| a = 0°| a = 30°| a = 45°| a = 70°| a = 90°
---|---|---|---|---|---
S(m2)| CxS
(m2)| EPA
(ft2)| S(m2)| CxS
(m2)| EPA
(ft2)| S(m
S(m2)| CxS
(m2)| EPA
(ft2)| S(m
S(m2)| CxS
(m2)| EPA
(ft2)| S(m2)| CxS
(m2)| EPA
(ft2)
$1| 0.0633| 0.08| 0.82| 0.1718| 0.21| 2.| 0.2253| 0.28| 3.| 0.2815| 0.34| 4.| 0.2915| 0.35| 4.
$2| 0.2915| 0.35| 4.| 0.2764| 0.34| 4.| 0.2428| 0.3| 3.| 0.1530| 0.19| 2.| 0.0633| 0.08| 0.82
S3| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81

MOUNTING

Schreder Briteline Gen2 2 External Version - MOUNTING Screws and washers are not included in the package!

Minimum screw requirement:

Vibration standard IEC 0.5g / ANSI 1.5g
Minimum fastener requirement lx M20 8.8 or A2-70 DIN9021 large plain washer
Tightening torques 1xM20: 200 Nm 2xM20: 140 Nm

Recommended to use anti-seizing agent (Tikal Tef-Gel®) !
1 1xM20 with extra large washer or
2 2xM20 with extra large washer

Mounting dimensions

D1 D2 D3 D4 D5 D6

min 250mm
min 9.84in| 70mm
2.75in| 150mm
5.9in| 320mm
12,6in| 460mm
15.98in| 22mm
0.86in

Schreder Briteline Gen2 2 External Version - MOUNTING
3

Minimum Surface Contact Area for screw fixation 124mm/4.88in

Schreder Briteline Gen2 2 External Version - MOUNTING
4

Fasteners are not included in the package!
Remark: the hatched area always need to be supported by a flat planar mounting surface as minimum. Wider surface contact is recommended, smaller is not allowed!

Schreder Briteline Gen2 2 External Version - MOUNTING
5

Schreder Briteline Gen2 2 External Version - MOUNTING
6

Schreder Briteline Gen2 2 External Version - MOUNTING
7![Schreder Briteline Gen2 2 External Version

Cable ID Connection Cable gland Suitable cable 0
A Mains input M20  06-10mm or

010-14mm
B| Mains re-launch
C| DC output to optical block| M25/cable protection compatibility| 06-10mm or
010-14mm
D| Dimming input| M16| 04.5-7.5mm or
07.5-10.5mm
E| Dimming re-launch

Cable types and cable gland
When using a larger external diameter cable, the plug and the smaller inner diameter seal need to be removed. When using a smaller external diameter cable, simply remove the plug.

Schreder Briteline Gen2 2 External Version - MOUNTING
10

Schreder Briteline Gen2 2 External Version - Cable gland
shell

Make electrical connection
Schreder Briteline Gen2 2 External Version - Cable gland shell
1

Connection Cable gland Recommended cable type
Control signal PG16(05-07.5/07.5-010) HO5RN-F, 2 x 1-1.5mm2
AC INPUT PG20(06-010/010-014) HO7RN-F, 3 x 1.5-4mm=
DC OUTPUT PG20(06-010/010-014) HO5RN-F, 5 x 1.0mm= HO7RN-F, 5 x 1.5mm=

Schreder Briteline Gen2 2 External Version - Cable gland shell
2

Close the cover of the junction box and gear box, and put the R-type buckles back on both.
Use metal tubes to protect the cables connected to the junction box.

RECOMMENDATIONS

Schreder Briteline Gen2 2 External Version - Cable gland shell
3

At least 1 meter distance should be kept from surrounding walls, floor, and ceiling for all types of mounting/inclination.

Product Driver MCB B type
B10 B13 B16
BRITELINE GEN2 2 @220V EUM-680MG/BG 0
BRITELINE GEN2 2 @480V ESM-680MG/BG 1
Product Driver MCB C type
10 13 16
BRITELINE GEN2 2 @220V EUM-680MG/BG 0
BRITELINE GEN2 2 @480V ESM-680MG/BG 1

Schreder Briteline Gen2 2 External Version - Cable gland shell
4

The small blocks on the side of the optical block assure the installation of the built-in aiming devide. The external aiming device position 1 needs to be aligned with positions 2 and 3

Schreder Briteline Gen2 2 External Version - Cable gland shell
5

SAFETY INSTRUCTIONS

The light source contained in this luminaire shall only be replaced by the manufacturer orhis service agent or a similar qualified person. Always switch off the power prior to installation, maintenance or repair activities. ENG RISK GROUP 2 – CAUTION!  azardous opticalradiation may be emitted from this product. Do not stare at the luminaire when operating as it may be harmful to the eyes. The luminaire should be positioned so that prolonged staring at the luminaire at a distance of less than 0.2m is not expected. This product contains a light source of an energy efficiency class G or higher. In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE cable is protected against climatic conditions, especially UV rays and rain, by making sure that the cable is contained inside the luminaire and pole Y-connection: In case of damage to the wire, it has to be replaced only by the manufacturerdistributor or by an expert, to avoid risks.

Schreder Briteline Gen2 2 External Version - Icon 3

Copyright © Schréder S.A. 2023 – Executive Publisher:
Stéphane Halleux – B-4000 Liége, Rue de Mons 3 (Belgium)
The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
Rev B | 07-2023

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Schreder User Manuals

Related Manuals