Numatic HVW370 Henry Wash Owner’s Manual

October 30, 2023
Numatic

Numatic HVW370 Henry Wash Owner's Manual

Numatic HVW370 Henry Wash Owner's Manualwww.numatic.co.uk

Please refer to information for wet vacuum cleaners BEFORE use at rear of manual.

Kit AS-6

Numatic HVW370 Henry Wash - Kit AS-6

Filling your machine

Numatic HVW370 Henry Wash - Filling your machine

Carpet Cleaning Assembly

Numatic HVW370 Henry Wash - Carpet Cleaning Assembly 1 Numatic HVW370 Henry Wash - Carpet Cleaning Assembly
2

NuChem 4

INSTRUCTIONS FOR USE TEST FOR COLOUR FASTNESS

Find a small area on the material which is not normally on view and test the carpet / fabric for colour fastness by rubbing with a cloth dampened with correctly diluted Nuchem 4. Do not use on velvet type materials or any materials not suitable for wet cleaning according to fabric manufacturers cleaning instructions.

For Normal soiling: Pour one 40ml Measure into 5 litres of cold water.

For Heavy Soiling: Pour two 40ml Measure into 5 litres of cold water.

NuChem 4 is non-foaming, bactericidal, contains optical brightners and leaves no tacky residues in the fabric and is enhanced with both a delicate and discreet verbena scent.

P102: Keep out of reach of children.
P 305+351+338:

IF IN EYES:
Rinse continuously with water for several minutes.
Remove contact lenses,if present and easy to do.
Continue rinsing.

Numatic HVW370 Henry Wash - NuChem 4

Using your machine (Carpet Cleaning)

Numatic HVW370 Henry Wash - Using your machine \(Carpet
Cleaning\)

Hard Floor Assembly

Assemble machine steps 1-5 (Page 3)

Numatic HVW370 Henry Wash - Hard Floor Assembly

Using your machine (Hard Floor Cleaning)

Numatic HVW370 Henry Wash - Using your machine \(Hard Floor
Cleaning\)

Upholstery Cleaning Assembly

Assemble machine steps 1-4 (Page 3)

Numatic HVW370 Henry Wash - Upholstery Cleaning
Assembly

Using your machine (Upholstery Cleaning)

Numatic HVW370 Henry Wash - Using your machine \(Upholstery
Cleaning\)

Cleaning the machine

Numatic HVW370 Henry Wash - Cleaning the machine

Fitting the face

Numatic HVW370 Henry Wash - Fitting the face

Removing the face

Numatic HVW370 Henry Wash - Removing the face

Carrying your Henry Wash & cable storage

Numatic HVW370 Henry Wash - Carrying your Henry Wash & cable
storage

Schematic diagram

Numatic HVW370 Henry Wash - Schematic diagram

(GB) About your machine

Numatic HVW370 Henry Wash - About your machine

MAINTENANCE

Daily

Keep the machine clean, including hoses and tubes.
Ensure the bag and filter are fitted, (Dry use).
Empty dust bag if required.
Clean and check float safety valve for signs of damage.
Regularly examine the power cord.
Check filters are clean.
Weekly – as daily and:-
Check for any worn or damaged parts and replace immediately.

WEEE Legislation (Waste, Electrical and Electronic Equipment)

Vacuum cleaner, accessories and packaging should be sorted for environmentally – friendly recycling.

(Only for UK/EU Countries)

Do not dispose of vacuum cleaner into household waste! According to the European Directive 2012/19/EU on waste electrical and electronic equipment and its incorporation into national law.

Vacuum cleaners that are no longer suitable for use must be separately collected and sent for recovery in an environmentally – friendly manner.

PPE (personal protective equipment). That may be required for certain operations.

Numatic HVW370 Henry Wash - PPE

NOTE : A risk assessment should be conducted to determine which PPE should be worn.

Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or the Numatic Technical helpline +44 (0)1460 269268

Mains leads:
Safety Critical Components
HO5-VV-F 10 m x 2 Core x 1.00 mm2

Information for Spray / Extraction use Vacuum Cleaners

Warning

Read the instruction manual before using the machine.
Operators shall be adequately instructed on the use of these machines.
As with all electrical equipment, care and attention must be exercised at all times during use, in addition to ensuring that routine and preventative maintenance is carried out periodically to ensure safe operation.
Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render this equipment unsafe and the manufacturer can accept no responsibility in this respect.
The machine shall be disconnected from the mains by removing the plug from the power supply socket during cleaning or maintenance and when replacing parts or converting the machine to another function.
This machine is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge.
Children being supervised are NOT to play with the machine.
This appliance is intended to be assembled, cleaned and maintained by an adult.
This machine is not a toy.
This machine is not suitable for picking up hazardous or explosive dust.
Contact your local distributor if you require a machine capable of performing these tasks.
If foam/liquid comes out of machine exhaust, switch off immediately.
Allow the accumulated liquid to drain out through the machine exhaust, check the float assembly to ensure correct operation, empty the container if full of liquid, reassemble the machine.
Immediately upon start up there will be a certain amount of liquid issuing from the machine exhaust which will be the residue of liquid still within the power head.
This will be quickly discharged after which the machine should function normally.
Liquid ejected from the machine could be hazardous as a result of its temperature, pressure or chemical content.

Caution
Ensure that the filtration system fitted to the machine is suitable for the material being collected.
This machine is for indoor use only.
This machine shall be stored indoors only. .
When moving from one place to another, consider the weight of the machine.

Notes
You must ensure that the filtration system fitted to the machine is suitable for the material being collected.
This product complies with the requirements of IEC/EN 60335-2-68.
This product complies with the requirements of clause 20 of IEC/EN 60335-2-69 for Stability and Mechanical Hazards.
The primary use for this machine is commercial, for example in hotels, schools, hospitals, factories, shops and offices.
If the vacuum cleaner stops working, remove the plug from the power supply before investigating where the fault lies.
The vacuum cleaner should be inspected after use for damage.
The power light will illuminate, when your machine is connected to a suitable power supply (where fitted).

Do

  • Use a bag and filter at all times when using `dry’.
  • Keep your machine clean.
  • Keep filters clean.
  • Regularly clean the water level limiting float safety valve and examine for signs of damage or correct operation.
  • Keep hoses and tubes clear.
  • Replace any worn or damaged parts immediately.
  • Regularly examine the power cord, if damage is found, power cord must be replaced by a qualified person using the correct Numatic original part.

Don’t

  • Use steam cleaners or pressure washers to clean the machine or use the machine in the rain.
  • Immerse in water for cleaning.
  • Allow any inexperienced repairs. Call the experts.
  • Use wet if float valve is not functioning or fitted.
  • Use to suck up hot ashes, or lighted cigarette ends.
  • Run the machine over the power cable during operation as a hazard may occur.
  • Pull on the cable to unplug the machine from the power supply.
  • Walk over-wet carpets, upholstery or fabrics.
  • Walk on clean carpets until fully dry.
  • Attempt machine maintenance or cleaning unless the power supply plug has been removed from the supply outlet.
  • Under any circumstances place foreign objects including (but not limited to) air fresheners, air freshener capsules or scented beads of any type into the top filter of the machine. Doing so can be dangerous and risk damage to the machine and may invalidate the machine warranty.

Fault Finding

This machine can be used for dry pick up, wet pick up and cleaning carpet and upholstery
Spray extraction machines only
· Use only approved cleaning preparations.
· Use defoamer if necessary.
Use of detergents
When using any detergent with this machine, please ensure you have read the safety data on the container and you are familiar with the procedures to clear up spills, inhalation, skin and eye contact.

Dry Mode maintenance/fault finding

If the vacuum cleaner stops working switch off and remove the plug from the power supply before investigating were the fault lies.
If the vacuum cleaner will not pick up any debris from the surface, switch off and remove the plug from the power supply, inspect the floor tool, wands and hose for blockages, if no blockages are found, the dust bag may be full if the dust bag is not full the filter may be blocked.

Wet mode / Spray extraction maintenance/fault finding

If the vacuum cleaner stops working switch off and remove the plug from the power supply before investigating were the fault lies.
If the vacuum cleaner has a blockage and will not pick up liquid, switch off and remove the plug from the power supply, has the float valve operated, this will shut off the suction and the pitch of the vacuum motor will change.
Remove the power head and empty the liquid out of the container, if the container is empty, check that the floor tool wands and hose are not blocked.
If the spray nozzle is blocked a pin maybe used to clear the blockage.
No spray from nozzle and the pump tone changes, the solution tank is empty, refill the solution tank.
Flush the system with clean water after use.
After use always inspect the machine for damage.

Numatic HVW370 Henry Wash - Specs

Warranty

Numatic HVW370 Henry Wash - Warranty

Declaration of Conformity

Numatic HVW370 Henry Wash - Declaration of Conformity
1 Numatic HVW370 Henry Wash - Declaration of
Conformity 2

Numatic International Limited.
Chard, Somerset TA20 2GB ENGLAND
Tel: 01460 68600 www.numatic.co.uk

Numatic International GmbH. Fränkische Straße 15­19
D-30455 Hannover, DEUTSCHLAND
Tel: 05 11 98 42 16 0 www.numatic.de

Numatic International SAS. 13 / 17 rue du Valengelier
EAE La Tuilerie ­ 77500 CHELLES, FRANCE
Tel: 01 64 72 61 61 www.numatic.fr

Numatic International BV
Vennootsweg 15, 2404 CG, Alphen aan den Rijn, NEDERLAND
Tel: 0172 467 999 www.numatic.nl

Numatic International (Pty.) Ltd.
16th & Pharmaceutical Roads, Midrand, Gauteng,
SOUTH AFRICA 1685
Tel: 0861 686 284 www.numatic.co.za

Numatic International Schweiz AG.
Sihlbruggstrasse 3A, 6340 Baar. SCHWEIZ
Tel: 0041 (0) 41 76 80 76 – 0  www.numatic.ch

Numatic International ULDA.
Rua da Boa Viagem, 177 4470.210 Maia. PORTUGAL
Tel: +351 220 047 700 www.numatic.pt

Numatic International SLU.
C/ La Forja, 41, 08840 Viladecans (Barcelona), Spain
Tel: +34 93 647 22 22 www.numatic.es

Specification subject to change without prior notice
www.numatic.co.uk © Numatic International Limited

908945 05/22 (A05)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals