Schreder Briteline Gen2 2 External Version Instruction Manual
- June 12, 2024
- Schreder
Table of Contents
BRITELINE
GEN2 2
External version INSTALLATION INSTRUCTIONS
Briteline Gen2 2 External Version
| a = 0°| a = 30°| a = 45°| a = 70°| a = 90°
---|---|---|---|---|---
S(m2)| CxS
(m2)| EPA
(ft2)| S(m2)| CxS
(m2)| EPA
(ft2)| S(m
S(m2)| CxS
(m2)| EPA
(ft2)| S(m
S(m2)| CxS
(m2)| EPA
(ft2)| S(m2)| CxS
(m2)| EPA
(ft2)
$1| 0.0633| 0.08| 0.82| 0.1718| 0.21| 2.| 0.2253| 0.28| 3.| 0.2815| 0.34| 4.|
0.2915| 0.35| 4.
$2| 0.2915| 0.35| 4.| 0.2764| 0.34| 4.| 0.2428| 0.3| 3.| 0.1530| 0.19| 2.|
0.0633| 0.08| 0.82
S3| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08| 0.81| 0.0625| 0.08|
0.81| 0.0625| 0.08| 0.81
MOUNTING
Screws and washers are not included in the package!
Minimum screw requirement:
Vibration standard | IEC 0.5g / ANSI 1.5g |
---|---|
Minimum fastener requirement | lx M20 8.8 or A2-70 DIN9021 large plain washer |
Tightening torques | 1xM20: 200 Nm 2xM20: 140 Nm |
Recommended to use anti-seizing agent (Tikal Tef-Gel®) !
1 1xM20 with extra large washer or
2 2xM20 with extra large washer
Mounting dimensions
D1 | D2 | D3 | D4 | D5 | D6 |
---|
min 250mm
min 9.84in| 70mm
2.75in| 150mm
5.9in| 320mm
12,6in| 460mm
15.98in| 22mm
0.86in
Minimum Surface Contact Area for screw fixation 124mm/4.88in
Fasteners are not included in the package!
Remark: the hatched area always need to be supported by a flat planar mounting
surface as minimum. Wider surface contact is recommended, smaller is not
allowed!
![Schreder Briteline Gen2 2 External Version
- MOUNTING 8](https://manuals.plus/wp-content/uploads/2023/07/Schreder- Briteline-Gen2-2-External-Version-MOUNTING-8.png)
Cable ID | Connection | Cable gland | Suitable cable 0 |
---|---|---|---|
A | Mains input | M20 | 06-10mm or |
010-14mm
B| Mains re-launch
C| DC output to optical block| M25/cable protection compatibility| 06-10mm or
010-14mm
D| Dimming input| M16| 04.5-7.5mm or
07.5-10.5mm
E| Dimming re-launch
Cable types and cable gland
When using a larger external diameter cable, the plug and the smaller inner
diameter seal need to be removed. When using a smaller external diameter
cable, simply remove the plug.
Make electrical connection
Connection | Cable gland | Recommended cable type |
---|---|---|
Control signal | PG16(05-07.5/07.5-010) | HO5RN-F, 2 x 1-1.5mm2 |
AC INPUT | PG20(06-010/010-014) | HO7RN-F, 3 x 1.5-4mm= |
DC OUTPUT | PG20(06-010/010-014) | HO5RN-F, 5 x 1.0mm= HO7RN-F, 5 x 1.5mm= |
Close the cover of the junction box and gear box, and put the R-type buckles
back on both.
Use metal tubes to protect the cables connected to the junction box.
RECOMMENDATIONS
At least 1 meter distance should be kept from surrounding walls, floor, and ceiling for all types of mounting/inclination.
Product | Driver | MCB B type |
---|---|---|
B10 | B13 | B16 |
BRITELINE GEN2 2 @220V | EUM-680MG/BG | 0 |
BRITELINE GEN2 2 @480V | ESM-680MG/BG | 1 |
Product | Driver | MCB C type |
10 | 13 | 16 |
BRITELINE GEN2 2 @220V | EUM-680MG/BG | 0 |
BRITELINE GEN2 2 @480V | ESM-680MG/BG | 1 |
The small blocks on the side of the optical block assure the installation of the built-in aiming devide. The external aiming device position 1 needs to be aligned with positions 2 and 3
SAFETY INSTRUCTIONS
The light source contained in this luminaire shall only be replaced by the manufacturer orhis service agent or a similar qualified person. Always switch off the power prior to installation, maintenance or repair activities. ENG RISK GROUP 2 – CAUTION! azardous opticalradiation may be emitted from this product. Do not stare at the luminaire when operating as it may be harmful to the eyes. The luminaire should be positioned so that prolonged staring at the luminaire at a distance of less than 0.2m is not expected. This product contains a light source of an energy efficiency class G or higher. In case of PVC insulated mains cable, the installer MUST ensure that the WHOLE cable is protected against climatic conditions, especially UV rays and rain, by making sure that the cable is contained inside the luminaire and pole Y-connection: In case of damage to the wire, it has to be replaced only by the manufacturerdistributor or by an expert, to avoid risks.
Copyright © Schréder S.A. 2023 – Executive Publisher:
Stéphane Halleux – B-4000 Liége, Rue de Mons 3 (Belgium)
The information, descriptions and illustrations herein are only of an
indicative nature and subject to changes without notice.
www.schreder.com
Rev B | 07-2023