MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor Unit User Manual

June 12, 2024
Mitsubishi Electric

SPLIT-TYPE AIR CONDITIONERS

Revision A:
• MSZ-GS06/09/12/15/18/24NA – U1,
MSY-GS09/12/15/18/24NA – U1,
MSZ-GS30/36NA2 – U1 and
MSY-GS30/36NA2 – U1
have been added.
OBB874 is void.

INDOOR UNIT
No. OBB874
REVISED EDITION-A

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit

MSZ-GS18NA
MSY-GS18NA

MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor Unit

PARTS CATALOG
Models

MSZ-GS06NA – U1
MSZ-GS09NA – U1
MSZ-GS12NA – U1
MSZ-GS15NA – U1
MSZ-GS18NA – U1
MSZ-GS24NA – U1
MSZ-GS30NA – U1
MSZ-GS36NA – U1
MSZ-GS30NA2 – U1
MSZ-GS36NA2 – U1| MSY-GS09NA – U1
MSY-GS12NA – U1
MSY-GS15NA – U1
MSY-GS18NA – U1
MSY-GS24NA – U1
MSY-GS30NA – U1
MSY-GS36NA – U1
MSY-GS30NA2 – U1
MSY-GS36NA2 – U1
---|---

Revision A:
• MSZ-GS06/09/12/15/18/24NA – U1, MSY-GS09/12/15/18/24NA – U1, MSZ-GS30/36NA2 – U1 and MSY-GS30/36NA2 – U1 have been added.

SERVICE PARTS LIST

MSZ-GS06NA MSZ-GS09NA MSZ-GS12NA MSZ-GS15NA MSY-GS09NA MSY-GS12NA MSY-GS15NA
1-1. INDOOR UNIT STRUCTURAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 1

1-2. ACCESSORY AND REMOTE CONTROLLER

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 2

1-1. INDOOR UNIT STRUCTURAL PARTS
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS06NA – U1| MSZ-GS09NA – U1| MSZ-GS12NA – U1| MSZ-GS15NA – U1| MSY-GS09NA – U1| MSY-GS12NA – U1| MSY-GS15NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---|---|---|---
1| U01 A03 234| BOX ASSEMBLY| 1| 1| 1| | 1| 1| | |
1| U01 A04 234| BOX ASSEMBLY| | | | 1| | | 1| |
2| U01 A04 000| PANEL ASSEMBLY| 1| 1| 1| 1| 1| 1| 1| | Includes No. 3, 4, and 5
3| U01 A01 142| CATCH| 2| 2| 2| 2| 2| 2| 2| | 2 PCS/SET
4| U01 A01 067| SCREW CAP| 2| 2| 2| 2| 2| 2| 2| | 2 PCS/SET
5| U01 A02 010| FRONT PANEL| 1| 1| 1| 1| 1| 1| 1| |
6| U01 A01 100| AIR FILTER (NANO PLATINUM FILTER)| 2| 2| 2| 2| 2| 2| 2| | 1 PC/SET
7| U01 A01 975| CORNER BOX (RIGHT)| 1| 1| 1| 1| 1| 1| 1| |
8| U01 A01 970| INSTALLATION PLATE| 1| 1| 1| 1| 1| 1| 1| |
9| | AIR CLEANING FILTER (ANTI-ALLERGY ENZYME FILTER)| 2| 2| 2| 2| 2| 2| 2| | MAC-408FT-E 2 PCS/SET

1-2. ACCESSORY AND REMOTE CONTROLLER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS06NA – U1| MSZ-GS09NA – U1| MSZ-GS12NA – U1| MSZ-GS15NA – U1| MSY-GS09NA – U1| MSY-GS12NA – U1| MSY-GS15NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---|---|---|---
10| U01 A16 426| REMOTE CONTROLLER| 1| 1| 1| 1| | | | | SH22A
10| U01 A17 426| REMOTE CONTROLLER| | | | | 1| 1| 1| | SH22B
11| U01 A20 426| REMOTE CONTROLLER HOLDER| 1| 1| 1| 1| 1| 1| 1| |

MSZ-GS06NA MSZ-GS09NA MSZ-GS12NA MSZ-GS15NA MSY-GS09NA MSY-GS12NA MSY- GS15NA
1-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 3

1-3. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS06NA – U1| MSZ-GS09NA – U1| MSZ-GS12NA – U1| MSZ-GS15NA – U1| MSY-GS09NA – U1| MSY-GS12NA – U1| MSY-GS15NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---|---|---|---
1| U01 A02 510| BEARING MOUNT ASSEMBLY| 1| 1| 1| 1| 1| 1| 1| |
2| U01 A01 702| DRAIN HOSE| 1| 1| 1| 1| 1| 1| 1| |
3| U01 A01 235| NOZZLE ASSEMBLY| 1| 1| 1| 1| 1| 1| 1| |
4| U01 A01 040| VANE-UPPER| 1| 1| 1| 1| 1| 1| 1| |
5| U01 A01 041| VANE-LOWER| 1| 1| 1| 1| 1| 1| 1| |
6| U01 A01 303| VANE MOTOR| 1| 1| 1| 1| 1| 1| 1| MV|
7| U01 A08 308| ROOM TEMPERATURE THERMISTOR| 1| 1| 1| 1| 1| 1| 1| RT11|
8| U01 A38 452| ELECTRONIC CONTROL P.C. BOARD| 1| | | | | | | |
8| U01 A39 452| ELECTRONIC CONTROL P.C. BOARD| | 1| | | | | | |
8| U01 A40 452| ELECTRONIC CONTROL P.C. BOARD| | | 1| | | | | |
8| U01 A41 452| ELECTRONIC CONTROL P.C. BOARD| | | | 1| | | | |
8| U01 A42 452| ELECTRONIC CONTROL P.C. BOARD| | | | | 1| | | |
8| U01 A43 452| ELECTRONIC CONTROL P.C. BOARD| | | | | | 1| | |
8| U01 A44 452| ELECTRONIC CONTROL P.C. BOARD| | | | | | | 1| |
9| U01 A01 978| CONDUIT PLATE| 1| 1| 1| 1| 1| 1| 1| |
10| U01 A01 979| CONDUIT COVER| 1| 1| 1| 1| 1| 1| 1| |
11| U01 A03 440| POWER P.C. BOARD| 1| 1| 1| 1| 1| 1| 1| |
12| U01 A09 308| INDOOR COIL THERMISTOR| 1| 1| 1| 1| 1| 1| 1| RT12, RT13|
13| U01 A01 385| VARISTOR| 1| 1| 1| 1| 1| 1| 1| NR11|
14| U01 001 239| FUSE| 1| 1| 1| 1| 1| 1| 1| F11| T3.15AL250V
15| U01 A01 784| V.A. CLAMP| 1| 1| 1| 1| 1| 1| 1| |
16| U01 A21 426| INDOOR FAN MOTOR| 1| 1| 1| 1| 1| 1| 1| MF| RC0J30- □□ ,
Includes FAN MOTOR RUBBER
MOUNT (2 PCS/SET)
17| U01 A01 333| MOTOR BAND| 1| 1| 1| 1| 1| 1| 1| |
18| U01 A03 302| LINE FLOW FAN| 1| 1| 1| 1| 1| 1| 1| |

MSZ-GS06NA MSZ-GS09NA MSZ-GS12NA MSZ-GS15NA MSY-GS09NA MSY-GS12NA MSY-GS15NA
1-4. INDOOR UNIT HEAT EXCHANGER

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 4

1-4. INDOOR UNIT HEAT EXCHANGER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS06NA – U1| MSZ-GS09NA – U1| MSZ-GS12NA – U1| MSZ-GS15NA – U1| MSY-GS09NA – U1| MSY-GS12NA – U1| MSY-GS15NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---|---|---|---
1| U01 A07 620| INDOOR HEAT EXCHANGER| 1| 1| 1| | 1| 1| | |
1| U01 A08 620| INDOOR HEAT EXCHANGER| | | | 1| | | 1| |
2| U01 A01 666| UNION GAS| 1| 1| 1| | 1| 1| | | ø3/8 (ø9.52)
2| U01 A02 666| UNION GAS| | | | 1| | | 1| | ø1/2 (ø12.7)
3| U01 A01 667| UNION LIQUID| 1| 1| 1| 1| 1| 1| 1| | ø1/4 (ø6.35)

MSZ-GS18NA MSY-GS18NA
1-5. INDOOR UNIT STRUCTURAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 5

1-6. ACCESSORY AND REMOTE CONTROLLER

1-5. INDOOR UNIT STRUCTURAL PARTS
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS18NA – U1| MSY-GS18NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---
1| E22 17A 234| BOX ASSEMBLY| 1| 1| |
2| E22 N87 976| CORNER BOX LEFT| 1| 1| |
3| E22 N94 000| PANEL ASSEMBLY| 1| 1| | Includes No. 4, 5, and 6
4| E22 F95 142| CATCH| 2| 2| | 2 PCS/SET
5| E22 913 067| SCREW CAP| 2| 2| | 2 PCS/SET
6| E22 N87 010| FRONT PANEL| 1| 1| |
7| E22 N94 100| AIR FILTER (NANO PLATINUM FILTER)| 2| 2| | 1 PC/SET
8| E22 N87 975| CORNER BOX RIGHT| 1| 1| |
9| E22 N87 970| INSTALLATION PLATE| 1| 1| |
10| | AIR CLEANING FILTER (ANTI-ALLERGY ENZYME FILTER)| 2| 2| | MAC-408FT-E 2 PCS/SET

1-6. ACCESSORY AND REMOTE CONTROLLER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS18NA – U1| MSY-GS18NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---
11| E22 13T 426| REMOTE CONTROLLER| 1| | | SH22C
11| E22 14T 426| REMOTE CONTROLLER| | 1| | SH22D
12| E22 41G 083| REMOTE CONTROLLER HOLDER| 1| 1| |

MSZ-GS18NA MSY-GS18NA
1-7. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 7

1-7. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.| Part No.| Part name| MSZ-GS18NA – U1| MSY-GS18NA – U1| Symbol in Wiring Diagram| Remarks [Drawing No.]
---|---|---|---|---|---|---
1| E22 A89 509| BEARING MOUNT ASSEMBLY| 1| 1| | Includes SLEEVE BEARING
2| E22 P72 702| DRAIN HOSE| 1| 1| |
3| —| DRAIN CAP| 1| 1| | [ SU26R611H01 ]
4| E22 13T 235| NOZZLE ASSEMBLY| 1| 1| | Full assembly except DRAIN HOSE
5| E22 N87 040| HORIZONTAL VANE| 1| 1| |
6| E22 N87 303| VANE MOTOR (HORIZONTAL)| 1| 1| MV1| UP & DOWN
7| E22 J44 303| VANE MOTOR (VERTICAL)| 1| 1| MV2| RIGHT & LEFT
8| E22 13T 375| TERMINAL BLOCK| 1| 1| TB|
9| E22 N87 095| CONTROL P.C. BOARD HOLDER ASSEMBLY| 1| 1| |
10| E22 13T 452| ELECTRONIC CONTROL P.C. BOARD| 1| | |
10| E22 14T 452| ELECTRONIC CONTROL P.C. BOARD| | 1| |
11| E22 N87 784| V.A. CLAMP| 1| 1| |
12| E22 N94 979| CONDUIT COVER| 1| 1| |
13| E22 N94 978| CONDUIT PLATE| 1| 1| |
14| E22 13T 308| ROOM TEMPERATURE THERMISTOR| 1| 1| RT11|
15| E22 K90 385| VARISTOR| 1| 1| NR11|
16| E22 C67 382| FUSE| 1| 1| F11| T3.15AL250V
17| E22 13T 440| POWER P.C. BOARD| 1| 1| |
18| E22 N87 307| INDOOR COIL THERMISTOR| 1| 1| RT12, RT13|
19| E22 N87 333| MOTOR BAND| 1| 1| |
20| E22 N87 541| WATER COVER| 1| 1| |
21| E22 18A 333| MOTOR BED| 1| 1| |
22| E22 29L 300| INDOOR FAN MOTOR| 1| 1| MF| RC0J30-  □□, Includes FAN MOTOR RUBBER MOUNT (2 PCS/SET)
23| E22 17A 302| LINE FLOW FAN| 1| 1| |
24| E22 61F 303| VERTICAL VANE MOTOR UNIT| 1| 1| | Includes MV2

MSZ-GS18NA MSY-GS18NA
1-8. INDOOR UNIT HEAT EXCHANGER

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 8

1-8. INDOOR UNIT HEAT EXCHANGER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS18NA – U1| MSY-GS18NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---
1| E22 13T 620| INDOOR HEAT EXCHANGER| 1| 1| |
2| E22 151 667| UNION (LIQUID)| 1| 1| | ø1/4 (ø6.35)
3| E22 179 667| UNION (GAS)| 1| 1| | ø1/2 (ø12.7)

MSZ-GS24NA MSY-GS24NA
1-9. INDOOR UNIT STRUCTURAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 9

1-10. ACCESSORY AND REMOTE CONTROLLER

1-9. INDOOR UNIT STRUCTURAL PARTS
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS24NA – U1| MSY-GS24NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---
1| E22 12A 234| BOX ASSEMBLY| 1| 1| |
2| E22 T16 000| PANEL ASSEMBLY| 1| 1| | Includes No. 3, 4, and 5
3| E22 408 142| CATCH| 4| 4| | 4 PCS/SET
4| E22 F28 067| SCREW CAP| 3| 3| | 3 PCS/SET
5| E22 R19 010| FRONT PANEL| 1| 1| |
6| E22 F28 100| AIR FILTER (NANO PLATINUM FILTER)| 2| 2| | 1 PC/SET
7| E22 F28 975| CORNER BOX (RIGHT)| 1| 1| |
8| E22 F28 976| CORNER BOX (LEFT)| 1| 1| |
9| E22 F28 970| INSTALLATION PLATE| 1| 1| |
10| | AIR CLEANING FILTER (ELECTROSTATIC ANTI-ALLERGY ENZYME FILTER)| 2| 2| | MAC-2310FT-E 2 PCS/SET

1-10. ACCESSORY AND REMOTE CONTROLLER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS24NA – U1| MSY-GS24NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---
11| E22 19T 426| REMOTE CONTROLLER| 1| | | SH22E
11| E22 20T 426| REMOTE CONTROLLER| | 1| | SH22F
12| E22 41G 083| REMOTE CONTROLLER HOLDER| 1| 1| |

MSZ-GS24NA MSY-GS24NA
1-11. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 11

1-11. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.| Part No.| Part name| MSZ-GS24NA – U1| MSY-GS24NA – U1| Symbol in Wiring Diagram| Remarks [Drawing No.]
---|---|---|---|---|---|---
1| E22 A89 509| BEARING MOUNT ASSEMBLY| 1| 1| | Includes SLEEVE BEARING
2| E22 T20 702| DRAIN HOSE| 1| 1| |
3| | DRAIN CAP| 1| 1| | [ SU26R611H01 ]
4| E22 19T 235| NOZZLE ASSEMBLY| 1| 1| | Full assembly except DRAIN HOSE
5| E22 F76 040| VANE (UPPER)| 1| 1| |
6| E22 F76 041| VANE (LOWER)| 1| 1| |
7| E22 C33 303| VANE MOTOR (HORIZONTAL)| 1| 1| MV1| UP & DOWN
8| E22 C32 303| VANE MOTOR (VERTICAL)| 2| 2| MV2| RIGHT & LEFT
9| E22 F28 541| WATER CUT| 1| 1| |
10| E22 45N 308| ROOM TEMPERATURE THERMISTOR| 1| 1| RT11|
11| E22 F76 979| CONDUIT COVER| 1| 1| |
12| E22 F76 978| CONDUIT PLATE| 1| 1| |
13| E22 77P 468| POWER MONITOR RECEIVER SWITCH P.C. BOARD| 1| 1| |
14| E22 F28 095| POWER MONITOR RECEIVER HOLDER| 1| 1| |
15| E22 19T 452| ELECTRONIC CONTROL P.C. BOARD| 1| | | Includes TERMINAL P.C. BOARD with TERMINAL BLOCK
15| E22 20T 452| ELECTRONIC CONTROL P.C. BOARD| | 1| | Includes TERMINAL P.C. BOARD with TERMINAL BLOCK
16| E22 F28 307| INDOOR COIL THERMISTOR| 1| 1| RT12, RT13|
17| E22 K90 385| VARISTOR| 1| 1| NR11|
18| E22 C67 382| FUSE| 1| 1| F11| T3.15AL250V
19| E22 F76 784| V.A. CLAMP| 1| 1| |
20| E22 90F 333| MOTOR BED| 1| 1| |
21| E22 F28 300| INDOOR FAN MOTOR| 1| 1| MF| RC0J56- □□ Includes FAN MOTOR RUBBER MOUNT (2 PCS/SET)
22| E22 89F 333| MOTOR BAND| 1| 1| |
23| E22 19A 302| LINE FLOW FAN| 1| 1| |
24| E22 82F 303| VERTICAL VANE MOTOR UNIT (L)| 1| 1| | Includes MV2
25| E22 84F 303| VERTICAL VANE MOTOR UNIT (R)| 1| 1| | Includes MV2

1-12. INDOOR UNIT HEAT EXCHANGER MSZ-GS24NA MSY-GS24NA

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 12

1-12. INDOOR UNIT HEAT EXCHANGER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part name| MSZ-GS24NA – U1| MSY-GS24NA – U1| Symbol in Wiring Diagram| Remarks
---|---|---|---|---|---|---
1| E22 19T 620| INDOOR HEAT EXCHANGER| 1| 1| |
2| E22 527 666| UNION (GAS)| 1| 1| | ø5/8 (ø15.88)
3| E22 151 667| UNION (LIQUID)| 1| 1| | ø1/4 (ø6.35)

MSZ-GS30NA MSZ-GS36NA MSY-GS30NA MSY-GS36NA
1-13. INDOOR UNIT STRUCTURAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 13

1-14. ACCESSORY AND REMOTE CONTROLLER

1-13. INDOOR UNIT STRUCTURAL PARTS
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part Name| MSZ-GS30NA – U1| MSZ-GS36NA – U1| MSY-GS30NA – U1| MSY-GS36NA – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
1| E22 C92 970| INSTALLATION PLATE| 1| 1| 1| 1| |
2| E22 45N 234| BOX ASSEMBLY| 1| 1| 1| 1| |
3| E22 45N 000| PANEL ASSEMBLY| 1| 1| 1| 1| | Includes No.4, 5, 6 and 7
4| E22 408 142| CATCH| 2| 2| 2| 2| | 2 PCS/SET
5| E22 C92 142| CATCH| 2| 2| 2| 2| | 2 PCS/SET
6| E22 55J 067| SCREW CAP| 3| 3| 3| 3| | 3 PCS/SET
7| E22 B04 010| FRONT PANEL| 1| 1| 1| 1| |
8| E22 45N 100| AIR FILTER (NANO PLATINUM FILTER)| 2| 2| 2| 2| | 1 PC/SET
9| E22 C92 975| CORNER BOX| 1| 1| 1| 1| |
10| —| AIR CLEANING FILTER (ANTI-ALLERGY ENZYME FILTER)| 2| 2| 2| 2| | 2 PCS/SET MAC-1415FT-E

1-14. ACCESSORY AND REMOTE CONTROLLER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part Name| MSZ-GS30NA – U1| MSZ-GS36NA – U1| MSY-GS30NA – U1| MSY-GS36NA – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
11| E22 45N 426| REMOTE CONTROLLER| 1| 1| | | | KM15H
11| E22 47N 426| REMOTE CONTROLLER| | | 1| 1| | KM15J
12| E22 527 083| REMOTE CONTROLLER HOLDER| 1| 1| 1| 1| |

1-15. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
MSZ-GS30NA MSZ-GS36NA MSY-GS30NA MSY-GS36NA

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 15

1-15. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part Name| MSZ-GS30NA – U1| MSZ-GS36NA – U1| MSY-GS30NA – U1| MSY-GS36NA – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
1| E22 55J 302| LINE FLOW FAN| 1| 1| 1| 1| |
2| E22 A89 509| BEARING MOUNT ASSEMBLY| 1| 1| 1| 1| |
3| E22 T20 702| DRAIN HOSE| 1| 1| 1| 1| |
4| E22 45N 235| NOZZLE ASSEMBLY| 1| 1| 1| 1| | Full assembly except DRAIN HOSE
5| E22 C92 040| VANE UPPER| 1| 1| 1| 1| |
6| E22 C92 041| VANE LOWER| 1| 1| 1| 1| |
7| E22 518 541| WATER COVER| 1| 1| 1| 1| |
8| E22 448 303| VANE MOTOR (VERTICAL)| 2| 2| 2| 2| MV2, MV3| RIGHT & LEFT
9| E22 73F 303| VANE MOTOR UNIT (L) (VERTICAL)| 1| 1| 1| 1| | Includes MV3
10| E22 77F 303| VANE MOTOR UNIT (R) (VERTICAL)| 1| 1| 1| 1| | Includes MV2
11| E22 749 303| VANE MOTOR (HORIZONTAL)| 1| 1| 1| 1| MV1| UP & DOWN
12| E22 55J 468| POWER MONITOR RECEIVER P.C. BOARD| 1| 1| 1| 1| |
13| E22 C92 095| POWER MONITOR RECEIVER HOLDER| 1| 1| 1| 1| |
14| E22 55J 782| SWITCH HOLDER| 1| 1| 1| 1| |
15| E22 73F 978| CONDUIT PLATE| 1| 1| 1| 1| |
16| E22 45N 308| ROOM TEMPERATURE THERMISTOR| 1| 1| 1| 1| RT11|
17| E22 45N 452| ELECTRONIC CONTROL P.C. BOARD| 1| | | | | Includes SW P.C. BOARD
17| E22 46N 452| ELECTRONIC CONTROL P.C. BOARD| | 1| | | | Includes SW P.C. BOARD
17| E22 47N 452| ELECTRONIC CONTROL P.C. BOARD| | | 1| | | Includes SW P.C. BOARD
17| E22 48N 452| ELECTRONIC CONTROL P.C. BOARD| | | | 1| | Includes SW P.C. BOARD
18| E22 55J 374| TERMINAL BLOCK| 1| 1| 1| 1| TB|
19| E22 C92 333| MOTOR BAND| 1| 1| 1| 1| |
20| E22 73F 784| V.A.CLAMP| 1| 1| 1| 1| |
21| E22 55J 300| INDOOR FAN MOTOR ASSEMBLY| 1| 1| 1| 1| MF| RC0J56- Includes FAN MOTOR RUBBER MOUNT (2 PCS/SET)
22| E22 B75 385| VARISTOR| 1| 1| 1| 1| NR11|
23| E22 42J 382| FUSE| 1| 1| 1| 1| F11| T3.15AL250V
24| E22 55J 333| MOTOR BED| 1| 1| 1| 1| |
25| E22 45N 307| INDOOR COIL THERMISTOR| 1| 1| 1| 1| RT12, RT13|

1-16. INDOOR UNIT HEAT EXCHANGER
MSZ-GS30NA MSZ-GS36NA MSY-GS30NA MSY-GS36NA

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 16

1-16. INDOOR UNIT HEAT EXCHANGER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part Name| MSZ-GS30NA – U1| MSZ-GS36NA – U1| MSY-GS30NA – U1| MSY-GS36NA – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
1| E22 45N 620| INDOOR HEAT EXCHANGER| 1| 1| 1| 1| | Full assembly except connect pipe
2| E22 151 667| UNION (LIQUID)| 1| 1| 1| 1| | ø1/4
3| E22 527 666| UNION (GAS)| 1| 1| 1| 1| | ø5/8

MSZ-GS30NA2 MSZ-GS36NA2 MSY-GS30NA2 MSY-GS36NA2
1-17. INDOOR UNIT STRUCTURAL PARTS

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 17

1-18. ACCESSORY AND REMOTE CONTROLLER

1-17. INDOOR UNIT STRUCTURAL PARTS
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part Name| MSZ-GS30NA2 – U1| MSZ-GS36NA2 – U1| MSY-GS30NA2 – U1| MSY-GS36NA2 – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
1| E22 C92 970| INSTALLATION PLATE| 1| 1| 1| 1| |
2| E22 45N 234| BOX ASSEMBLY| 1| 1| 1| 1| |
3| E22 45N 000| PANEL ASSEMBLY| 1| 1| 1| 1| | Includes No.4, 5, 6 and 7
4| E22 408 142| CATCH| 2| 2| 2| 2| | 2 PCS/SET
5| E22 C92 142| CATCH| 2| 2| 2| 2| | 2 PCS/SET
6| E22 55J 067| SCREW CAP| 3| 3| 3| 3| | 3 PCS/SET
7| E27 B04 010| FRONT PANEL| 1| 1| 1| 1| |
8| E22 45N 100| AIR FILTER (NANO PLATINUM FILTER)| 2| 2| 2| 2| | 1 PC/SET
9| E22 C92 975| CORNER BOX| 1| 1| 1| 1| |
10| —| AIR CLEANING FILTER (ANTI-ALLERGY ENZYME FILTER)| 2| 2| 2| 2| | 2 PCS/SET MAC-1415FT-E

1-18. ACCESSORY AND REMOTE CONTROLLER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part Name| MSZ-GS30NA2 – U1| MSZ-GS36NA2 – U1| MSY-GS30NA2 – U1| MSY-GS36NA2 – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
11| E22 19T 426| REMOTE CONTROLLER| 1| 1| | | | SH22E
11| E22 20T 426| REMOTE CONTROLLER| | | 1| 1| | SH22F
12| E22 41G 083| REMOTE CONTROLLER HOLDER| 1| 1| 1| 1| |

1-19. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS
MSZ-GS30NA2 MSZ-GS36NA2 MSY-GS30NA2 MSY-GS36NA2

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 19

1-19. INDOOR UNIT ELECTRICAL PARTS AND FUNCTIONAL PARTS

  1. The part quantity below indicates the required number of pieces per unit.
  2. The circled No. indicates that the part is not shown in the figure.

No.| Part No.| Part Name| MSZ-GS30NA2 – U1| MSZ-GS36NA2 – U1| MSY-GS30NA2 – U1| MSY-GS36NA2 – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
1| E22 55J 302| LINE FLOW FAN| 1| 1| 1| 1| |
2| E22 A89 509| BEARING MOUNT ASSEMBLY| 1| 1| 1| 1| |
3| E22 T20 702| DRAIN HOSE| 1| 1| 1| 1| |
4| E22 52V 235| NOZZLE ASSEMBLY| 1| 1| 1| 1| | Full assembly except DRAIN HOSE
5| E22 C92 040| VANE UPPER| 1| 1| 1| 1| |
6| E22 C92 041| VANE LOWER| 1| 1| 1| 1| |
7| E27 518 541| WATER COVER| 1| 1| 1| 1| |
8| E22 448 303| VANE MOTOR (VERTICAL)| 2| 2| 2| 2| MV2, MV3| RIGHT & LEFT
9| E22 73F 303| VANE MOTOR UNIT (L) (VERTICAL)| 1| 1| 1| 1| | Includes MV3
10| E22 77F 303| VANE MOTOR UNIT (R) (VERTICAL)| 1| 1| 1| 1| | Includes MV2
11| E22 749 303| VANE MOTOR (HORIZONTAL)| 1| 1| 1| 1| MV1| UP & DOWN
12| E22 55J 468| POWER MONITOR RECEIVER P.C. BOARD| 1| 1| 1| 1| |
13| E22 C92 095| POWER MONITOR RECEIVER HOLDER| 1| 1| 1| 1| |
14| E22 55J 782| SWITCH HOLDER| 1| 1| 1| 1| |
15| E22 73F 978| CONDUIT PLATE| 1| 1| 1| 1| |
16| E22 45N 308| ROOM TEMPERATURE THERMISTOR| 1| 1| 1| 1| RT11|
17| E22 52V 452| ELECTRONIC CONTROL P.C. BOARD| 1| | | | | Includes SW P.C. BOARD
17| E22 53V 452| ELECTRONIC CONTROL P.C. BOARD| | 1| | | | Includes SW P.C. BOARD
17| E22 54V 452| ELECTRONIC CONTROL P.C. BOARD| | | 1| | | Includes SW P.C. BOARD
17| E22 55V 452| ELECTRONIC CONTROL P.C. BOARD| | | | 1| | Includes SW P.C. BOARD
18| E22 52V 375| TERMINAL BLOCK| 1| 1| 1| 1| TB|
19| E22 C92 333| MOTOR BAND| 1| 1| 1| 1| |
20| E22 73F 784| V.A.CLAMP| 1| 1| 1| 1| |
21| E22 55J 300| INDOOR FAN MOTOR ASSEMBLY| 1| 1| 1| 1| MF| RC0J56- Includes FAN MOTOR RUBBER MOUNT (2 PCS/SET)
22| E22 K90 385| VARISTOR| 1| 1| 1| 1| NR11|
23| E22 C67 382| FUSE| 1| 1| 1| 1| F11| T3.15AL250V
24| E22 55J 333| MOTOR BED| 1| 1| 1| 1| |
25| E22 45N 307| INDOOR COIL THERMISTOR| 1| 1| 1| 1| RT12, RT13|
26| | DRAIN CAP| 1| 1| 1| 1| | [ SU26R611H01 ]

1-20. INDOOR UNIT HEAT EXCHANGER
MSZ-GS30NA2 MSZ-GS36NA2 MSY-GS30NA2 MSY-GS36NA2

MITSUBISHI ELECTRIC MSY-GS30NA-U1 Premier Cooling Only Wall Mounted Indoor
Unit - Fig 20

1-20. INDOOR UNIT HEAT EXCHANGER
1. The part quantity below indicates the required number of pieces per unit.

No.| Part No.| Part Name| MSZ-GS30NA2 – U1| MSZ-GS36NA2 – U1| MSY-GS30NA2 – U1| MSY-GS36NA2 – U1| Symbol In Wiring Diagram| Remarks
---|---|---|---|---|---|---|---|---
1| E22 52V 620| INDOOR HEAT EXCHANGER| 1| 1| 1| 1| | Full assembly except connect pipe
2| E22 151 667| UNION (LIQUID)| 1| 1| 1| 1| | ø1/4
3| E22 527 666| UNION (GAS)| 1| 1| 1| 1| | ø5/8

1-21. AIR CLEANING FILTER
Every 3 months:

  • Remove dirt by a vacuum cleaner.
    When dirt cannot be removed by vacuum cleaning:

  • Soak the filter and its frame in lukewarm water before rinsing it.

  • After washing, dry it well in shade.
    Every year:

  • Replace it with a new air cleaning filter for best performance.
    NOTE 1: Clean the filters regularly for best performance and to reduce power consumption.
    NOTE 2: Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold. It is therefore recommended to clean air filters every 2 weeks.

(ANTI-ALLERGY ENZYME FILTER)

Model Part No.

MSZ-GS06NA
MSZ-GS09NA
MSZ-GS12NA
MSZ-GS15NA
MSZ-GS18NA
MSY-GS09NA
MSY-GS12NA
MSY-GS15NA
MSY-GS18NA| MAC-408FT-E
MSZ-GS30NA
MSZ-GS36NA
MSY-GS30NA
MSY-GS36NA
MSZ-GS30NA2
MSZ-GS36NA2
MSY-GS30NA2
MSY-GS36NA2
| MAC-1415FT-E

MSZ-GS06/09/12/15/18NA
MSY-GS09/12/15/18NA

MSZ-GS30/36NA MSY-GS30/36NA MSZ-GS30/36NA2 MSY-GS30/36NA2

(ELECTROSTATIC ANTI-ALLERGY ENZYME FILTER)

Model Part No.

MSZ-GS24NA
MSY-GS24NA| MAC-2310FT-E

MSZ-GS24NA
MSY-GS24NA

OPTIONAL PARTS

2. AIR CLEANING FILTER (MICROPARTICLE CATCHING FILTER)
Every 3 months:

  • Remove dirt by a vacuum cleaner.

  • Do not wash it with water. Replace it with a new air cleaning filter when tobacco tar or oil stains adhere to it.

  • Put it back to its original position, and install all tabs of the air cleaning filter.
    Every 3 year:

  • Replace it with a new air cleaning filter for best performance.
    NOTE 1: Clean the filters regularly for best performance and to reduce power consumption.
    NOTE 2: Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold. It is therefore recommended to clean air filters every 2 weeks.

Air cleaning filter replacement

MSZ-GS06NA
MSZ-GS09NA
MSZ-GS12NA
MSZ-GS15NA
MSZ-GS18NA
MSY-GS09NA
MSY-GS12NA
MSY-GS15NA
MSY-GS18NA| MAC-EMF515FT-E
---|---
MSZ-GS24NA MSY-GS24NA| MAC-EMF615FT-E

MSZ-GS06/09/12/15/18NA
MSY-GS09/12/15/18NA

MSZ-GS24NA
MSY-GS24NA

HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
© Copyright 2021 MITSUBISHI ELECTRIC CORPORATION
Issued: Oct. 2022 No. OBB874 REVISED EDITION-A
Published: Jan. 2021. No. OBH874
Made in Japan
Specifications subject to change without notice.