Emaux FSP350-6W Filter and Pump Combo Instruction Manual

June 12, 2024
Emaux

Emaux FSP350-6W Filter and Pump Combo Instruction Manual
Emaux FSP350-6W Filter and Pump Combo

INSTALLATION

  • Install filtration system including pump,filter tank and multiport valve.
  • The filter system should be installed as close as possibie to the swimming pool and preferably at a level of 0.50 metres below the surface of the water in the swimming pool. Make sure there is drainage available at the place where the filter is to be installed.
  • PUMP
  1. Only qualified,licensed personnel should install pump and wiring.

  2. Electrical Contractors Please Note:All 220 volt 50Hz pump must be wired to the main power supply trough an approved and correctly rated contractor.

  3. Allow for gate valve in suction piping.

  4. Pump suction and discharge connections have moulded in thread stops,do not try to screw pipe in beyond these stops.
    * FILTER TANK and MULTIPORT VALVE

  5. Loading the sand media.Filter sand media is loaded through the top opening of the filter.
    a) Loosen the plastic clamps from tank neck.
    b) Cap internal pipe with plastic cap to prevent sand from entering it.
    c) We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the filter sand is poured in. This helps protect the under-drain laterals from excessive shock.
    d) Carefully pour in correct amount and grade of filter sand.Be sure center pipe remains centered in opening. Sand surface should be leveled and should come to about the middle of the filter tank.Remove plastic cap from internal pipe.

  6. Assemble filter control valve to filter tank.
    a) Insert filter control valve(with O’ring in place)into the tank neck,taking care that the center pipe slips into the hole in the bottom of the valve.
    b) Place two plastic clamps around valve flange and tank neck and tighten just enough so that the valve mayBe rotated on tank for final positioning.
    c) Carefully screw pressure gauge(with O’ring in place)into tapped hole in valve body.Do not overtighten.
    d) Connect pump to control valve opening marked PUMP with hose.After connections are made, tighten clamps with screwdrive,tapping around clamp with screwdrive handle to help seat valve flange clamp.

  7. Make return to pool pipe connection to control valve opening marked RETURN and complete other necessary plumbing connections,suction lines to pump,waste,etc.

  8. To prevent water leakage,be sure all pipe connections are tight.

INSTALL/START-UP OF FILTRATION

  1. Be sure correct amount of filter media sand is in tank and that all connections have been made and are secure.

  2. Depress control valve handle and rotate to BACKWASH position. (To prevent damage to control valve seal, always  depress handle before turning.)

  3. Prime and start pump. Never tun pump dry! Running pump dry may damage seals,causing leakage and flooding!
    Fill pump with water before starting motor. (be sure all suction and return lines are open), allowing the filter tank to fill with water. Once water is flowing out of the waste line, run the pump for at least 1 minute. The initial back washing of the filter is recommended to remove any impurities or fine sand particles in the sand media.

  4. Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear, about 1/2 to 1 minute. Turn pump off and set valve to FILTER position and restart pump.The filter is now operating in the normal filter mode, filtering dirt particles from the pool water.

  5. Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and tighten connections, bolts, nuts, as required.

  6. Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending upon the pump and general piping system.) As the filter removes dirt and impurities from the pool water, the accumulation in the filter will cause the pressure to rise and flow to diminish. When the pressure gauge reading is 1.5 bar, higher than the initial “clean” pressure you noted, it is time to backwash the filter (see BACKWASH under filter and control valve functions)

NOTE: During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually heavy initial dirt load in the water.

REPLACEMENT PARTS OF FILTER

Parts List

Item Part No. Description Qty
1 88280105 1. 5″ Top Mount Valve 1
2 89280101 1. 5″ union with sight glass, O- Ring 1
3 89280102 1. 5″ Union Set With O- Ring 1
4 06021013 Plastic Pressure Gauge With O- Ring ( 40psi) 1
01111048 Connector for pressure gauge 1
5 89030204 Hose adaptor with O- Ring 1
6 02011026 Sleeve for Hose 2

7

| 89031501| FSP350- 6W Plastic Hose with Nut| 1
89031601| FSP400- 6W Plastic Hose with Nut| 1
89031701| FSP450- 6W Plastic Hose with Nut| 1
89031801| FSP500- 6W Plastic Hose with Nut| 1
89031901| FSP650- 6W Plastic Hose with Nut| 1
8| 01013049| Hose adaptor with nut| 1
9| 02011104| O- Ring for pump| 1

10

| 08030006| SS020(220V/50Hz)| 1
08030007| SS033(220V/50Hz)| 1
08030008| SS050(220V/50Hz)| 1
08030009| SS075(220V/50Hz)| 1
08030010| SS100(220V/50Hz)| 1
08030011| SS120(220V/50Hz)| 1
11| 89032001| Pump Assembly Screw| 2
12| 89010119| M6* 50 Screws With Nut| 2
01271010| Clamp  Lock| 2
13| 02011134| O- Ring for Filter Neck| 1

14

| 01331005| P350 Filter Tank| 1
01331006| P400 Filter tank| 1
01331007| P450 Filter tank| 1
01331008| P500 Filter tank| 1
01331010| P650 Filter tank| 1
15| 89011602| P350 Lateral Assembly with Center Pipe| 1
16| 89011603| P400 Lateral Assembly with Center Pipe| 1
89011604| P450 Lateral Assembly with Center Pipe| 1
89011605| P500 Lateral Assembly with Center Pipe| 1
89011606| P650 Lateral Assembly with Center Pipe| 1
17| 01172007| P400- P450 Laterals ( 115mm)| 8
01172008| P500- P650 Laterals ( 126mm)| 8
18| 89011601| Water Drain Set| 1
19| 01111056| FSP350 Combo Base| 1
01111053| FSP400-FSP650 Combo base| 1

SS PUMP REPLACEMENT PARTS

Parts List

Item Port No. Description Qty
1 01201031 Transparent Lid 1
2 02011074 0-Ring for lid 1
3 01112051 Basket 1
4 01021064 SS Pump Pre filter 1
5 89280105 1.5–union 2
6 89022402 Drain Plug With 0′ ring I
7 02011004 0-Ring for diffuser 1
8 01111014 Diffuser I
9 01311015 Impeller SS020(220V 501-1z) 1
01311016 Impeller 3S023(220V/50Hz) 1
01311017 Impeller SS050 (220V/50Hz) 1
01311018 Impeller SS075 (220V/50Hz) 1
01311019 Impeller SS100(220V 50Hz) 1
01311014 Impeller SS120(220V 5011z) 1
10 89022403 M8$16 Screw with washer 4
II 04015033 1/2–Mechanical seal 1
12 02011090 0 Ring for Flange 1
13 01021065 SS Pump Flange 1
14 03011035 M6*30 Screw 8
15 02011156 Motor Slinger for SS020-SS033 1
15 02011153 motor Slinger for 55050-55I20 1
16 89022404 Motor support 1
17 89022109 Motor S5020(220V150Hz) 1
89022110 Motor 55033(220V/50Hz) 1
89022105 Motor S5050(220V.:50Hz) 1
89022106 Motor S5075(220V/50Hz) 1
89022107 Motor SS100(220V/50Hz) 1
89022108 Motor S5I20(220V/50Hz) 1
18 04016009 Capacitor for 55050 Pump(220V/50Hz/60Hz) 1
04016010 Capacitor for 55075 Pump(220W50Hz/60Hz) 1
04016012 Capacitor for SSI00, SSI20 Pump(220V/50Hz/60Hz) 1
04016030 Capacitor for SS020 Pump(220V/50Hz/60Hz) 1
04016031 Capacitor for 55033 Pump(220V…•50H7/60Hz) 1
19 89022112 Cable Box for 55050-55120 Pump 1
20 89022111 Cable Box for SS020-SS033 Pump 1
21 01031027 Cooling fan for 55050-55120 Pump 1
01031026 Cooling fan for S5020 55033 Pump 1
22 01031011 Fon Cover for $5020 55033 Pump 1
01031010 Fan Cover for S5050-53120 Pump 1
23 02011104 0-Ring 2

PRIMING PUMP

  • Release all air from filter and piping system.
  • In a flooded suction system (water source higher than pump), pump will prime itself when suction and discharge valves are opened.
  • If pump is not in a flooded suction system, unscrew and remove trap cover; fill trap and pump with water.
  • Clean and inspect Ring; re-install on trap cover.
  • Replace trap cover on trap; turn clockwise to tighten cover.

NOTICE: Tighten trap cover by hand only .Pump should prime now. Priming time will depend on vertical length of suction lift and horizontal length of suction piping.

VALVE REPLACEMENT PARTS

Parts List

Item Part No. Description Qty
1 01013003 Handle (Big) 1
2 03018008 Pin for Handle 1
3 01181001 Washer for Handle 1
4 89280107 M6 x 30 Screw with Nut for Standard Lid 6
5 01013004 1.5″ Top/Side Mount Valve Standard Lid (Black) 1
6 02011002 O-Ring for 1.5″ Valve Lid 1
7 01181002 Washer for Spring 1
8 03014001 Spring for 1.5″ Top/Side Mount Valve 1
9 02011022 O-Ring for Valve Rotor 2
10 01021001 1.5″ Valve Rotor 1
11 02311002 Spider Gasket 1
12 E190147 1.5″ Body with Diffuser (Black) 1
13 02011001 O-Ring for Diffuser 1
14 02020013 O-Ring for 1.5″Connector 3
15 01013015 1.5″ Connector (Black) 3
16 02011003 O-Ring for 1.5″ Adaptor 3
17 01171153 1.5″ Union (A/E)(Black/White) 2
18 01013017 1.5″ Union Nut (Black) 3
19 01041002 1.5″ Union with Sight Glass (Short) 1
20 01172026 1.5″ Union with Sight Glass Holder(Black/White) 1
21 89280120 Drain Plug Fitting with O-ring 1
22 89021307 Drain Plug with O-ring 1
23 06021013 Plastic Pressure Gauge with O-ring 1
Valve Position Function
--- ---
FILTER Normal Filtration and Vacuuming
BACKWASH Cleaning Filter by reversing the flow
RINSE Used after backwash to flush dirt from valve
WASTE By-passes filter, used for vacuuming to waste or lowering water level
RECIRCULATE By-passes filter for circulating water to pool
CLOSED Shuts off all flow to filter or pool

WARNING

THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE.
TURN PUMP OFF BEFORE CHANGING VALVE POSITION.
TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM.CLEAN PUMP STRAINER AND SKIMMER BASKETS REGULARLY.
DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING

Emaux Logo

Documents / Resources

| Emaux FSP350-6W Filter and Pump Combo [pdf] Instruction Manual
FSP350-6W, FSP400-6W, FSP450-6W, FSP500-6W, FSP650-6W, FSP350-6W Filter and Pump Combo, FSP350-6W, Filter and Pump Combo
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Emaux User Manuals

Related Manuals