INSTALLATION AND OPERATION
MANUAL
![NO. SIGN POSSIBLE CAUSES CORRECTIVE ACTIONS
1
Battery working time is too short The charging voltage is lower than 14.4V, and the battery charging capacity is less than 100Ah Use the standard charge voltage
The load is too high, and the battery ends discharging prematurely Reduce load wattage
The ambient temperature is too high or too low, and the battery cannot be fully charged or discharged \(capacity drop at low temperature range\) Keep working at normal ambient temperature
The battery life is naturally attenuated, the capacity is reduced, and the working time is short Replace the battery
2 BMS keeps cutting off during discharge Discharge current is too high, trigger overcurrent protection Reduce discharge current
Voltage is too low, trigger low voltage protection Recharge the battery
3 BMS keeps cutting off during charge Charge current is too high, trigger overcurrent protection Reduce charge current
Voltage is too high, trigger high voltage protection Disconnect the charger
4 BMS keeps cutting off when batteries connected in series or parallel
One battery triggers over-voltage, under-voltage and over-current protection, etc. Check the load and charger situation. Ensure the system works under the specification
5
Bluetooth not detected Battery under sleep mode Activate the battery
More than 10m away from the battery Make sure the battery needs to be connected is within a reasonable distance
The Bluetooth of the mobile phone does not detect the battery Check the phone's Bluetooth function
6
Battery gets too hot Frequent overload use/high current draw Use according to battery specifications
Working with the maximum continuous charge and discharge current for a long time, the heat dissipation environment is poor, resulting in heat accumulation Ensure a good heat dissipation environment
7
Battery no voltage reading The battery is over-discharged below 10V and is lower than the working voltage of the BMS, the BMS cannot work normally Recharge the battery in time and confirm that the battery can be switched on normally. If the battery cannot be turned on again, replace the battery
BMS power supply line is damaged, BMS cannot work normally Replace the battery
Internal power cord disconnected Replace the battery
BMS failed Replace the battery
8
Sleep mode cannot be deactivated The activation voltage is 1.2V lower than the battery voltage Ensure that the charging activation voltage is 1V higher than the battery voltage
The current of load is too small Disconnect the load and reconnect the load to ensure that load resistance <5k▲
9 Battery external damage - terminal, cover, casing
Improper operation such as drop, impact, etc.
Replace the battery
10
Battery exploded High voltage due to improper charging causes BMS to fail, and the battery is not protected
Replace the battery
Instant violent collisions, squeezing, puncture, rupture etc. making the battery unable to release energy](https://manuals.plus/wp-content/uploads/2023/03/Emaux-SSC-Series-Chlorinator-.png) **USER MANUAL
Model: SSC Series
**
SAFETY WARNINGS
This appliance must be installed in accordance with national wiring codes and with a means of disconnection incorporated in any fixed wiring. High voltage can shock, burn, or cause death or serious property damage.
- In order to reduce the risk of electric shock DO NOT use an extension cord to connect the unit to electric supply.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a qualified electrician.
- The system must be permanently connected to an individual circuit breaker, especially when pump power is connected from pump socket of the device.
- This electricity supply must be connected through a residual current device (RCD) or Ground Fault Circuit Interrupter (GFCI) with a rated residual operating current not exceeding 30 mA.
- Electrical grounding must be connected before connecting to electrical power. Failure to ground all electrical equipment can cause electric shock or serious or fatal injury.
- Before servicing, unplug the power plug from the electrical socket and allow the device to cool for at least 15 minutes.
- Never unplug the cell cable during operation.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
HYPERTHERMIA
Always unplug the device from its socket or power source and allow it to cool
before opening the enclosure. There is high risk of shock and burn injuries
from touching the internal component.
COMPRESS AIR HAZARDOUS
This system enclosed titanium cell in a plastic enclosure that can become
pressurized. Pressurized air can cause the plastic enclosure to explore
causing serious injury or death. The cell must be operated with the pump
running and the valves fully open allowing water to flow unrestricted through
the cell enclosure.
This device is intended for use with swimming pools and spas only; it must not
be used for disinfecting drinking water.
Only one pump and one underwater light may be connected to this unit (SSC-TLT
Series Only)
The current loading of the pumped connected must not exceed 8 Amp. ( SSC-TLT
Series Only)
Correct disposal of this product | |
---|---|
This symbol on the product, or in its packaging, indicates that this product |
may not be treated as household waste. Instead, it should be taken to the appropriate waste collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by the inappropriate waste handling of this product. For more detailed information about the recycling of this product, please contact your local council, your household waste disposal service, or the shop where you purchased the product.
SAFE POOL SANITIZING WORKING PRINCIPLE
Chlorine is a highly effective sanitizing agent which is commonly used in swimming pools. It can prevent the growth of bacteria and fungi. This chlorinator uses the process of electrolysis to break down the salt (NaCl) in the swimming pool water to produce chlorine gas (Cl₂ ) Chlorine production can be regulated from the control unit by altering the electric current flowing through the titanium electrode in the cell housing.
2.1 WATER CHEMISTRY:
**** It is important to note that the EMAUX Chlorinator does not maintain the water chemistry of your swimming pool water; it simply produces chlorine from a mild salt solution. To ensure that your chemical balances is within the guidelines listed below and to encourage a sparling clean, you should also have your water tested regularly at your local pool shop.
Salt level | SSC15-E / SSC15-T / SSC15-TLT | 3000 – 4000 ppm |
---|---|---|
SSC25-E / SSC25-T / SSC25-TLT | 3000 – 4000 ppm | |
SSC50-E/SSC50-T | 4000 – 5000 ppm | |
Free Chlorine | 1.0 – 3.0 ppm | |
pH | 7.2 – 7.6 | |
Cyanuric acid (stabilizer) | 30 – 50 ppm | |
Total Alkalinity | 80 – 120 ppm | |
Calcium Hardness | 200 – 400 ppm | |
Metals | 0ppm |
2.2 CHLORINE LEVEL CALCULATION
2.3 SALT LEVEL
The amount of salt required is between 4000 and 6000 ppm. This can be done by
adding 4-6Kg of salt per 1,000 litres of water directly into the pool water.
A low concentration of salt (below 2500 ppm) will cause premature cell
failure.
A High concentration of salt (above 6000 ppm) may cause electro-oxidation and
corrosion damage to the Stainless Steel pool fixtures and fittings.
Salt required according to the volume of the pool:
Pool volume (m3) | Salt (kg) | Pool volume (Gallon) | Salt (Pound) |
---|---|---|---|
10 | 40 | 2,642 | 88 |
15 | 60 | 3,963 | 132 |
20 | 80 | 5,283 | 176 |
25 | 100 | 6,604 | 220 |
30 | 120 | 7,925 | 264 |
35 | 140 | 9,246 | 308 |
40 | 160 | 10,567 | 352 |
50 | 200 | 13,209 | 440 |
60 | 240 | 15,850 | 528 |
70 | 280 | 18,492 | 616 |
80 | 320 | 21,134 | 704 |
90 | 360 | 23,775 | 792 |
100 | 400 | 26,417 | 880 |
110 | 440 | 29,059 | 968 |
120 | 480 | 31,700 | 1,056 |
150 | 600 | 39,626 | 1,320 |
Note: Table based on 4000 ppm of salt per m of water.
2.4 TYPE OF SALT
The most common salt used in swimming pools with Salt Electrolysis is 99% pure
Sodium Chlorine (NaCl).
DO NOT use the following types of salts:
- Rock salt.
- Salt with more than 1% yellow prussiate of soda.
- Salt with more than 1% of anti-caking additives.
- Iodized salt. Salt with additives or impurities will cause premature cell failure.
2.5 ADDITION AND REMOVING SALT IN THE SWIMMING POOL WATER
Before adding the salt into the pool, place the multiport valve on “
Filtration ” or “ Recirculation” and then turn the filtration pump on.
Add the salt directly into the pool evenly around the pool or ballast tank. Do
not allow the salt to sit in a pile on the bottom of the pool.
Do not add large amount of salt nearby the skimmer at the same time. It will
damage the unit.
Keep the filtration system running for 24 hours using the Main Drain or vacuum
suction nozzle as a main suction line.The only way to remove the salt in the
pool water is to partially drain the pool and refill with fresh water.
PRODUCT FEATURES
- Convenience and the constant delivery of pure chlorine-based sanitizer.
- No more artificial chemical cleaning agent which could cause skin and eye irritation. You just need to add natural salt in the pool.
- The salt in the water is so little you do not taste or smell the salt.
- The electrode is made of titanium, which is durable and resistant to corrosion.
- Easy to install and operate.
- The water does not have the heavy smell of chlorine because chlorine is not directly added to the pool.
Product Picture
3.1 PRODUCT DIMENSIONS
3.2 PRODUCT SPECIFICATION
Model| Cell power Rating (VA)| Chiorine Generation (g/hr)| Fiberglass Pool
(Liter)| Concrete Pool (Liter)
---|---|---|---|---
SSC15-E| 142| 15| 50000| 45000
SSC25-E| 226| 25| 75000| 70000
SSC50-E| 500| 45| 120000| 110000
SSC15-T| 142| 15| 50000| 45000
SSC25-T| 226| 25| 75000| 70000
SSC50-T| 500| 45| 120000| 110000
SSC15-TLT| 142| 15| 50000| 45000
SSC25-TLT| 226| 25| 75000| 70000
All the cells are Self Cleaning type
SSC-TLT Series (Chlorinator with underwater light, transformer and time
switch)
Model| **** Input Voltage / Frequency| Underwater light transformer Power
Rating
---|---|---
SSC15-TLT| 220-240VAC 50/60Hz| 100VA
SSC25-TLT| 220-240VAC 50/60Hz| 100VA
SSC-T Series (Chlorinator with time switch)
Model | Input Voltage / frequency | Power Rating |
---|---|---|
SSC15-T | 220-240VAC 50/60Hz | 142VA |
SSC25-T | 220-240VAC 50/60Hz | 226VA |
SSC50-T | 220-250VAC 50/60Hz | 500VA |
INSTALLATION GUIDE
The Emaux SSC Chlorinator unit is contained in a rain tight enclosure that is suitable for outdoor mounting (IPX4 waterproof). However, the following points must be taken into consideration for a correct installation of the Superior SSC Chlorinator unit:
-
Select a convenient well-ventilated location within one meter of filter equipment.
-
The cell must be installed above the sand filter discharge outlet water level.
-
If the chlorinator and cell are installed below water level, the pump and chlorinator must have a common power switch in o rder to prevent the chlorinator from generating chlorine while the pump is not running. Otherwise the cell enclosure will overheat and explode if only the pump is shut off.
-
Install the Control Panel using the template paper sheet provided with the package in a minimum distance of 3.5 meters (11.5 ft.) from the swimming pool, 1.5 meters (5 ft.) from the ground, within 2 meters (6.5 ft.) from the protected outlet, and within 4.5 meters (15 ft.) from where the cell will be installed, in a ventilated area and leaving enough free space of min. 50 cm (20”) in each side for servicing.
-
Two self-tapping screws and wall plugs are provided for fast and simple installation. Simply cut out the template provided for the location of the drilling points. Use a 8mm masonry drill when fitting the control unit to a brick or concrete wall. When mounting to a post, drill pilot holes and fit the screws provided. Once the screws are in position simply hang the chlorinator via the bracket on back of the control box.
-
The cell must be installed horizontally
-
The electrolytic cell housing must be plumbed into the return line after the filter. The cell housing can be fitted to 1.5: or 2” PVC piping by provided universal union.
-
Connect the water inlet and outlet to the Cell Unit. The water flow direction must be as indicated on the Cell.
-
To avoid loss of chlorine, the Cell should be installed at the end of the filtration system, right before the pool water return.
-
The cell should preferably be installed on a bypass with input and output gate valves. This will permit uninterrupted filtration while the chlorinator is being serviced. The inlet and outlet valves must not be closed during operation, otherwise pressure will build up in the plastic enclosure and it will explode.
-
Glue the salt cell horizontally on the pool return pipe, allow the pipe glue to cure for 24 hours.
-
Use the provided cable to connect the control unit and the salt cell together.
- For model with power socket for pump, the maximum allowed power rating is 1,500 Watt or 1.5HP. Refer to pump model plate for power rating confirmation.
- DO NOT mount the Control Panel under direct sun light.
- The Control Panel must be installed far away from the chemical storage, especially from acid because it can corrode the electronics inside the unit.
- It must be kept away from heat sources and any equipment which produce heat.
- Plug-in power supply into a suitable weatherproof outlet socket with circuit breaker.
- Before fixing the Control Panel, make sure that the power cable and cell cable also reach the Control Panel.
For model with built-in lighting power output:
Mount the control unit vertically onto a post or wall 1.5 meters above ground
level. (Australian Standards
requires that the electric control unit shall not be located within 3 meters
of the pool water.)
START UP
Never allow the chlorinator operate without water flow. The pump and chlorinator must operate simultaneously.
- Recommended pool salt lever: 3000- 4000PPM for SSC15 and SSC25, 4000-5000PPM for SSC50.
- Run chlorinator at the Salt Levels stated within this document and on the product to ensure optimum sanitizer output and cell life.
- Operating this device at low salt levels will damage the cell and reduce its life.
- The control panel will display a RED indicator when the salt level is low.
- If no action is taken to rectify the salt level, damage to the cell may result which will not be covered under warranty.
- During extreme hot weather conditions or high bather load, the pool water need to be super-chlorinated using powder, granulated, or liquid chlorine or the running time of the chlorinator should be increased.
- Always turn down the system control to zero before adding salt, once the salt is completely dissolved, return to the set position.
- The aluminum casing at the back of the Control Unit acts as a heat sink, do not touch it with bare hands.
CONTROL PANEL OPERATION
6.1 DIGITAL DISPLAY
There are three display functions:
- When system control button is tuned from left to right, it adjust the cell output ratio and display the corresponding running time per hour. For example, “100 “means 60 minutes, “50” means 30 minutes run and 30 minutes idle.
- In normal operation, it represent the percentage of the chlorine production. “100” means 100% chlorine is being generated with adequate salt level.
- System Error code, system stop and need attention
Error code | Description | Solution |
---|---|---|
ER2 * | Terminal inside temperature is too high | Switch off. Allow to cool. |
Open the case to check the cell terminal screw is tight. Restart.
ER3| Thermal sensor is disconnected| Check the sensor cable is not loose.
ER4| AC line input issue| Check the transformer output wiring, or fuse is
broken
- ER2- for protection, the system will stop operate when a worst environment is detected, such as too high salt level, high ambient temperature or insufficient ventilation.
LED DISPLAY
Operation
| 1| 2| Description
---|---|---|---
Green| Green| Normal Operation
Green| Red| Low salt/Deposition on the electrode/ Low water Temperature
Red| Red| Extremely low salt level / heavy deposition on the electrode
/extremely low water temperature
System Control| ON| OFF| Description
Green| | System control less than 100%, under operating
| Red| System control less than 100%, under idle time
Cell Polarity| +| –| Description
Red| | The cell current in positive direction
| Red| The cell current in negative direction
SALT CHLORINATOR ON/OFF/AUTO: ON/Off Switch. In Auto mode, the chlorinate is
operated by the timer setting.
Light On/Off: Switch for underwater light connected to the control unit (For
certain models) System Control button: Adjust the length of time of
chlorinator production.
For example: 76
Set at 100% = the salt cell operate continually.
Set at 50% = the salt cell operate for 30 minutes in each hour and is idle for
30 minutes.
Set at 30% = the salt cell operate for 18 minutes in each hour and is idle for
42 minutes.
Winter Mode Switch and On/ Off LED: Turn on to change the chlorine production
to 85% of the system production setting.
Cell Polarity LED: Shows the polarity of the electrodes; the polarity of the
electrode will reverse every 8 hours, in order to remove any deposit on the
electrode.
Timer: (timer models only) Programs the on and off times for the unit and pump
to run automatically.
Stand-By LED: Displays when the chlorinator is in stand-by mode. When the
chlorinator is turned on, the standby LED will go off after 35 seconds. No
Flow LED: Displays
when there is no water flow. If there is no water in the cell enclosure, the
pump and salt chlorinator will stop automatically.
TIMER SETTING FOR TIMER VERSION
- Turn the clock face until the time of the day is aligned with the clock at the center of the timer hand.
- The 24-hour dial has 15 minutes division. The timer can be programmed by pushing the captive trippers to the outer ring position for the entire period that the load is to be turn ON.
- The timer clock will rotate with time; the chlorinator will be turned on automatically if its captive tripper is pushed outward.
MAINTENANCE AND TROUBLESHOOTING
A salt chlorinator is a valuable piece of pool sanitizing equipment. Regular care and maintenance will ensure the best performance and long life. Keep the water chemical balance
- Maintain the correct water chemical balance
- Maintain a good operating environment
- Regularly check the condition of the titanium plates. During the chlorination process white calcium scale may naturally build up on the titanium plates in the cell. Regular monitoring of the cell will prevent excessive buildup of scale. Excessive scale will damage the cell and significantly reduce its life and efficiency.
- If the control box fails or there is excessive calcium deposit, maintenance must be carried out by a pool professional.
- Prevent insects from entering the control box, they may damage the electrical components inside.
TROUBLE SHOOTING
How To Handle |
---|
Salt level is too high and causing over heat.
| Check the salt level is within operation range, refer to individual model
recommendation. It will resume output when salt level is normal.
Check the electrical plug/control box/ pump power| Connect the power properly
System setting is too low| Turn the system control to maximum
Automatically stopped by the timer setting| Adjust the timer setting
Blown fuse| Unplug the power and replace the fuse
Excessive scale build up on the cell
| Switch off the salt chlorinator and request cleaning the salt cell by
professional pool service.
Water temperature too low| Turn on the winter switch
Salt lever too low| Add salt to the pool
|
Pump malfunction| Stop the filtration system and repair the pump
Filter Backwashing| Once the backwash is complete, turn the filter back to
normal filtration
The gas sensor is not connected| Connect the gas senor according to this
manual
|
System setting too low| Turn the system control to maximum
Display 888| Replace the Internal fuse
ELECTRICAL WIRING
10.1 MAIN PCB
The main controller PCB has two connectors.
- 13 pins flat cable connector for the power module
- 4 pins cable connector, blue and gray color pins connect to the power switch.
10.2 POWER MODULE
A salt chlorinator is a valuable piece of pool sanitizing equipment.
Regular care and maintenance will ensure the best performance and long life.
Keep the water chemical balance
- Maintain the correct water chemical balance
- Maintain a good operating environment
- Regularly check the condition of the titanium plates. During the chlorination process white calcium scale may naturally build up on the titanium plates in the cell. Regular monitoring of the cell will prevent excessive buildup of scale. Excessive scale will damage the cell and significantly reduce its life and efficiency.
- If the control box fails or there is excessive calcium deposit, maintenance must be carried out by a pool professional.
- Prevent insects from entering the control box, they may damage the electrical components inside.
SSC15 & SSC25 no fuse
SSC50 is 30A.
10.3 TRANSFORMER
The transformer has two voltage inputs:
240Vac (blue) for Australia, New Zealand and UK.
220Vac (white) for rest of the world.
Avoid burn injuries: Do not touch the transformer before switching it off and
allowing it to cool.
10.4 TERMINAL BLOCK
The terminal block in the middle of the chassis is used to select input AC
voltage 220V or 240V, input power fuse protection and connectionto transformer
input.
CLEANING THE TITANIUM CELL
Although the system is designed with a self-cleanig function for the cell
(reverse polarity), it will occasionally be necessary to manually clean the
cell to remove calcium deposit.enclosure, the pump and salt chlorinator will
stop automatically.
Caution
AThe mixture required for cleaning is extremely corrosive and protective
clothing should be worn.
Procedures
Make up a dilute mixture of 1:10 parts of Hydrochloric (muriatic) Acid to
water
Always add Hydrochloric acid to water
- Turn the filtration system off.
- Remove the salt cell from the housing.
- Add the salt cell to the cleaning mixture making avoiding contact with the terminals.
- Wait five to ten minutes for the Salt Cell to be cleaned.
- If any parts of calcium are stuck or will not dissolve, carefully remove them with a smooth plastic instrument.
- Once the salt cell is clean, rinse with fresh water and place back in the housing and tighten the cell or collar.
- Turn system back to automatic setting or timer. Dispose of cleaning mixture.
If the salt cell has a heavy deposit of calcium that has not been removed after ten minutes in the cleaning solution, we recommend using a “Cell Cleaner” product which is not as corrosive as hydrochloric acid. The cell can then be left in the cleaner for up to a hour and will completely remove the calcium. We recommended using Salt Cell Cleaner at all times over the traditional Hydrochloric mixture, it is a safer alternative and not harmful to your Salt Cell at all and reusable.
TERMS OF THE WARRANTY
As original purchaser of this equipment have purchased from Emaux Water
Technology Co Ltd, through Authorized International Distributor or Dealer,
warrants its products free from defects in materials and workmanship under
normal use during warranty period. The warranty period begins on the day of
purchase and extends only to the original purchaser. It is not transferable to
anyone who subsequently purchases the product from you. It excludes all
expendable parts.
During the warranty period, Emaux authorized reseller will repair or replace
defective parts with new parts or, at the option of Emaux, serviceable used
parts that are equivalent or superior to new parts in performance.
This Limited Warranty extends only to products purchased from Emaux authorized
reseller. This Limited Warranty does not extend to any product that has been
damaged or rendered defective (a) as a result of accident, misuse or abuse;
(b) as a result of an act of God;
(c) by operation outside the usage parameters stated herein;
(d) by the use of parts not manufactured or sold by Emaux;
(e) by modification of the product;
(f) as a result of war or terrorist attack; or
(g) as a result of service by anyone other than Emaux authorized reseller or
authorized agent.
EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, EMAUX MAKES NO OTHER
WARRANTIES EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OR
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. EMAUX EXPRESSLY
DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY IMPLIED
WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS EXPRESS
LIMITED WARRANTY.
Installation template
Ratio 1:1
EMAUX WATER TECHNOLOGY CO., LTD
ADDRESS FLAT A-D, 20/F., KAI BO 22, 22 WING KIN ROAD,
KWAI CHUNG, HONG KONG PHONE +852 2832 9880
STRIVE FOR CLEAR WATER
www.emauxgroup.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>