Device Manager”. Check the Ports (COM & LPT) section. In it, find the Silicon
Labs CP210X
USB to UARTBridge (COMX) device.
3. Select the USB COMX port and click Open:
Figure 9 Device manager
4. The following window will be displayed:
Figure 10 Selecting a COM port
Figure 11 Firmware version
Make sure that the parameter FW Ver. displays the version number. The example
above shows a situation where Telik Gardo Reader is properly connected.
NOVUS AUTOMATION
8/21
5. Click the Start button. The software will display messages regarding the
scanning of the sensors connected to the reader:
Figure 12 Sensor scanning If displayed, the message “Timeout” indicates that
communication between the device and the software was unsuccessful. This does
not stop the device from working but indicates that it is busy and is in
No_Resp mode.
5.2 TELIK GARDO SOFTWARE INTERFACE Once opened, the Telik Gardo software will
display the following interface:
This interface is divided into the following sections:
Figure 13 Software sections
5.2.1 SOFTWARE VERSION The software version is displayed at the top of the window:
Figure 14 Software version For software updates, check NOVUS website periodically.
NOVUS AUTOMATION
9/21
5.2.2 PANEL WITH CONFIGURATION FUNCTIONS These are the tabs with configuration
functions:
Figure 15 Configuration functions · Temp 1: Displays information about the
sensor status and the sensor notification panel. · SensorID P1: Allows you to
enable or disable sensors and sensor identification settings. For more
information, see HOW TO CONFIGURE THE
P1 SENSORID INTERFACE section. · Basic Settings: Allows you to configure the
address and put the panel in test mode. For more information, see HOW TO
PERFORM A BASIC
CONFIGURATION section. · Antenna Settings: Allows you to enable or disable the
antenna. For more information, see HOW TO CONFIGURE THE ANTENNAS section.
5.2.3 DISPLAYING TEMPERATURE DATA FOR THE SENSOR This section displays the
temperature data from the sensor used:
Figure 16 Temperature display In addition to the temperature value, the
software can also display the following messages: · When the warning “Reading
Failed” is displayed: There has been a failure to read the temperature. · When
the warning “Not configured” is displayed: The sensor ID has not been set. ·
When the warning “Disabled” is displayed: This sensor has been disabled. ·
When “—” is displayed: Software still in boot process. The software has not
received any temperature readings. · When the warning “ANT Disabled” is
displayed: The antenna to read the sensor has been disabled.
5.2.4 SELECTION OF THE RELATED USB COMMUNICATION PORT You can select which USB
port to use:
Figure 17 Selecting the USB port You can find the computer’s COM port under
“Control Panel” “Device Manager” “Silicon Labs CP210x USB to UART Bridge
Port”. · Open/Close button: Allows you to start/stop the connection with the
reader. For more information about the USB interface, see USB INTERFACE
section.
5.2.5 REAL-TIME DATA COLLECTION FUNCTION By clicking on the Open log folder
button, you can view the folder created for saving information about the data
collection:
Figure 18 Open log folder button
The “T_Log” folder will be created when you first use the software (at reading
temperature). By double-clicking Open log folder and choosing the “3.0” folder
within it, you can find the log file of the reading. Each reading will
generate a document, as shown in the figure below. The file will be named
after the reading has been stopped.
Figure 19 Files generated by the software File description: · Text file “ExportParameter(Time)”: Log file for reader parameters at the beginning of the reading.
NOVUS AUTOMATION
10/21
· CSV file “Log_(Time)”: Real-time log file for reading temperatures, antenna
signal, etc.
5.2.6 FIRMWARE VERSION This section displays the firmware version of the
device:
Field description: · RF: Refers to the Radio Module. · uC: Refers to the Control Module.
Figure 20 Firmware version
When installing a new control module firmware, you should test its
compatibility with the Telik Gardo software version. This will prevent errors
in the device.
Check NOVUS website periodically for firmware updates.
5.2.7 START/STOP SENSOR READING This button is used to start or stop the sensor reading:
Figure 21 Start/Stop button
5.3 HOW TO CONFIGURE THE P1 SENSORID INTERFACE
This section displays instructions on how to assign an ID for the sensor read
by Telik Gardo Reader. The sensor settings will be visible when the read
function is enabled to request signals from Telik Gardo Reader. To do this,
you must click on the SensorID P1 tab of the configuration software, as shown
in the figure below:
Figure 22 Configuring the sensor ID
NOVUS AUTOMATION
11/21
Then you should follow the steps below: 1. Select the sensors to be read by the device:
2. Define an ID and a description for the sensor:
Figure 23 Selecting the sensors
Figure 24 Defining an ID Field description: · Desc: Allows you to enter a
description for the sensor. You can use letters and numbers (Example: X33A). ·
Sensor ID: Allows you to enter an ID for the sensor. You can enter numbers and
upper-case and lower-case letters.
Advanced Function: After defining the sensor ID, you can double-click on the
text in the “Sensor ID” field. This allows you to copy the information from
the Sensor ID column to the Desc column.
3. Set the antenna port for the sensor (ANT 1 ~ ANT 4):
Figure 25 Defining an antenna You must configure the antenna according to
the field tests previously performed. Each sensor can have a maximum of 2
antennas. 4. Use the Read and Write buttons to set the parameters. The Read
button allows you to get the current configuration parameters. The Write
button allows you to overwrite and update the Telik Gardo Reader settings with
the defined parameters. 5. You can use the Read All and Write All buttons
(located in the upper right corner of this tab) to get or set all the
configuration parameters. 6. You can use the Enable All Sensors and Disable
All Sensors buttons to enable or disable all sensors at once. 7. You can use
the Load and Export buttons to load or export the function list. 8. You can
use the Read All and Write All buttons to collect or configure all sensor
information at once.
NOVUS AUTOMATION
12/21
5.4 HOW TO PERFORM A BASIC CONFIGURATION
This section displays information on how to configure a slave for the Modbus
communication protocol (Telik Gardo Reader for master device). To do this, you
must click on the Basic Settings tab, as shown in the figure below:
Figure 26 Basic Settings On this screen, you must configure the parameters
of the RS485 interface:
Figure 27 RS485 interface parameters You must choose the desired settings
from the options for each parameter. The Read button allows you to overwrite
the data. The Write button allows you to get the current parameters. Parameter
description: · Slave address: Allows you to define the slave address to be
used. · Baud Rate: Allows you to define the Baud Rate to be used. · Parity:
Allows you to define the parity, data length and Stop Bits. For more
information about the RS485 interface, see RS485 INTERFACE section.
5.5 HOW TO CONFIGURE THE ANTENNAS
This section presents instructions on how to enable or disable the antenna
ports of Telik Gardo Reader. To do this, you must click on the Antenna
Settings tab, as shown in the figure below:
Figure 28 Antenna configuration
NOVUS AUTOMATION
13/21
Then you should follow the steps below: 1. Enable the desired antenna (ANT 1 ~
ANT 4):
Figure 29 Enabling the antennas The ANT 1 ~ ANT 4 options do not appear
until the COM port is enabled. 2. Use the Read and Write buttons to get or set
all the configuration parameters.
5.6 HOW TO USE THE TOOLBAR
5.6.1 TOOLBAR This is the toolbar:
Icon description:
Figure 30 Toolbar
·
: Allows you to download and upgrade the firmware of the module and the base board.
·
: Allows you to open the control panel.
·
: Allows you to change the language settings.
·
: Displays information about the software version.
NOVUS AUTOMATION
14/21
5.6.2 RF CTRL INTERFACE INSTRUCTIONS
You must click on the
icon to open the RF CTRL interface, as shown in the figure below:
Figure 31 Opening the RF CTRL interface 5.6.3 FIRMWARE DOWNLOAD INTERFACE INSTRUCTIONS
You must click the
icon to open the interface for downloading the module or base board firmware, as shown in the figure below:
Figure 32 Firmware update Then you should follow the steps below: 1. Select
the firmware to upgrade and click Select FW File. This will allow you to
choose the destination folder:
Figure 33 Destination folder Files description: · RF Firmware:
TGModulo_V4.XX…. bin file to update the RF Module firmware. · Motherboard
firmware: TGPlacaMae_FW_P8… bin file for updating the motherboard firmware.
NOVUS AUTOMATION
15/21
2. The update should proceed after choosing the firmware file. The loading
bar indicates the progress of the process:
Figure 34 Firmware update 3. After the update has been completed, Windows
will display the following pop-up:
Figure 35 Process completed During the upgrade process, do not disconnect
the device’s power supply or USB connection cables. Otherwise, there may be a
failure during the upgrade, as well as irreversible damage. If something
happens, contact Technical Support.
NOVUS AUTOMATION
16/21
6 MODBUS-RTU PROTOCOL
Telik Gardo Reader is compatible with the Modbus-RTU protocol, a data
communication protocol used to connect the device to supervisory control and
data acquisition systems (SCADA).
6.1 COMMANDS
READ HOLDING REGISTERS 0x03: This command can be used to read the value of
one or up to a maximum of 125 consecutive registers, according to the Register
Table.
6.2 REGISTERS TABLE
ADDRESS 1300 1301 1302 1303 1304 1305 1306 1307 1308 1309 1310 1311 1312 1313 1314 1315 1316 1317 1318 1319 1320 1321 1322 1323 1324 1325 1326 1327 1328 1329 1330 1331 1332 1333 1334 1335
DESCRIPTION Temperature Sensor #1 Temperature Sensor #2 Temperature Sensor #3 Temperature Sensor #4 Temperature Sensor #5 Temperature Sensor #6 Temperature Sensor #7 Temperature Sensor #8 Temperature Sensor #9 Temperature Sensor #10 Temperature Sensor #11 Temperature Sensor #12 Temperature Sensor #13 Temperature Sensor #14 Temperature Sensor #15 Temperature Sensor #16 Temperature Sensor #17 Temperature Sensor #18 Temperature Sensor #19 Temperature Sensor #20 Temperature Sensor #21 Temperature Sensor #22 Temperature Sensor #23 Temperature Sensor #24 Temperature Sensor #25 Temperature Sensor #26 Temperature Sensor #27 Temperature Sensor #28 Temperature Sensor #29 Temperature Sensor #30 Temperature Sensor #31 Temperature Sensor #32 Temperature Sensor #33 Temperature Sensor #34 Temperature Sensor #35 Temperature Sensor #36
UNIT 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C
RANGE -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500
NOVUS AUTOMATION
17/21
ADDRESS 1336 1337 1338 1339 1340 1341 1342 1343 1344 1345 1346 1347
DESCRIPTION Temperature Sensor #37 Temperature Sensor #38 Temperature Sensor
39 Temperature Sensor #40 Temperature Sensor #41 Temperature Sensor #42
Temperature Sensor #43 Temperature Sensor #44 Temperature Sensor #45
Temperature Sensor #46 Temperature Sensor #47 Temperature Sensor #48
Table 3 Registers table
UNIT 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C 0.1 °C
6.2.1 RELATIVE HUMIDITY INFORMATION (OPTIONAL)
ADDRESS 1491 1492 1493 1494 1495 1496 1497 1498 1499
DESCRIPTION Room temperature 1 Humidity 1 Dew point 1 Room temperature 2
Humidity 2 Dew point 2 Room temperature 3 Humidity 3 Dew point 3
Table 4 Relative Humidity table
UNIT 0.1 °C 0.1 % 0.1 °C 0.1 °C 0.1 % 0.1 °C 0.1 °C 0.1 % 0.1 °C
RANGE -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500
-400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500 -400 ~ 1500
RANGE -400 ~ 1500
0 ~ 999 -400 ~ 1500 -400 ~ 1500
0 ~ 999 -400 ~ 1500 -400 ~ 1500
0 ~ 999 -400 ~ 1500
NOVUS AUTOMATION
18/21
7 TECHNICAL SPECIFICATIONS
FEATURES Operating temperature
Frequency range
-20 to 70 °C (-4 to 158 °F) 920 MHZ 925 MHZ
TELIK GARDO READER
Antenna ports
4 ports
Range / Receive range Dimensions
Communication interfaces
Power supply Software
Certifications
Up to 2 meters, depending on the position of the antenna and sensor. 80 x 45 x
118 mm USB 2.0 Interface RS485 Communication Interface with Modbus-RTU
protocol 100 ~ 240 V (±10 %) Telik Gardo Software Anatel (01031-22-11205),
FCC, CE, UKCA
Table 5 Device technical specifications
FEATURES Connector Dimensions
Installation type
Operating temperature Polarization Antenna gain
Protection Index
SMA Male 46.5 x 21.1 x 22.2 mm
TELIK GARDO ANTENNA
Assemble with magnet or screw.
-20 to 85 °C Circular 3 dbi IP54
Table 6 Antenna technical specifications
FEATURES Accuracy Dimensions
Installation type
Reading range Measurement range
Protection index Maximum monitored line voltage
+/- 2 °C 69 x 27 x 23 mm
TELIK GARDO SENSOR
Screw or clamp
2-3 meters -20 ~ 125 °C IP30 40 kV
Table 7 Sensor technical specifications
7.1 CERTIFICATIONS
ANATEL This device is homologated by ANATEL, according to the regulated
procedures for conformity assessment of telecommunications products, and meets
the technical requirements applied. This equipment is not subject to the
protection from harmful interference and may not cause interference with duly
authorized systems. For more information, see ANATEL website:
www.anatel.gov.br.
FCC
FCC ID: 2A3F5PQS-RD-01
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
RF Exposure: To meet the FCC RF exposure requirements for mobile and base
station transmission, a separation distance of 6.5 cm or more must be
maintained between the antenna of this device and people during operation. To
ensure compliance, it is not recommended to operate at a closer distance. The
antennas used for this transmitter must not coincide or operate with any other
antenna or transmitter.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOVUS AUTOMATION
19/21
CE Mark / UKCA
This is a Class A product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures.
NOVUS AUTOMATION
20/21
8 WARRANTY
Warranty conditions are available on our website
www.NOVUSautomation.com/warranty.
NOVUS AUTOMATION
21/21
References
- NOVUS Automation Inc. - Controllers, Thermostats, Data Loggers, Solid State Relays, Sensors, Transmitters, SCADA, Data Acquisition and Temperature Controllers
- NOVUS Automation Inc. - Controllers, Thermostats, Data Loggers, Solid State Relays, Sensors, Transmitters, SCADA, Data Acquisition and Temperature Controllers
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>