■ Features:

  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • 1500VAC I/O isolation
  • Forced air cooling by built-in DC Fan
  • 100% full load burn-in test
  • 24V and 48V input voltage design refer to LVD
  • 2 years warranty

SPECIFICATION

MODEL SD-350B SD-350C
OUTPUT DC VOLTAGE 5V
RATED CURRENT 57A 27.5A
CURRENT RANGE 0 – 5M 0 – 27.5A
14.6A 0 – 7.3A
RATED POWER 285W 330W
RIPPLE & NOISE (max.) Note/ 100mVp-p 120mVp-p
120mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 4.5 – 5.5VDC 11 – 16VDC
5.5VDC 11 – 16VDC 23 – 30VDC
VOLTAGE TOLERANCE Not4.3 ±2.0% 31.%

±1.0%
LINE REGULATION| ±0.5%| ±0.3%| ±0.2%| ±0.2%| 31.%| ±0.3%| ±0.2%| ±0 2%
LOAD REGULATION| ±1.0%| 31.%| 31.%| ±1.0%| ±1.0%| ±1.0%| 31.%| ±1.0%
SETUP, RISE TIME| 300ms, 50ms at full load
INPUT| VOLTAGE RANGE| 8:19 – 36VDC C:36 – 72VDC D:72 -144VDC
EFFICIENCY (Typ.)| 74%| 80%| 80%| 84%| 76%| 81%| 81%| 82%
DC CURRENT (Typ.)| 14.4A/24V| 16A/24V| 17.6A/24V| 17.6A/24V| 7.6A/48V| 8.8A/48V| 9.0A148V| 9.0A148V
INRUSH CURRENT (Typ.)| C:45N48VDC D:45A/96VDC
PROTECTION| OVERLOAD| 105 – 135% rated output power
Protection type : Shut down olp voltage, re-power on to recover
OVER VOLTAGE| 5.75 – 6.75V| 1 16.8 – 20V| 1 31.5 – 37.5V| 1 53 – 65V 1 5.75 – 6.7W| 1 16.8 – 20V| 1 31.5 – 37.5V| 1 53 – 65V
Protection type : Shut down o/p voltage. re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
EWIROMIENI| WORKING TEMP.| -20 – +60°C (Refer to ‘Derating Curve)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/t (0 – 50°C)
VIBRATION| 10 – 500Hz, 2G 10min./1cycle, 60min. each along X. V, Z axes
SAFETY & EMC
(Note 4)| SAFETY STANDARDS| EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-01P:1.5KVAC 1/P-Fa2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-0/P, NP-FG, 0/P-FG:100M Ohms / 500VDC 125°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EWEN61000-4-2,3,4,6,8, 8S EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 1705.6K hrs min. Telcordia SR-332 (Bellcore) ; 263.9K hrs min. MIL-HDBK-217F (25t )
DIMENSION| 215’115’50mm (L’W’H)
PACKING| 1.1Kg; 12pcs/14.4Kg10.9CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 2OMHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  5. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft)
    Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

SPECIFICATION

MODEL SD-350D
OUTPUT DC VOLTAGE
RATED CURRENT 60A
CURRENT RANGE 0 – 60A
RATED POWER 300W
RIPPLE & NOISE (max.) Note/ 100mVp-p
VOLTAGE ADJ. RANGE 4.5 – 5.5VDC
VOLTAGE TOLERANCE Note.3 ±2.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±1.0%
SETUP, RISE TIME 300ms, 50ms at full load
INPUT VOLTAGE RANGE
EFFICIENCY (Typ.) 78%
DC CURRENT (Typ.) 6A196V
INRUSH CURRENT (Typ.) C:45N4BVDC D:45A/96VDC
PROTECTION OVERLOAD

Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 5.75 – 6.75V| 1 16.8 – 20V| 31.5 – 37.5V| 153 – 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
ENVIROMEK| WORKING TEMP.| -20 – +60°C (Refer to ‘Derating Curve’)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/°C (0 – 50°C)
VIBRATION| 10 – 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC (Note 4)| SAFETY STANDARDS| IECIBS EN/EN 62368-1, EAC TP TC 004 approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-0/P:1.5KVAC 1/P-Fa2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, 0/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55022 (CISPR22) Class B, EAC TP TC 020
EMC IMMUNITY| Compliance to BS ENEN61000-4-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 1705.6K hrs min. Tetcordia SR-332 (Bellcore) ; 263.9K hrs min. MIL-HDBK-217F (25-C )
DIMENSION| 215’115’50mm (L’W’H)
PACKING| 1.1Kg; 12pcs/14.4Kg/0.9CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25°C of ambient temperature.
  2. Ripple & noise are measured at 20OMHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  5. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft)
    Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL SD 350 Series 350W Single Output DC DC Converter - Mechanical
Specification

Terminal Pin No. Assignment :

Pin No. Assignment Pin No. Assignment
1 DC INPUT V+ 4,5,6 DC OUTPUT V-
2 DC INPUT V- 7,8,9 DC OUTPUT V+
3 FG – ****

Block Diagram

MEAN WELL SD 350 Series 350W Single Output DC DC Converter -
Diagram

Derating Curve

MEAN WELL SD 350 Series 350W Single Output DC DC Converter - Derating Curve
1

Static Characteristics

MEAN WELL SD 350 Series 350W Single Output DC DC Converter - Derating Curve
2

File Name:SD-350-SPEC 2022-09-20
Downloaded from Arrow.com.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals