BEGA 24173 Ceiling and Wall Luminaire Instruction Manual

June 13, 2024
BEGA

24173 Ceiling and Wall Luminaire
Instruction Manual

Technical amendments reserved
Ceiling and wall luminaire

24173 Ceiling and Wall Luminaire

Instructions for use

Application

Unshielded ceiling and wall luminaire with high protection class.
A luminaire made of aluminium alloy and crystal glass.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure ® coating technology
Crystal glass, white inside 2 mounting holes ø 4.5 mm Distance apart 236 mm 2 screw cable glands with strain relief for through-wiring power connecting cable ø 7–12 mm 1 screw cable gland closed at the factory with a dummy plug Connection terminal 2.5@ Earth conductor connection LED power supply unit 220-240 V x 0/50-60 Hz DC 176-280 V BEGA Thermal Switch ®  Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Ballproof – The testing of ball impact safety
was carried out exclusively with handballs in accordance with DIN 18032-3: 2018-11.
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK10
Protection against mechanical impacts < 20 joule
– Safety mark
– Conformity mark
Weight: 2.6 kg
This product contains light sources of energy efficiency class(es) C, D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

Module connected wattage 12.9 W
Luminaire connected wattage 15 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 30 °C

24 173 K3

Module designation LED-0985/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 2155 lm
Luminaire luminous flux 1158 lm
Luminaire luminous efficiency 77,2 lm / W

24 173 K4

Module designation LED-0985/840
Colour temperature 4000 K
Colour rendering index CRI > 80
Module luminous flux 2265 lm
Luminaire luminous flux 1217 lm
Luminaire luminous efficiency 81,1 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo hexagon socket head screw (wrench size 3 mm) through the opening in the luminaire housing up to the stop and lift luminaire top.
Disconnect the earth conductor connection from the plug connection.
Disconnect plug-connection of the LED connecting cable.
Lead the mains supply cable through the screw cable gland into the luminaire back housing.
The installed black gasket insert is intended for cables ø < 10 mm.
For cables ø 10-12 mm the enclosed grey gasket insert must be used.
In case of through-wiring replace the factory installed dummy plug with the enclosed corresponding gasket insert.
At the same time, use the enclosed synthetic cone-thrust collar between gasket insert and thrust screw (wrench size 22 mm) (see sketch).

Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Tighten screw cable gland.
Make the earth conductor connection and the electrical connection.\
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
Connect the LED connection cable by means of a plug connector.
Make earth conductor connection between luminaire top and luminaire base.
Push plug into coupler as far as it will go.

In order to ensure the tightness of the luminaire, the grub screw for fixing the luminaire upper part must not lie in the marked area.
Make sure that gasket is positioned correctly.
Tighten grub screw firmly.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass 11 003 518
LED power supply unit DEV-0150/350
LED module 3000 K LED-0985/830
LED module 4000 K LED-0985/840
Gasket glass 83 001 907
Gasket housing 83 002 167 B1

BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60
· 58689 Menden ·
info@bega.com ·
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals