Emaux WTD-CB Water Descent Control Box Instruction Manual

June 9, 2024
Emaux

Emaux WTD-CB Water Descent Control Box

PART LIST

Emaux-WTD-CB-Water-Descent-Control-Box-
fig-1

Item No. Part No. Product Description QTY
1 03011007 M4×12 Screws 8
2 04014054 Lighted Switch 1
3 01360015 Panel Board 1
4 03011196 M3×6 Screws 5
5 03011023 M5×35 Screws 4
6 04014013 Cable Gland 4
7 87013019 Plastic Fitting 4
8 89480103 Remote control with Battery 1
9 04014094 Control Panel Cover 1
10 04014095 Control Panel 1
11 04012082 Transformer with Wiring Cap 1
12 89480101 Control Box 1
13 89480102 Cable with Wiring Cap 1

WATER DESCENT CONTROL BOX

Model: WTD-CB
Keep this manual safe for future reference

APPLICABLE FOR EMAUX WATER DESCENTS:
PB300-25(L)/PB600-25(L)/PB900-25(L)/PB1200-25(L) PB300-150(L)/PB600-150(L)/PB900-150(L)/PB1200-150(L) PB300-230(L)/PB600-230(L)/PB900-230(L)/PB1200-230(L)

Warning:

This electrical control box must be installed by a licensed or certified electrician or a qualified serviceman in accordance to the requirements of your government standard or local authorities. Improper installation will create electric hazards which could result in serious injury, death as well as damage to the property.

CUT THE POWER BEFORE SERVICE AND MAINTAINANCE!

INSTALLATION EXPLAIN

  1. Remove the Panel from the Control Box, position the box to the desired fitting place and mark on the wall with the location of the drilled holes, then drill 4 holes of ø8mm on the marked position and insert a plastic fitting, secure the box by fastening 4 screws of M5x35 to the plastic fittings(See diagram below).
  2. Feed the LED lights Cable through the cable gland(s) and connect the cable as shown in the Control Box Wiring Diagram. Reassemble the panel cover and secure the Panel by fastening 4 screws of M4x12.
  3. If multiple Water Descents are being installed, the pre-set holes on the side of the Control Box can be used.

CONTROL BOX INSTALLATION DIAGRAM

SPECIFICATIONS

Working Temperature -20~+40?
Input AC 100-240V; 50/60Hz
Output DC 12V, 60W
Frequency RF 433MHz

CONTROL BOX WIRING DIAGRAM

Warning: load of the control box should not exceed 60W. CONTROLS INDEX

Emaux-WTD-CB-Water-Descent-Control-Box-fig-5

PATTERN TABLE

No. PATTERNS REMARKS
1 Static white
2 Static blue
3 Static green
4 Static cyan
5 Static purple
6 Static yellow
7 Three-color change Red, Green, Blue
8 Seven-color change White, Red, Yellow, Blue, Green, Cyan, Purple
9 Seven-color gradual change(Fast) White, Red, Yellow, Blue, Green, Cyan,

Purple
10| Seven-color gradual change(Slow)| White, Red, Yellow, Blue, Green, Cyan, Purple

The setting of the Remote Control

Operation distance for the remote control is 25m.Emaux-WTD-CB-Water-Descent-
Control-Box-fig-6

Each control box is associated with a remote control. To use a single remote to control a multiple number of control boxes, you would need to configure the Frequency at the back of the remote control. The Frequency of the Remote would then need to be synced with all the control boxes.

  • Slide open the back of Remote Control
  • Set the Frequency
  • Turn on Control Box(es)
  • Sync the Remote to the Control Box(es)
  • Press the Sync Button until the lights on the Control Boxes turn on

If you have multiple control boxes and you want to use a remote control for a specific control box, you must set the Frequency on the remote control to a unique combination.

  • Slide open the back of Remote Control
  • Set a unique Frequency on the Remote Control
  • Turn on the Control Box associated with that particular Remote Control
  • Sync the Remote to the Control Box
  • Press the Sync Button until the lights on the Control Box turn on
  • Once synced, turn off the control box and move to the next set of Control Box and Remote. Repeat above steps.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Emaux User Manuals

Related Manuals