Danfoss ECtemp Next Plus Electronic Intelligent Timer Thermostat Installation Guide
- June 12, 2024
- Danfoss
Table of Contents
Danfoss ECtemp Next Plus Electronic Intelligent Timer Thermostat
Introduction
The Danfoss ECtemp Next Plus is an electronic programmable timer thermostat used for controlling electrical floor heating elements. The thermostat is designed for fixed installation only and can be used for both direct heating of the entire room and for comfort heating of the floor. More information on this product can also be found at: electricheating.danfoss.com
Technical Specifications
Operation voltage | 85-250V~, 50/60 Hz |
---|---|
Standby power consumption | 0,4 W |
Relay: Resistive load Inductive load | **** |
Max. 16 A / 3680 W @ 230 V
cos φ= 0.3 Max. 1 A
Floor sensor| Floor Sensor NTC 15 kΩ at 25°C
Sensing values: (Default NTC 15 K) 0°C
20°C
50°C
| ****
42 kΩ
18 kΩ
6 kΩ
Control| Hysteresis ± 1.0° C
Ambient temperature| -10°C to +60°C
Frost protection temperature| 5°C to +9°C (default 5°C)
Temperature range| Room temperature: 5-35°C. Floor temperature: Max. 35°C is
default.
---|---
Sensor failure monitoring| The thermostat has a built-in monitoring circuit,
which will switch off the heating if the sensor is disconnected or short-
circuited
Cable specification max.| 1×4 mm2 or 2×2,5 mm2
Ball pressure test temperature| 75°C
Pollution degree| 2 (domestic use)
Controller type| 1C
Software class| A
Storage temperature| -20°C to +65°C
IP class| 30
Protection class| Class II –
Dimensions| 86 x 86 x 16/40.5 mm (in-wall depth: 24.5 mm)
Weight| 103 g
Electrical safety and Electro-Magnetic Compatibility for this product is covered by the compliance with the EN/IEC Standard “Automatic electrical controls for household and similar use”:
- EN/IEC 60730-1 (general)
- EN/IEC 60730-2-9 (thermostat)
Safety Instructions
Make sure the mains supply to the thermostat is turned off before installation.
Important: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C.
Please also note the following:
- The installation of the thermostat must be done by an authorized and qualified installer according to local regulations.
- The thermostat must be connected to a power supply via an all-pole disconnection switch.
- Always connect the thermostat to continuous power supply.
- Do not expose the thermostat to moisture, water, dust, and excessive heat.
Mounting Instructions
Please observe the following placement guidelines:
- Place the thermostat at a suitable height on the wall (typically 80-170cm.).
- The thermostat should not be placed in wet rooms. Place it in an adjacent room and use floor sensor only. Always place the thermostat according to local regulation on IP classes and use floor sensor only.
- Do not place the thermostat on the inner side of an exterior wall.
- Always install the thermostat at least 50 cm. from windows and doors.
- Do not place the thermostat in a way that it will be exposed to direct sunlight.
Note: A floor sensor enables a more accurate temperature control and is recommended in all floor heating applications and mandatory under wooden floors to reduce the risk of over-heating the floor.
- Place the floor sensor in a conduit in an appropriate place where it is not exposed to sunlight or draft from door openings.
- Equally distant and >2cm from two heating cables.
- The conduit should be flush with the floor surface – countersink the conduit if necessary.
- Route the conduit to the connection box.
- The bending radius of the conduit must be min 50mm.
Connect the thermostat according to the connection diagram.
The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.
Note: Always install the floor sensor in a conduit in the floor.
Symbols
The following symbols appears in the display:
Settings
Power ON/OFF
Switch the thermostat ON/OFF by pressing the button on top of the
thermostat.
Initial Settings
Initial settings must be specified when the unit is activated for the first
time: Press the M button for 6 seconds to enter the parameter setting mode.
The upper digits indicate the parameter number. Press M for parameter
selection.
Press < or > to set the parameter range. Complete all adjustments. Press to
exit ECtemp Next Plus settings, which is available for this purpose. To exit
ECtemp Next settings automatically wait approx. 30 seconds. The digits
indicate the set value as follows:
N o � | Parameter settings | Settings range | Default |
---|---|---|---|
P01 | Working mode | 01: Manual |
02: Advanced Program- mable Timer
| 02
P02| Temperature control mode| 01: Room and floor temp; 02: Only floor temp.;
03: Only room temp.*
| 01
P03| Maximum floor temperature| 20-30˚C (only for 01 in P02)**| 35˚C
---|---|---|---
P04| Frost protection| 01: Enable; 02: Disable| 01
P05| Frost protection setpoint| 5-9˚C| 5˚C
P06| Timer display option| 01: 24h; 02 12h| 01
P07| Room temp. display option at shutdown| 01: No display surrent temp.;
02: Display current temp.
| 01
- It will be possible to use only a room sensor. However, this option is not recommendable due to an increased risk of overheating the floor. See 4.9 Change to Room control only
- P03 appears on the relevant temperature control mode. See 4.10 Extending Maximum floor temperature limitations to 45°C
Advanced Programmable Timer
The Advanced Programmable Timer mode enables the set-ting of a timer- controlled program for automatic comfort temperature, and an energy-saving lower setback tempera-ture if standard room comfort temperature is not required. The function consists of 2 programs:
- P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)
- P2 with 4 events in 2 days (Sat. Sun.).
P1: Press and hold to display Mo. Tu. We. Th. Fr.
P1, Event 1:
1. Use < or > to select the start time.
2. Press to accept the setting.
3. Use < or > to select the temperature.
4. Press to accept the setting.
P1, Event 2-4:
Repeat the Event 1 procedure for programming Event 2-4.
| P2: Sa. Su. are now shown in the display.
P2, Event 1:
1. Use < or > to select the start time.
2. Press to accept the setting.
3. Use < or > to select the temperature.
4. Press to accept the setting.
P2, Event 2-4:
Repeat the Event 1 procedure for programming Event 2-4.
---|---
The thermostat will continue the 4-event program based on the present time and day.
To set and change the room temperature temporarily:
- Press < or > at any time to change the desired tem-perature value. SET is shown in the display.
- When releasing the < or >, the display returns to showing the actual temperature. This temperature change is only temporary and will be maintained only until the next programmed setting!
A default program provides timer control if the customer does not create own programs:
Days
| Event 1| Event 2| Event 3| Event 4
---|---|---|---|---
Start time| T emp| Start time| T emp|
Start time| T emp| Start time| T emp
Mon – Fri.| 6:30| 20˚C
(27˚C)*
| 8:30| 15˚C
(25˚C)*
| 16:30| 20˚C
(27˚C)*
| 22:30| 25˚C
(25˚C)*
Sat – Sun.| 7:30| 20˚C
(27˚C)*
| 9:30| 20˚C
(27˚C)*
| 16:30| 21˚C
(28˚C)*
| 22:30| 25˚C
(25˚C)*
- Only floor temperature control mode.
Temperature Setting
Changing of desired temperature – press < or >. SET is showed in the display. Adjustment is changed in steps of 0.5°C When releasing < or > again the display returns to normal mode and shows actual temperature. It will be possible to set the maximum floor temperature up to 45°C. It would also be possible to use only one temperature sensor. However, this option is not recommendable as this cause an increased risk of overheating of the floor. Extending maximum floor temperature and Setting into room only mode – See point 4.9 and 4.10.
IMPORTANT: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35 ° C.
Thermal resistance [m 2 K/W]| Examples of
Flooring| Details| Approximate setting for 25˚C floor
temperature
---|---|---|---
0.05| 8 mm HDF based lami- nate| >800 kg/m3| 28˚C
0.10| 14 mm beech parquet| 650 – 800
kg/m3
| 31˚C
0.13| 22 mm solid oak plank| >800 kg/m3| 32˚C
< 0.17| Max. carpet thickness suit- able for floor heating| acc. to EN 1307|
34˚C
0.18| 22 mm solid for planks| 450 – 650
kg/m3
| 35˚C
Timer Setting
To adjust time and week day – press Use < or > to adjust hours, Press again to shift to minutes and use < or > for adjust-ing Press again to shift to weekdays and use < or > for select-ing right day Finish timer setting by pressing any other button or wait for automatic exit after 6 sec. without operation
Safety Lock
Press M and > simultaneous to enable the Safety lock. To release the safety lock press M and > simultaneous again.
Away Mode
- Press M to get into Away mode is shown in the display Changing the desired temperature in Away mode Press < or >. SET is showed in the display Adjustment in steps of 0.5°C Press M to exit Away mode again
Present Floor Temperature
- Press M and hold – Press < within 6 sec also start to flash and the current floor temperature is being displayed. Press any other button to exit or wait for automatic exit after 6 sec. without operation
Change to Room control only
Switch Power OFF
Press M and Timer buttons simultaneously for approx. 10 seconds Select
Function P08: Only Room temperature control Select Setting 01: Enable
Switch Power ON
Press the M button for approx. 6 seconds Select Parameter Setting P02:
Temperature Control mode Select Setting Range 03: Room Only mode
Extending Maximum floor temperature limitation to 45°C
Power OFF
Press M and Timer buttons simultaneously for 10 seconds into those parameters
settings. Select Function P07 (Table in 4.11): Setting range extension for
P06, P07 and P08 Select Setting 02: Maximum 45°C Adjust Maximum Floor
temperature according to need up to 45°C
Power ON
Press the M button for 6 seconds Select P03 (Table in 4.2): raise floor
temperature limitation higher than 35°C by using the >
Table for Change to Room control only and Extending Maximum Floor temperature limitations to 45°C
No. | Function | Setting | Factory default |
---|
Danfoss ECtemp™ Next Plus
P01| Room Sensor Calibration| Offset:-10˚C to
+10˚C
| 0˚C
P02| Floor Sensor Calibration| Offset:-10˚C to
+10˚C
| 0˚C
P03| Maximum Room Temp. Limitation| 5-35˚C(Active in Temperature Control Mode
01)| ****
35˚C
P04| Minimum Room Temp. Limitation| 5-35˚C(Active in Temperature Control Mode 01)| ****
5˚C
P05| Maximum Room Temp. Limitation| 5-35˚C(Active in Temperature Control Mode 02)| ****
35˚C
P06| Minimum Room Temp. Limitation| 5-35˚C(Active in Temperature Control Mode 02)| ****
5˚C
P07| Setting range extension for P06, P07, P08| 01: Max. 35˚C, 02:
Max. 45˚C
| ****
01
Error Codes
- All relay output will be turned off in all cases.
Warranty
A 2-year product warranty is valid for:
- thermostats: ECtemp Next Plus.
Should you, against all expectations, experience a problem with your Danfoss product, you will find that Danfoss offers Danfoss warranty valid from the date of purchase on the following conditions: During the warranty period Danfoss shall offer a new comparable product or repair the product if the product is found to be faulty by reason of defective design, materials or workmanship. The repair or replacement. The decision to either repair or replace will be solely at the discretion of Dan-foss. Danfoss shall not be liable for any consequential or incidental damages including, but not limited to, damages to property or extra utility expenses. No extension of the warranty period following repairs undertaken is granted. The warranty shall be valid only if the WARRANTY CERTIFICATE is completed correctly and in accordance with the instructions, the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided. Please note that the WARRANTY CERTIFICATE must be filled in, stamped and signed by the authorized installer performing the installation (Installation date must be indicated). After the installation is performed, store and keep the WARRANTY CERTIFICATE and purchase documents (invoice, receipt or similar) during the whole warranty period. Danfoss warranty shall not cover any damage caused by incorrect conditions of use, incorrect installation or if installation has been carried out by non-authorized electricians. All work will be invoiced in full if Danfoss is required to inspect or repair faults that have arisen as a result of any of the above. The Danfoss warranty shall not extend to products that have not been paid in full. Danfoss will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers. The warranty explicitly excludes all claims exceeding the above conditions. For full warranty text please use the QR code
Disposal Instruction
Any information, including, but not limited to information on the selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in cataloques, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.
Intelligent Timer Thermostat Floor / Room Sensor 85-250V~ 50-60Hz -10°C to +60°C 16A/3680W@230V~ IP 30
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>