COBY CBPAC1080 Portable Air Conditioner User Manual
- June 12, 2024
- COBY
Table of Contents
COBY CBPAC1080 Portable Air Conditioner
Product Information
- Portable Air Conditioner
- Model: CBPAC1080 / CBPAC1080H
The Portable Air Conditioner is an easy-to-use appliance designed to provide cool air in any room. It comes with a model number and serial number, which can be found on a label at the rear of the unit. Make sure to record these numbers and staple your purchase receipt to the manual for warranty service purposes.
Product Usage Instructions
-
Read and understand all safety instructions before using the air conditioner.
-
Ensure the air conditioner is connected to a proper electrical outlet with the correct electrical supply.
-
Proper grounding is essential to reduce the risk of shock and fire. Do not cut or remove the grounding prong. If your wall does not have a three-prong electric receptacle outlet, contact a certified electrician to install the proper receptacle.
-
Check the power cord for any fraying or damage. If there are any cracks, abrasions, or malfunctions, do not use the unit.
Contact an authorized service technician for examination, repairs, or adjustments. A damaged cord must be replaced by the unit manufacturer. -
Avoid using adapters or extension cords to power the air conditioner.
-
Ensure there is no obstruction blocking the airflow around the air conditioner. The exhaust hose should be free of any obstructions.
-
Always unplug the air conditioner before servicing or moving it.
-
Avoid installing or using the air conditioner in areas with combustible gases, oily atmospheres, or sulphurous atmospheres.
Keep chemicals away from the air conditioner. -
Do not place any object on top of the unit.
-
Never operate the air conditioner without filters in place.
-
Avoid using the air conditioner near bathtubs, showers, or wash basins.
-
This appliance is not intended for use by individuals with reduced physical, sensory, or mental capabilities unless they have been given proper supervision or instruction.
-
Children should be supervised to ensure they do not play with the appliance.
-
If the supply cord is damaged, it must be replaced by the manufacturer, a service agent, or qualified persons to avoid hazards.
PRODUCT REGISTRATION
Thank you for purchasing our COBY product. This easy-to-use manual will
guide you in getting the best use of your air conditioner.
Remember to record the model and serial numbers. They are on a label on the
rear.
Model number
Serial number
Date of purchase
Staple your receipt to your manual.
You will need it to obtain warranty service.
SAFETY INFORMATION
DANGER – Immediate hazards which WILL result in severe personal injury or death
WARNING – Hazards or unsafe practices which COULD result in severe personal injury or death
CAUTION – Hazards or unsafe practices which COULD result in minor personal injury
IMPORTANT SAFETY INSTRUCTIONS
WARNING
When using electrical appliances, basic safety precautions should be followed,
including the following
- To reduce risk of injury, read this guide before using the appliance.
- Air conditioner must be connected to proper electrical outlet with the correct electrical outlet with the correct electrical supply.
- Proper grounding must be ensured to reduce the risk of shock and fire. DO NOT CUT OR REMOVE THE GROUNDING PRONG. If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle. The wall receptacle MUST be properly grounded.
- Do not operate air conditioner if power cord is frayed or otherwise damaged. Avoid using it if there are any cracks or abrasion damage along the length, plug connector or if the unit malfunctions or is damaged in any manner. Contact an authorized service technician for examination, repairs or adjustments. A damaged cord must be replaced with one by the unit manufacturer and not repaired.
- DO NOT USE AN ADAPTER OR AN EXTENSION CORD.
- Do not block airflow around the air conditioner. The exhaust hose should be free of any obstructions.
- Always unplug the air conditioner before servicing it or moving it.
- Do not install or use the air conditioner in any area where the atmosphere contains combustible gases or where the atmosphere is oily or sulphurous. Avoid any chemical coming in contact with your air conditioner.
- Do not place any object on the top of the unit.
- Never operate the air conditioner without filters in place.
- Do not use the air conditioner near a bathtub, shower or wash basin.
- This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities or lack of experience & knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, a service agent or similarly qualified persons in order to avoid a hazard.
- The air conditioner shall be installed in accordance with national wiring regulations.
HANDLING ALKALINE BATTERIES
WARNING
When handling alkaline batteries, basic safety precautions should be followed,
including the following
- Should fluid from the battery accidentally get into your eyes, there is a threat of loss of eyesight, do not rub them. Immediately rinse your eyes with clean tap water and then consult a physician immediately.
- Do not put the battery in a fire, expose it to heat, dismantle or modify it. If the insulation or safety valve is damaged, the battery may leak fluid, overheat or explode.
- Do not insert the battery with the poles reversed. Doing so may cause some abnormality or a short and the battery may leak fluid, overheat or explode.
- Keep the battery out of the reach of children. If the battery is swallowed, contact a physician immediately.
- If the alkali fluid gets in your mouth, rinse your mouth with water and contact a physician immediately.
- If the alkali fluid gets on your skin or clothes, it may burn your skin, thoroughly rinse the affected area with tap water.
- Do not mix new and old batteries or other makes of batteries. The different attributes may cause the battery to leak fluid, overheat or explode.
- This battery was not made to be recharged. Recharging this battery may damage the insulation or internal structure and may cause the battery to leak fluid, overheat or explode.
- Do not damage or remove the label on the exterior of the battery. Doing so may cause the battery to short, leak fluid, overheat or explode.
- Do not drop, throw or expose the battery to extreme impact. Doing so may cause the battery to leak fluid, overheat or explode.
- Do not alter the shape of the battery. If the insulation or safety valve is damaged, the battery may leak fluid, overheat or explode.
- Immediately remove batteries when they have lost all power. Leaving the batteries in the unit for a long time may cause the batteries to leak fluid, overheat or explode due to gas that is generated by the batteries.
- Remove the batteries from the unit when not using the unit for an extended period of time. The batteries may leak fluid, overheat or explode due to gas that is generated by the batteries.
- Do not apply solder directly to the batteries. The heat may cause the batteries to leak fluid, overheat or explode.
- Do not get the batteries wet. Doing so may cause the batteries to overheat
- Store batteries someplace out of direct sunlight where the temperature and humidity are not high. Not doing so may cause the batteries to leak fluid, overheat or explode. Also, it may cause the life and performance of the batteries to decline.
- Follow the regulations of the local government when disposing of these batteries.
- NEVER mix alkaline, standard (carbon-zinc), rechargeable (nickel-cadmium) batteries with this product.
SAVE THESE INSTRUCTIONS
HOUSEHOLD USE ONLY
GROUNDING INSTRUCTIONS
ELECTRICAL REQUIREMENTS
In the event of malfunction or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock.
The appliance must be connected to a cord having an equipmentgrounding
conductor and a grounding plug. The plug must be plugged into an appropriate
outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
DANGER – Improper connection of the equipment grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or service person if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug connected to the appliance – if it will not fit the outlet,have a proper outlet installed by a qualified electrician.
FOR GROUNDED, CORD-CONNECTED APPLIANCE RATED LESS THAN 15A AND INTENDED FOR
USE ON A NOMINAL 120V SUPPLY CIRCUIT
The appliance is for use on a nominal 120V circuit and should be connected to
a grounding outlet that looks like the one illustrated below. The use of a
temporary adaptor is not recommended.
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and
Interruption) power cord that is required by UL. This power supply cord
contains state-of-the-art electronics that sense leakage current. If the cord
is damaged and leakage occurs, power will be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the plug is
functioning properly.
WARNING: Test LCDI before each use.
-
To test the plug:
-
Plug power cord into a grounded 3 prong outlet.
Press RESET (on some units a green light will turn on). -
Press the TEST button, the circuit should trip and cut all power to the air conditioner(on some units green light may turn off).
-
Press the RESET button for use. You will hear a click and the A/C is ready for use.
-
The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset.
NOTES:
- Do not use this device to turn the unit on or off.
- Always make sure the reset button is pushed in for correct operation
WARNING:
- The power supply cord must be replaced if it fails to reset when either the test button is pushed, or it cannot be reset.
- If power supply cord is damaged, it cannot be repaired.
- It must be replaced by one obtained from the product manufacturer.
WARNING – RISK OF FIRE
It is important the plug fits tightly into the wall outlet.
If the plug does not fit securely and appears loose, it should not be used.
Have a licensed electrician replace the receptacle.
SAFETY GUIDELINES
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
ALWAYS DO THIS | NEVER DO THIS | ENERGY SAVE |
---|---|---|
• Your air conditioner | • Do not operate your air | • Use the unit in the |
recommended room size.
6,000 BTU
up to 250 sq. ft.
7,000 BTU
up to 300 sq. ft.
8,000 BTU
up to 350 sq. ft.
10,000 BTU
up to 450 sq. ft.
• Locate the unit where furniture cannot obstruct the air flow.
• Keep blinds / curtains drawn.
• Keep the filters clean.
• Keep doors and windows closed to keep cool air in and warm air out.
should be used in such a| conditioner in a wet room
way that it is protected| such as a bathroom or
from moisture. e.g.| laundry room.
condensation, splashed
water, etc. Do not place or store your air conditioner where it can fall or be
| • Do not touch the unit with wet or damp hands or when barefoot.
pulled into water or any| • Do not press the buttons
other liquid. Unplug| on the control panel with
immediately.| anything other than your
• Always transport your air| fingers.
conditioner in a vertical| • Do not remove any fixed
position and stand on a| covers. Never use this
stable, level surface during| appliance if it is not working
use.| properly, or if it has been
• Turn off the product when not in use.| dropped or damaged.
• Never use the plug to start
• Always use the switch on| and stop the unit.
the control panel to start or| • Do not cover or obstruct the
shut off the unit.| inlet or outlet grilles.
• Always contact a qualified| • Do not use hazardous
person to carry out| chemicals to clean or come
repairs. If the supply cord| into contact with the unit.
is damaged it must be| Do not use the unit in the
repaired by a qualified| presence of inflammable
technician.| substances or vapour such as
• Keep an air path of at least 12 inches. all around the| alcohol,
insecticides, gasoline,
etc.
unit from walls, furniture| • Do not allow children
and curtains.| to operate the unit
• If the air conditioner is| unsupervised.
knocked over during use,| • Do not use this product for
turn off the unit and unplug| functions other than those
from the power supply| described in this instruction
immediately.| manual.
OPERATING CONDITION
The air conditioner must be operated within the temperature range indicated below:
NOTE: · Unit performance may be affected when in use outside of these operating temperatures.
MODE | ROOM TEMPERATURE |
---|---|
COOL | 64˚F (18˚C) ~ 95˚F (35˚C) |
DEHUMIDIFY | 64˚F (18˚C) ~ 95˚F (35˚C) |
HEAT (ELECTRICAL HEAT TYPE) | 45˚F (7°C) ~ 81˚F (27˚C) |
PARTS & FEATURES
SPECIFICATIONS
-
CBPAC1080
Unit dimensions (W × D x H): 18.7″ x 15.5″ x 31″ -
СВРАС1080H
-
Unit dimensions (W × D × H): 18.7″ x 15.5″ × 31″
-
Electric Requirements: 115V – 60Hz
-
Unit Weight approx. 71.3 lbs.
-
Unit Weight approx. 72.1 lbs.
INSTALLATION GUIDE LOCATION
- The air conditioner should be placed on a firm floor to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit.
- The unit has casters to aid placement, but it should be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
- The unit must be placed within reach of a properly rated grounded socket.
- Never place any obstacles around the air inlet or outlet of the unit.
- Allow 12 inches to 36 inches of space from the wall with window for efficient air-conditioning.
SUGGESTED TOOLS FOR WINDOW KIT INSTALLATION
- Screwdrivers (medium size Phillips)
- Tape measure or ruler
- Knife or scissors
- Saw (In the event that the window kit needs to be cutdown in size because the window is too narrow for direct installation)
WINDOW SLIDER KIT INSTALLATION
“Horizontal” window applications; however, it may be necessary for you to
improvise/modify some aspect of the installation procedures for certain types
of window. Minimum and maximum window openings:
MAXIMUM: 59” (150 cm) MINIMUM : 29.5” (75 cm)
NOTE:
- Adjust the length of the window slider kit according to the window width or height,and secure it with the provided locking screws.
- If the window opening is less than 29.5” the minimum length of the window slider kit,cut the one with a hole in it short to fit for the window opening. Never cut out the hole in window slider kit.
DOUBLE-HUNG SASH/SLIDING CASEMENT WINDOW INSTALLATION
- Cut the foam seal (adhesive type) to the proper length and attach it to the window sash.
- Attach the window slider kit to the window sash. Adjust the length of the window slider kit according to the width of window. Shorten the adjustable window kit if the width of window is less than 29.5″.
- Cut the foam seal (adhesive type) to the proper length and attach it on the top of the window.
- Close the window securely against the window slider kit.
- Secure the window slider kit to the window sash.
- Cut the foam seal to an appropriate length and seal the open gap between the top window frame and outer window frame.
EXHAUST HOSE INSTALLATION
The air exhaust hose and hose inlet must be installed or removed from the
portable air conditioner in accordance with the way it is being used:
COOL, DEHUMIDIFY, HEAT (Heat model CBPAC1080H only):
Air exhaust hose and hose inlet should be connected to the portable air
conditioner.
FAN: Air exhaust hose and hose inlet should be disconnected from the portable air conditioner.
- Connect hose inlet to one end of air exhaust hose. Push hose inlet over the end of the hose, push in slightly and then start threading it on in a clockwise direction. (see Fig. 1)
- Connect hose outlet to other end of air exhaust hose. Push hose outlet over the end of the hose, push in slightly and then start threading it on in a clockwise direction. (see Fig. 2)
- Align the tabs on the hose inlet into the slots over the air outlet, insert and push down. (see Fig. 3)
- Insert the hose outlet into the window panel.
- Affix the hose outlet into the window slider kit and seal.
(Fig. 4 & 5)
NOTE: The exhaust hose can be compressed or extended moderately, but it is desirable to keep the length to a minimum. Also make sure that the hose does not have any sharp bends.
CONTROL PANEL
Pictures are for illustration purpose only. Your model may or may not have all the features.
OPERATING FROM THE CONTROL PANEL
The Control Panel enables you to manage all the main functions of the
appliance, but to fully exploit its potential, you must use the remote
control.
TURNING THE APPLIANCE ON
-
Plug into the dedicated electrical outlet.
-
Press the button until the appliance comes on. The last function active when it was turned off will appear.
Never turn the air conditioner off by unplugging from the outlet. Always press the power button , then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation. -
Note: Before pressing Power button make sure the condensate drain plug in the rear of the unit is securely in place to avoid any leaking.
-
Press the MODE button until the light corresponding to the required Mode lights up.
COOL MODE
Ideal for hot weather when you need to cool the room.
To set operation of the appliance correctly, press the or buttons until the
desired temperature is displayed. (See Fig. 7)
Then select the fan speed by pressing the Fan Speed Button until the light corresponding to the required fan speed lights up:
HIGH: The Fan operates at maximum to reach the required temperature as rapidly as possible.
MED: Reduces Fan noise level but still maintains cooling.
LOW: For quiet operation.
DEHUMIDIFY
Press the “MODE” button until the “DEHUMIDIFY” indicator light comes on.
- Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor operates at LOW speed.
- Keep window and door closed for the best dehumidifying effect.
- Exhaust hose attachment is not required to reduce humidity, however it is recommended in very humid rooms so the warm air can be exhausted outside.
DRAINING IN DEHUMIDIFICATION MODE
- It is recommended that the dehumidification drain and drain hose can be used for continuous drainage.
- FULL TANK – When the water level reaches a predetermined level, the “full tank” indicator light goes on. The unit will have to be drained.
NOTE: Refer to Water Drainage section.(page 21)
FAN MODE
- Press the “MODE” button until the “FAN” indicator light comes on.
- Press the speed button to select HIGH, MEDIUM or LOW fan speed. The temperature cannot be adjusted.
- Exhaust hose attachment is not required in this mode.
HEAT MODE (Heat model CBPAC1080H only)
Press the “MODE” button until the “HEAT” indicator light comes on.
- Press the or buttons to select your desired room temperature. The temperature can be set within a range of 61°F-88°F.
- Press the speed button to select HIGH, MEDIUM or LOW fan speed.
NOTE: At the beginning of this mode, you may have to wait a few seconds before the appliance starts to give out hot air.
TIMER
- To set the AUTO STOP timer. When the unit is ON, press the TIMER button.
- Press the or button to select the AUTO TIME by 1 hour increments, up to 24 hours. The LED Display will indicate the remaining time. Press the TIMER button again. The TIMER indicator light illuminates to show that the AUTO STOP program is initiated.
- To set the AUTO START timer. When the unit is OFF, press the TIMER button.
- Press the or button to select the AUTO TIME by 1 hour increments, up to 24 hours. The LED Display will indicate the remaining time. Press the TIMER button again. The TIMER indicator light illuminates to show that the AUTO START program is initiated.
- Pressing the POWER button or the TIMER button will cancel the AUTO START/STOP timed program and the timer indicator light will not be illuminated
SWING INDICATOR LIGHT
When this light is illuminated, it indicates that the air swing is activated
from the remote and the louvers will move up and down.
SLEEP INDICATOR LIGHT
When this light is illuminated, it indicates that SLEEP has been activated
from the remote control and that the temperature will gradually adjust.
OPERATING FROM THE REMOTE CONTROL
BATTERY INSTALLATION (BATTERIES NOT INCLUDED)
- Slide open the battery compartment cover.
- Insert 2 × “AAA”batteries as shown.
- Slide back the battery cover.
CAUTION: Use only AAA or IEC R03 1.5V alkaline batteries. Remove the batteries if the remote is not used for a month or longer. Do not attempt to recharge the batteries. Both batteries should be replaced at the same time. Do not dispose of the batteries in a fire as they man explode.
Point the remote control at the receiver on the appliance. The remote control
must be no more than 16 feet away from the appliance (without obstacle between
the remote control and the receiver).
The remote control must be handled with extreme care. Do not drop it or expose
it to direct sun light or sources of heat.
REMOTE CONTROL
- POWER BUTTON: Press to Turn ON or OFF
- TIMER BUTTON: Used to set a delay start or shut down time.
- MODE BUTTON: Each time you press the button COOL, DEHUMIDIFY, FAN, HEAT (model CBPAC1080H is selected)
- ˚C / ˚F SELECTOR BUTTON: Select Fahrenheit or Celsius.
- INCREASE: Increase the temperature setting.
- DECREASE: Decrease the temperature setting.
- SWING BUTTON: Activates the air swing of the louvers.
- FAN SPEED BUTTON: Used to select the HIGH, MED or LOW Fan speed.
- SLEEP BUTTON: Gradually adjusts the temperature.
LED Display Indicators
| Cooling mode| | Fan speed
| Dehumidify mode| | Swing
| Fan mode| | Timer on
| Heat mode
Heat model CBPAC1080H only
|
| Time
| Sleep
| Display temp. or hours| | Fahrenheit or Celsius.
POWER BUTTON
- Press to Turn Air Conditioner ON or OFF. Press LED button to illuminate the LED screen on the unit.
MODE BUTTON
- Press the mode button to scroll through COOL, DRY , FAN , HEAT (Heat model CBPAC1080H only)
- The corresponding symbol will illuminate on the LED display to indicate which mode is selected.
COOL
- Select the target temperature 61˚F – 88˚F (16˚C – 31˚C) by pressing the + or – buttons until the desired temperature is displayed on the LED screen.
- Press the Fan Speed Button to select Low, Medium, or High Speed.
DEHUMIDIFY
Ideal for reducing humidity.
- Keep window and door closed for the best dehumidifying effect.
- Exhaust hose attachment is not required to reduce humidity, however it is recommended in very humid rooms so the warm air can be exhausted outside.
Draining in Dehumidify mode
- It is recommended that the dehumidification drain and drain hose be used for continuous drainage.
- FULL TANK – When the water level reaches a predetermined level, the “full tank” indicator light goes on. The unit will have to be drained.
NOTE: Refer to Water Drainage section.(page 21)
- In this mode, fan speed is selected automatically by the appliance and can not be set manually.
FAN
- Press the Fan Speed Button to select Low, Medium or High Speed.
HEAT
- Select the target temperature 61˚F – 88˚F (16˚C – 31˚C) by pressing the + or – buttons until the desired temperature is displayed on the LED screen.
- Press the speed button to select HIGH, MEDIUM or LOW fan speed.
NOTE: At the beginning of this mode, you may have to wait a few seconds before the appliance starts to give out hot air.
SWING
- Press this button to activate the air swing of the louvers. Press it again to deactivate.
TIMER
- To set the AUTO STOP timer. When the unit is ON, press the TIMER button. The TIME ON/OFF symbol on the remote LCD display will blink.
- Press the + or – button to select the AUTO TIME by 1 hour increments, up to 24 hours. The Remote LCD Display will indicate the selected time. Press the TIMER button again to set the selected time. There will be a steady TIME ON/OFF symbol on the remote LCD display and the TIMER indicator light will be illuminated on the control panel of the unit to show that the AUTO STOP program is initiated.
- To set the AUTO START timer. When the unit is OFF, press the TIMER button. The TIME ON/OFF symbol on the remote LCD display will blink.
- Press the + or – button to select the AUTO TIME by 1 hour increments, up to 24 hours. The Remote LCD Display will indicate the selected time. Press the TIMER button again to set the selected time. There will be a steady TIME ON/OFF symbol on the remote LCD display and the TIMER indicator light will be illuminated on the control panel of the unit to show that the AUTO START program is initiated.
- Pressing the POWER button or the TIMER button will cancel the AUTO START/STOP timed program and the timer indicator light will not be illuminated
SLEEP
- The SLEEP function gradually adjusts the temperature of the rooms to provide a comfortable environment. Press the SLEEP button to activate.
- In COOL mode, the temperature will increase 1°F after an hour and 2°F after 2 hours.
- In HEAT mode, the temperature will decrease 1°F after an hour and 2°F after 2 hours.
- To cancel this setting press the SLEEP button again.
°C / °F SELECTOR BUTTON
- When the appliance is powered on, press the °C / °F button, then you can select the unit of temperature from Fahrenheit or Celsius.
WATER DRAINAGE FOR COOLING AND HEAT MODES
This air conditioner is equipped with auto water evaporation so the water
compartment would not typically fill in cooling or heating mode unless there
is high humidity. Water drainage will generally only be required at the end of
the season for these modes. (see START-END OF SEASON OPERATIONS).
NOTE: FULL TANK – When the water level reaches a predetermined level, the “full tank” indicator light located on the control panel of the unit goes on. If an error code appears on the display screen on the control panel “E2” in COOL mode or “E4” in HEAT mode. The unit will have to be drained.
Intermittent Draining
- Unplug the unit from the power source. Carefully move the unit to a drain area over your basement floor or drip pan (not included). Remove the bottom drain cap.
- Let the water drain away and replace the drain cap. Restart the machine until the error codes E2 or E4 disappears. If the error repeats, call for service.
NOTE: Be sure to reinstall the bottom drain plug before using the unit.
Continuous Draining
- Unplug the unit from the power source. Remove the bottom drain cap. While doing this operation some residual water may spill so have a drip pan (not supplied) to collect the water.
- Connect the drain hose (supplied) as shown in the diagram. The water can be continuously drained through the hose into a floor drain or drip tray.
- Turn on the unit.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
- After the unit has stopped, it cannot be restarted for 3 minutes. Operation will automatically restart after 3 minutes.
CLEANING & CARE
CLEANING
WARNING: Before cleaning or maintenance, turn the appliance off by pressing the button on the control panel or button on the remote control. Unplug from the electrical outlet.
CLEANING THE CABINET
You should clean the appliance with a slightly damp cloth then dry with a dry
cloth.
- Never saturate the air conditioner with water.
- Never use petrol, alcohol or solvents to clean the appliance.
- Never spray insecticide liquids or similar near the air conditioner.
CLEANING THE FILTER
To keep your air conditioner working efficiently, you should clean the
evaporator filter every week of operation.
The filter is housed in the intake grill
Use a vacuum cleaner to remove dust accumulations from the filter.
If it is very dirty, immerse in warm water and rinse a number of times.
The water should be luke warm.
After washing, leave the filter to dry then re-insert the filter.
START-END OF SEASON OPERATIONS
START OF SEASON CHECKS
Make sure the power cable and plug are undamaged.
Follow the installation instructions precisely.
END OF SEASON OPERATIONS
See Water Drainage section to make sure the air conditioner is completely
drained of water.
Clean the filter and dry thoroughly before reinstalling.
TROUBLESHOOTING & WARRANTY
BEFORE YOU CALL FOR SERVICE
IF THE AIR CONDITIONER FAILS TO OPERATE:
- Check to make sure that the air conditioner is plugged in securely. If it is not, remove the plug from the outlet, wait 10 seconds and plug it in again securely.
- Check for a blown circuit fuse or a tripped main circuit breaker. If these seem to be operating properly, test the outlet with another appliance.
WARNING
- IF NONE OF THE ABOVE SOLVES THE PROBLEM, CONTACT A QUALIFIED TECHNICIAN. DO NOT TRY TO ADJUST OR REPAIR THE AIR CONDITIONER YOURSELF. Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
- Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of the flammable refrigerants.
CUSTOMER SERVICE
IMPORTANT
DO NOT RETURN THIS PRODUCT TO THE STORE
If you have a problem with this product, please contact the W Appliance Co.
Customer Satisfaction Center at
1-855-855-0294. DATED PROOF OF
PURCHASE, MODEL # AND SERIAL # REQUIRED FOR WARRANTY SERVICE
Caution: Risk of fire/flammable materials
(Required for R32/R290 units only)
IMPORTANT NOTE: Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
TROUBLESHOOTING
Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, contact W Appliance Co. customer service center or the nearest authorized service center. Customers must never troubleshoot internal components.
TROUBLE | POSSIBLE CAUSE | POSSIBLE REMEDY |
---|---|---|
The air conditioner does not work. | A. There is no electricity. | A. Turn unit |
on after connecting it to a socket with electricity.
B. Discharge the water inside.
C. Run the unit within the ambient temperature range of 44-95°F (7- 35°C).
D. Change the set temperature.
E. Place the unit in a room with an ambient temperature of greater than 62°F(17°C).
| B. The overflow indicator
displays FL.
| C. The ambient temperature is too low or too high.
|
D. In cooling mode, the room temperature is lower than the set temperature.
| E. In dehumidification mode, the ambient temperature is low.
The cooling effect is not good.| A. There is direct sunlight.
B. Doors or windows are open;
there are a lot of people in the room; or in cooling mode, there are other sources of heat.
C. The filter screen is dirty.
D. The air inlet or outlet is blocked.
| A. Pull the room curtain closed.
B. Close doors and windows, and add new air conditioner.
C. Clean or replace the filter
screen.
D. Clear obstructions.
Loud Noise| A. The air conditioner is not
placed on a flat surface.
| A. Put the air conditioner on a flat and hard place (to reduce noise).
Compressor does not work.| A. Overheat protection is active.| A. Wait for 3
minutes until unit cools, then restart.
The remote control does not work.| A. The distance between the unit and the
remote control is too far.
B. The remote control is not aligned with the direction of the remote control receiver.
| A/B. Move the remote control closer to the air conditioner, and make sure
that the remote control directly faces in the direction of the remote control
receiver on the unit.
| C. Batteries are dead.| C. Replace batteries.
Display reads E2| A. The coil temperature sensor is malfunctioning.| A. Ask
help from certified
technician.
Display reads E1| A. The room temperature sensor is malfunctioning.| A. Ask help from certified
technician.
LIMITED WARRANTY
Any repair, replacement, or warranty service, and all questions about this
product should be directed to W Appliance Co. at
1-855-855-0294 from the USA or Puerto
Rico.
W Appliance Co. warrants to the original purchaser that the product will be
free from defects in material, parts and workmanship for the period designated
for this product. The warranty commences the day the product is purchased and
covers up to a period of 1 year (12 months) for labor/1 year (12 months) for
parts (manufacturing defects only).
W Appliance Co. agrees that it will, at its option, replace the defective
product with either a new or remanufactured unit equivalent to your original
purchase during the warranty period.
Exclusions: This warranty does not apply to the below:
- If the appearance or exterior of the product has been damaged or defaced, altered or modified in design or construction.
- If the product original serial number has been altered or removed or cannot be readily determined.
- If there is damaged due to power line surge, user damage to the AC power cord or connection to improper voltage source.
- If damage is due to general misuse, accidents or acts of God.
- If repair attempts are done by unauthorized service agents, use of parts other than genuine parts or parts obtained from persons other than authorized service companies.
- On units that have been transferred from the original owner.
- On products that have been purchased as refurbished, like new, second-hand, in a “As-Is” or “Final Sale” terms.
- To products used in a commercial or rental setting.
- To products used in settings other than ordinary household use or used other than in accordance with the provided instructions.
- To damages for service calls for improper installations.
- Transportation and shipping costs associated with the replacement of the unit.
- Service calls to instruct you how to use your product.
- Service calls to repair or replace the house fuse, reset the circuit breaker or correct the wiring in the house.
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY
OF THE CUSTOMER; W Appliance Co.. SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR
CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS
PRODUCT, EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW. ANY IMPLIED
WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE ON THIS
PRODUCT IS LIMITED TO THE DURATION OF THE WARRANTY.
Some states do not allow the exclusion or limitations of incidental or
consequential damages, or limitations on how long the warranty lasts. In these
cases the above exclusions or limitations may not apply to you. This warranty
gives you specific legal rights and you may also have other rights which vary
from state to state.
Obtaining Service: To obtain service, product literature, supplies or
accessories please call 1-855-855-0294
to create a ticket for exchange/repair. Please make sure to provide the date
of purchase, model number and a brief description of the problem. Our customer
service representative will contact you or send detailed return instructions.
Appliance Co. does not warrant that the appliance will work properly in all
environmental conditions, and makes no warranty and representation, either
implied or expressed, with respect to the quality, performance,
merchantability, or fitness for a particular purpose other than the purpose
identified within this user’s manual. W Appliance Co. has made every effort to
ensure that this user’s manual is accurate and disclaims liability for any
inaccuracies or omissions that may have occurred. Information in this user’s
manual is subject to change without notice and does not represent a commitment
on the part of W Appliance Co.. W Appliance Co. reserves the right to make
improvements to this user’s manual and/or to the products described in this
user’s manual at any time without notice. If you find information in this
manual that is incorrect, misleading, or incomplete, please contact us at
1-855-855-0294.
W Appliance Co.
1356 Broadway
New York, NY 10018
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: 1) This device may not cause harmful
interference, and 2) This device must accept any interference received,
including interference that may cause undesired operation. This equipment has
been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that the interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged
to try to correct the interference by one or more of the following measures:
a) Reorient or relocate the receiving antenna. b) Increase the separation
between the equipment and the receiver. c) Connect the equipment into an
outlet different from that which the receiver is connected. d) Consult the
dealer or an experienced radio/TV technician for help.
© 2022 W Appliance Company. All Rights Reserved. 1356 Broadway, New York, NY 10018
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>