EV Portable Charger
User Manual
P3PM2T2 Portable Charger
Enjoy it.
Please read this instruction carefully before using the product.
Please carefully read the following instructions before charging your
Electrical Vehicle, be aware of the hazards involved with electrical circuity
and standard practices for preventing accidents.
Introduction to the Portable EV Charger ( Mode 2 )
CAUTION
- Use the power source with external upstream Circuit Breaker.
- Make sure the charger is used in a safe, secure place and well out of the reach of young children or pets.
- Please use the charger in a dry, well ventilated and secure place. Keep weel out of reach of young children or pets. Avoid water pouring directly onto the power plug.
- Do not open the enclosure while charging or with the power on.
- Do not maliciously damage the product.
Introduction to the Portable EV Charger ( Mode 2 )
Specifications
Model| Power Supply Type| Cable Total Length| Voltage|
Current| Connector Type
---|---|---|---|---|---
P1 PM2T2| Single-phase| 8m| 220-250V| 8/10/13/16A| T2
P1 PM2T1| Single-phase| 8m| 220-250V| 8/10/13/16A| T1
P1 PM2T2C| Single-phase| 8m| 220-250V| 8/10/13/16A| T2
P3PM2T2| Three-phase| 8m| 380-450V| 8/10/13/16A| T2
P1 PM2T2BS| Single-phase| 8m| 220-250V| 8/10/13/16A| T2
P1 PM2T1 BS| Single-phase| 8m| 220-250V| 8/10/13/16A| T1
- Model: P3PM2T2 Explanation of the operating display**
| Power light
---|---
| Charge lamp
| Trouble lamp
| Current switch button
| Charging time
| Temperature
| Grounding
4θ5V| Voltage
θ.89 kw| Power
| Rated current
3.9A| Constant current
θ.θθ2kwh**| Electricity consumption
| Time function button
Control box: Technical Parameters
Dimensions (L x W x H) | 260x 100 x 72.5 mm |
---|---|
Weight | 3Phase: 3.35 kg |
Protection Degree ( Control box) | IP65 |
Operating Temperature | -30°C to +50°C |
- Model: P1PM2T2/P1PM2T1/ P1PM2T2BS/ P1PM2T1BS
- Explanation of the operating display**
| Power light
---|---
| Charge lamp
| Trouble lamp
| Current switch button
| Charging time
| Temperature
| Grounding
245V| Voltage
θ.89 kw| Power
| Rated current
3.9A| Constant current
θ.θθ2kwh**| Electricity consumption
| Time function button
Control box: Technical Parameters
Dimensions (L x W x H) | 260x 100 x 72.5 mm |
---|---|
Weight | 1 Phase: 2.65 kg |
Protection Degree ( Control box) | IP65 |
Operating Temperature | -30°C to +50°C |
Use of the charger – start charging
Start Charging
Step | Illustration | Operation |
---|---|---|
1. | Insert the plug into the correct power supply socket. | |
2. | Remove the protective cap and fully insert the charging connector into |
the EV charging port
3.| | Start charging
DANGER
Do not use the product if it appears to be damaged or the cable is broken.
Do not disassemble or assemble the connector and change the internal parts.
Do not clean the products using chemicals or cleaning the EV car while
charging.
Stop Charging
Step | Illustration | Operation |
---|---|---|
1. | Disconnect the plug from t power supply socket | |
2. | Disconnect the chargii connector from the EV car. | |
3. | Close the protective shell of EV charging port,then cover the protective |
cap of the charging connector.
4.| | Put the portable charger into the bag.
Display Light Status
Display Light Status
Indicator Light| Status| Indicator Light| Status|
Indicator Light| Status
---|---|---|---|---|---
| Off| | Blink| | On
| Off| | Blink| | On
| Off| | Blink| | On
Operation
1| Power Off| | |
---|---|---|---|---
2| Check| | |
3| Standby| | |
4| Connected| | |
5| Charging| | |
6| Charge Complete| | |
Troubleshooting:
1| CP Error| | |
---|---|---|---|---
2| Relay Error| | |
3| Over/Under Voltage| | |
4| Over current protection| | |
5| Electric leakage protection| | |
6| No ground connection| | |
7| Temperature warning| | |
8| Persistent high temperature| | |
Single Phase use:
The portable charger will work if used via an adapter from a single-phase
wall socket. If using an adapter, please make sure it is suitable for EV
charging — approved for minimum 16A.
If the charger is connected to a single-phase wall socket via an adapter, it
is important to make sure the wall socket is suitable for EV charging —
approved for minimum 16A.
If used via an adapter in a wall socket with ground connection the functions
of the portable charger are identical to three phase use.
If used via an adapter in a wall socket without ground connection, press
“AMPS’and “TIME”for two seconds after firmly connecting the portable charger
to the wall socket The portable charger should not be connected to the vehicle
at this stage.
No ground connection| | |
---|---|---|---
After pressing “AMPS and “TIME” for 2 seconds insert the charging connector
into the electric vehicle.
switch the power from the wall socket off and on again.
Now the portable charger will be able to charge without a ground connection.
Please note that many Electric Vehicles require ground connection to start the
charging process.
Function: Switch Current
Switch Current:
CAUTION
In order to switch charging current,Please make sure the power plug is
firmly inserted into the socket and plug for the EV vehicle is disconnected.
Step | Statu | |
---|---|---|
1.Insert the plug into the correct power supply socket. | Ready | |
2.Press thesAmpsa switch button for 2 seconds | Enter setting the switch |
current mode
3.Continue to press the button briefly.The current will be changed.
(switch between 8-10-13-16A )| | Setting the current of User’s request
4.Press the button for 2s again.| | Setting successfully
Please complete setting within 4 seconds at each step, otherwise the feature
setting will fail.
Timer function:
CAUTION
In order to switch charging current,Please make sure the power plug is
firmly inserted into the socket and the plug for EV vehicle is disconnected.d
Step | Statu | |
---|---|---|
1. Insert the plug into the correct power supply socket | Ready | |
2. Press thealimes switch button for 2 seconds | Enter setting the delay |
time mode
3. Continue to press the button briefly.The time will be changed.
(Switch between 1/2/4/6/8/10H)| | Setting the delay time of User’ s request
4. Press the button for 2s again| | Setting successfully
Please complete setting within 4 seconds at each step, otherwise the feature
setting will fail.
Notice:
In case you want to cancel the timer setting – you can use one of the two
options below:
- Directly to disconnect the plug from the outlet socket.
- Press the Time button for 5s.
EVSE
Info@blaupunkt-ev.com
BLP EV Systems ApS
Ediths Alle 8
5250 Odense SV
Denmark
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>