NOVUS RHT-WM and Transmitter User Guide
- May 15, 2024
- Novus
Table of Contents
NOVUS RHT-WM and Transmitter
Product Information
Specifications:
- Product: RHT-WM and RHT-DM Transmitter
- Brand: NOVUS AUTOMATION
- Model: RHT-WM and RHT-DM
Product Usage Instructions
Safety Alerts
Refer to the safety alerts section in the manual before proceeding with the
installation or usage of the transmitter.
Presentation
Understand the components and features of the RHT-WM and RHT-DM transmitters
before installation.
Installation
Mechanical Installation
Follow the mechanical installation guide provided in the manual to mount the
transmitter securely.
Electrical Installation
Proceed with the electrical installation by following these steps:
Installation Recommendations
Adhere to the installation recommendations to ensure proper functioning of the
transmitter.
Sensor Cautions
Take caution while handling the sensor to prevent damage.
Sensor Replacement
Refer to the manual for guidance on sensor replacement when needed.
Configuration
Software and App
Configure the transmitter using the software and app provided:
Signow Software
Utilize the Signow software for initial setup and configuration.
Signow: Dew Point Retransmitting
Follow instructions for dew point retransmitting using Signow.
TXConfig Software
Use the TXConfig software for specific configurations.
TXConfig: Dew Point Retransmitting
Configure dew point retransmitting with TXConfig as per guidelines.
Signow App
Download and use the Signow app for convenient monitoring and adjustments.
Smartphone Connections
Establish connections with smartphones as detailed in the manual for remote
access.
FAQ:
Q: How often should the sensor be replaced?
A: Sensor replacement frequency depends on usage and environmental
conditions. Refer to the manual for specific guidelines.
Q: Can I configure the transmitter without using the software?
A: While software provides advanced configuration options, basic setup
can be done directly on the transmitter following manual instructions.
SAFETY ALERTS
The symbols below are used in the device and throughout this manual to draw the user’s attention to essential information related to device safety and use.
| |
---|---|---
CAUTION
Read the manual fully before installing and operating the device.
| CAUTION OR HAZARD
Risk of electric shock.
| ATTENTION
Material sensitive to static charge. Check precautions before handling.
All safety recommendations appearing in this manual must be followed to ensure
personal safety and prevent damage to the instrument or system.
If the instrument is used in a manner other than that specified in this
manual, the device’s safety protections may not be effective.
PRESENTATION
RHT-WM and RHT-DM transmitters feature highly accurate and stable sensors for
measuring relative humidity and temperature. The measured values are converted
into 4 to 20 mA output signals linearly related to their readings.
The microprocessor-based circuit can be configured with the TxConfig-USB
communication interface and SigNow and TxConfig software and SigNow app. It is
possible to configure the measurement and humidity transmission between
Relative Humidity and Dew Point.
INSTALLATION
MECHANICAL INSTALLATION
The RHT-DM (Duct Mount) model must be attached with a flange. The flange is
attached to the duct wall. After this, the transmitter probe must be inserted
into the flange center hole and then fixed. Figure 1 shows the dimensions and
drilling of the polyamide 6.6 flange:
The probe is made of stainless steel, with the following lengths: 150 mm, 250 mm, or 400 mm.
The RHT-WM (Wall Mount) model must be attached to the wall. By removing the transmitter cover, you can access the two fixing holes and the connector, as shown in Figure 3. To ensure the specified accuracy and protection degree, you must mount the transmitter with the sensor capsule facing down.
ELECTRICAL INSTALLATION
The transmitter has a 4-20 mA current output.
Variables can be monitored together or separately. Combinations of mobile
jumpers J4 and J5 inside the transmitter housing define how variables will be
used. The jumpers also define the transmitter terminals with available output
signals.
Table 1 – OUT1 and OUT2 outputs configuration
Jumper J5 | Jumper J4 | OUT1 | OUT2 |
---|---|---|---|
Position A | Position A | Temperature | Humidity |
Position A | Position B | Temperature | Off |
Position B | Position A | Humidity | Off |
Position B | Position B | Humidity | Temperature |
Figures below shows the required electrical connections.
In the figures above, LOAD represents the measuring instrument of the output
signal (indicator, controller, register, etc.).
The connection wires go inside the transmitter trough to the cable gland
mounted in the transmitter housing.
INSTALLATION RECOMMENDATIONS
- Electronic and analog signal conductors should run through the plant separately from the output and supply conductors. If possible, in grounded conduits.
- The power supply for electronic instruments must come from a network suitable for instrumentation.
- In controlling and monitoring applications, you must consider what can happen when any part of the system fails.
- It is recommended to use RC filters (47 Ω and 100 nF, serial) in inductor charges (contactors, solenoids, etc.).
SENSOR CAUTIONS
The humidity sensor calibration may change in case it is exposed to
contaminating vapors or to high humidity and temperature conditions for
extended periods. To speed up the calibration restoration, proceed as
described below:
- Remove the sensor from the capsule.
- Wash it with deionized water in case there are solid particles on it.
- For 24 hours, place it within an 80 °C (± 10 °C) oven.
- For 48 hours, place it in a place with temperature between 20 and 30 °C (68 and 86 °F) and humidity over 75 % RH.
- Place the sensor back in the capsule.
SENSOR REPLACEMENT
In case of damage, the humidity and temperature sensor may need to be
replaced. To perform this procedure, follow the steps below:
Step 1: Disconnect the transmitter from the power supply. Locate the
sensor protective tip.
This example shows the sensor replacement of an RHT-DM transmitter. In it, the
sensor is located at the end of the probe.
Step 2: Remove the tip by turning it counterclockwise.
Step 3: Without the tip, the sensor will be exposed. Remove it by pulling it forward to disconnect it.
Step 4: Connect the new sensor to the probe tip connector using clean antistatic gloves or other measures to avoid static discharges. Avoid unnecessary handling.
Step 5: Place the protection tip again and turn it clockwise to secure it to the device.
CONFIGURATION
If the default configuration or the ordered configuration satisfies the application, then no further configuration is necessary, and the transmitter is ready to be used. When it is necessary to change the configuration of the equipment, you should use SigNow software, TxConfig software, or SigNow app.
To configure the equipment through any of the software, you must connect the TxConfig-USB Configuration Interface (purchased from the manufacturer or its authorized representatives) to the USB port of the computer used and run the selected software, as shown in Figure 8:
To configure the device via the SigNow app, you need to use an OTG cable with
the TxConfig-USB Configuration Interface and proceed with the recognition
process (see SMARTPHONE CONNECTIONS chapter).
On NOVUS website, you can download the configuration software for free. To
install it, simply run the file SigNowSetup.exe or the file TxConfigSetup.exe
and follow the instructions in the installer.
The SigNow setup application can be downloaded for free from Google Play
Store.
SOFTWARE AND APP
-
SIGNOW SOFTWARE
When running the SigNow software and connecting to the device, the following screen will appear:
The bottom part of the screen displays information about the model, serial number, and firmware version.
The configuration screen is divided into 3 sections: Humidity, Temperature and Diagnostic.
In the Humidity (see above) screen, you can configure the device by setting values and information for the following parameters: -
Output type: Allows you to define the equipment output type.
-
Humidity measurement: Allows you to define the humidity measurement. The Relative Humidity option is configured by default.
-
Reverse output polarity: Allows you to reverse the output polarity.
-
Lower limit: Allows you to define the minimum desired temperature for the output type configured.
-
Upper limit: Allows you to define the maximum desired temperature for the output type configured.
-
Output status (Sensor failure): Allows you to establish the transmitter output behavior (upscale or down-scale) in the presence of a sensor fail.
When selecting the Minimum option, the output current is < 4 mA (down-scale). Typically used for refrigeration.
When selecting the Maximum option, the output current is > mA (up-scale). Typically used in heating systems. -
Zero correction: Allows you to make small sensor corrections.
In the SigNow manual, available on NOVUS website, you can get more specific information about the buttons and the process of diagnostics and firmware update. -
SIGNOW: DEW POINT RETRANSMISTTING
To use RHT and transmit dew point instead of relative humidity, the Dew Point option should be selected in the Humidity Measurement parameter. At this point, the scale values will be converted to the dew point unit, that is, degrees (Celsius or Fahrenheit, as selected).
You must proceed with the rest of the configuration and send it to the equipment via the Send. -
TXCONFIG SOFWARE
When running the TxConfig software and connecting to the device, the following screen will appear:
The fields in the screen mean: -
Measuring Range: Allows you to define the transmitter humidity and temperature measurement ranges, indicating a Lower Limit value and an Upper Limit value.
The defined range cannot exceed the Sensor Measuring shown in this same field, and cannot establish a range with a span less than the Minimum Range indicated below in this same field.
When the Lower Limit is set to a value higher than the Upper Limit, the output current has a decreasing behavior (20 ~ 4 mA). -
Sensor Failure: Allows you to define the transmitter output behavior in the presence of a sensor fail.
When Minimum is selected, the output assumes its minimum value (4 mA) (down- scale).
When Maximum is selected, it assumes its maximum value (20 mA) (up-scale). -
Zero Correction: Allows you to make small sensor corrections.
-
Device Information: This field contains data that identifies the transmitter and is important in any queries to the manufacturer.
-
Read Device: When selected, allows you to read the configuration present on the connected transmitter.
-
Apply: When pressed, allows you to send the configuration to the connected transmitter. Note: The factory default configuration is (unless otherwise specified or ordered):
* Measuring ranges: 0 to 100 °C and 0 to 100 % RH.
* Correction zero: 0 °C.
* Upscale when sensor fails.
It is important to notice that the transmitter accuracy is always based on the
total span of the used sensor, even if a narrower range is configured.
Example:
The humidity sensor has a maximum range of 0 to 100 % RH and an accuracy of 3
% at 25 ° C, as shown in Figure 17. We can have an error of up to 3 % RH in
any adopted range.
This error is even in a wide range as the maximum (0 to 100 % RH) or in a
narrower range, such as 20 to 80 % RH.
A serial port configuration error may occur when other software uses the same
serial port. Before using it, you must terminate all software that uses the
serial port specified for TxConfig.
-
TXCONFIG: DEW POINT RETRANSMITTING
To use the RHT and transmit the dew point instead of relative humidity, you must follow the following steps:- Connect the device to the TxConfig-USB Configuration Interface and run the software.
- The software will recognize the RHT model, read its configuration and make it available to the user.
- In the Options menu, enter Humidity Reading Type and select the Dew Point option. At this point, the values of the scales will be converted to the dew point unit, i.e., degrees (Celsius or Fahrenheit, as selected).
- Proceed with the configuration and send it to the device via the Apply button.
If the Humidity Reading Type option does not appear even after the RHT transmitter is correctly detected, the TxConfig software version is probably old and does not support this feature. In this case, download and update the latest version
-
SIGNOW APP
When using an OTG cable and the TxConfig-USB Configuration Interface to connect the equipment to your smartphone and run the SigNow app (see SMARTPHONE CONNECTIONS chapter), you must first enable the use of TxConfig- USB.
The interface will act as an intermediary for the connection:
This screen shows information about the equipment, such as name, serial
number, and firmware version.
When you open the Config section, you can configure the parameters displayed
in the SIGNOW SOFTWARE section.
In the SigNow manual, available on NOVUS website, you can find more
information about the buttons and the diagnostic process.
SMARTPHONE CONNECTIONS
Smartphones with On the Go (OTG) technology can be directly connected to the device via the USB input. Using the TxConfig-USB Configuration Interface, it is possible to recognize and configure RHT by running the SigNow app.
To do this, as shown in Figure 16, you need to observe how to connect the OTG cable to the equipment:
If you position the cable end incorrectly, it is possible that the device will not be recognized by the application.
SPECIFICATIONS
Table 2 – Technical specifications
FEATURES | RHT-DM / RHT-WM |
---|
Humidity measurement
| Total accuracy : See Figure 17.
Response time (1/e (63 %)) : 8 seconds @ 25 °C (is slow moving air 1 m/s).
Measurement range : Configurable between 0 and 100 % RH or -100 and 103 °C (-148 to 217.4 °F) for dew point.
Sensor temperature measurement
| Total accuracy : See Figure 17.
Response time (1/e (63 %)) : Up to 30 s (is slow moving air 1 m/s).
Measurement range: · DM Model: Configurable between -40 and 120 °C (-40 and 248 °F).
· WM Model: Configurable between -10 and 60 °C (14 and 140 °F).
Transmitter operating temperature| Operating temperature: -10 to 65 °C (14 to 149 °F), 0 to 95 % RH
Storage temperature: -20 to 80 °C (-4 to 176 °F)
Power supply| 12 Vdc to 30 Vdc
Sensor reading range| < 1.5 seconds
Outputs| 4-20 mA or 20-4 mA current, 2-wire loop power supply.
Output Load (RL)| RL (Ohms max.) = (Vdc – 12) / 0.02 let: Vdc = Power
supply in Volts.
OUT1 output resolution| 0.006 mA (4-20 mA)
OUT2 output resolution| 0.022 mA (4-20 mA)
Isolation between loops| 4-20 mA outputs are isolated from each other.
Provides protection against power supply polarity inversion|
Yes
Protection
| Electronic circuit case: IP65.
Sensor capsule : IP40.
Cable entrance| Cord grip PG7.
Operating limits| Sensor and Probe (RHT-DM) : See Figure 17.
IMPORTANT
The transmitter sensor may be damaged or lose calibration if it is exposed to
aggressive atmospheres with high concentrations as Chloride Acid,
Nitride Acid, Sulfuric Acid, and Ammonia. Acetone, Ethanol, and Propylene
Glycol may cause reversible measurement errors.
MEASURES ACCURACY AND SENSOR OPERATING LIMITS
CERTIFICATIONS
CE Mark
This is a Class A product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures.
WARRANTY
Warranty conditions are available on our web site
www.novusautomation.com/warranty.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>