Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated and does not require connection to an Earth circuit.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting.
Ensure other persons cannot restore the electrical supply without your
knowledge.
If replacing an existing fitting, make a careful note of the connections.
This product complies with IEE Building Regulations part B and is suitable for
use in 30, 60 or 90 minute fire rated ceilings.
This product is suitable for covering with insulation 300mm.
This luminaire is suitable for use in ambient temperatures of -10°C to +40°C.
This system contains non-replaceable parts and cannot be serviced. If damage
occurs the part should be scrapped.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position
cables and junction boxes (not supplied) away from areas where they may be at
risk from being cut, trapped or damaged.
The mains supply cable must have a minimum cross section area of 1.0 mm².
Cables must be protected using suitable conduit or plastic trunking.
When more than one downlight is installed, the minimum distance between units
is 500mm. the unit must be located a minimum distance of 50mm from a joist.
This product must be mounted out of arms reach.
This product is suitable for use in zone 2 and outside zones of a bathroom.
Please see diagram.
If this unit is being fitted in Zone 1 a room containing a bath or shower, a
30mA RCD must be used – in accordance with IEE regulations.
Installation
Existing fittings must be completely removed before installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires.
The ceiling surface must be flat and smooth to ensure a good fit.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP
rating of the product.
- Cut a mounting hole 70mm diameter in the ceiling taking care not to foul any pipes, mains cables or joists beneath the surface (Ref. Fig.1). It is always recommended to cut the hole slightly smaller than the size specified, and then file the hole until the recessed unit fits snugly. Ensure a minimum ceiling void depth of 48mm is available.
- Open the terminal block cover, Connect the mains supply cable into the terminals (Ref. Fig. 2).
- Ref. Fig. 3. Choose your preferred wattage or colour before installing by wattage switch or CCT switch on the back of the product. Note: Befeore you change the wattage or colour, please turn off the power switch for safety. The wattage is changeable between 4/6/8W using the wattage switch on the drive before installation. The colour is changeable between 2700/3000/4000/6000K using the CCT switch on the drive before installation.
- Push the spring clips upwards and fit into the ceiling hole, then push the unit up until firmly in position, ensuring that no cables are trapped. (Ref. Fig. 4).
- Ensure that the product is sitting properly in the hole.
- Switch on. Your light is now ready for use.
Wiring
Having correctly identified the wiring from your existing light fitting, pull
the mains wire through the hole and connect to the quick fit connection block
in the following way. Check
that…
You have correctly identified the wires.
The connections are tight.
No loose strands have been left out of the connection block.
Terminations:
Live supply to L = ( Brown or Red )
Earth to ****= ( Green / Yellow )
Neutral to N = ( Blue or Black )
The terminal block allows for Loop-in / Loop-out connection.
Technical data
Supply Voltage: | 220-240 V~, 50 Hz |
---|---|
Bulb Type: | 4/6/8W LED SMD 4CCT, 2700/3000/4000/6000K |
This product contains a light source of energy efficiency class E.
| Non-replaceable light source
| Non-replaceable control gear
| Conformity with all relevant UKCA Directive requirements.
| Conformity with all relevant EC Directive requirements.
| The power supply is Double Insulated and does not require connection to
an Earth circuit.
****| Waste electrical products should not be disposed of with household
waste. Please recycle where facilities exist.
Check with your Local Authority or local store for recycling advice.
| This product is suitable for dimming.
| This product is fire rated to 30, 60, 90 minutes.
| This product is rated at IP65 (Below the ceiling), IP20 (Recessed parts).
Optional Colour Bezels
There are three optional colour bezels – 90377 (Satin Nickel), 90378 (Chrome)
and 92513 (Matt black). Rotate the fixed bezel one quarter turn anticlockwise
and pull it away from the luminaire. Select a new bezel and rotate it one
quarter turn clockwise back onto the front of the luminaire.
Do not remove the rubber seal from the rear of the luminaire outer rim. Ensure
that it is secure and correctly positioned to maintain the IP65 rating.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
For further information, please visit https://www.lighting-info.co.uk/102630
V3 16/12/2022
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg
www.saxbylighting.com