BOT-R6X Wireless Gas Boiler Thermostat
User Manual
Application
Intelligent digital thermostat is a temperature controller suitable for floor heating systems. Through comparing ambient temperature and set temperature, it controls the working state of the electric valve of the floor heating system to adjust the ambient temperature, which is comfort and energy saving.
Operating instructions
ON/OFF key: Press the ON/OFF key to turn on and off once; Press shutdown again
while closing all valves.
M Mode switch key: In the power-on state, press M to switch the working
mode. The LCD indicates the manual mode and the display indicates the
automatic mode.
Regulation key: In the power-on state, press to adjust the set
temperature and other parameters.
Clock adjustment: In the power-on state, press and hold the M key for 5
seconds, pressA after the icon flashes to adjust, and press the M key to
switch the time and adjust the week. Press the key to save and exit
Lock key function: In the boot state, press and hold and in the panel to
enter the lock key state for 5 seconds, and the lock icon appears on the
display’s right side, indicating that the lock key is successful
Low temperature protection function
Advanced options enter the third option ON, the thermostat is in the shutdown state, when the indoor temperature is lower than 5 degrees, the thermostat automatically turns on heating, when the indoor temperature rises to 5 degrees, the thermostat automatically turns off heating.
Electrical
specification
- Temperature sensor: NTC
- Temperature accuracy: ±1°C
- Self-consumed power: <170u W
- Voltage: Three 1.5V batteries
- Load current: 3A (Resistive)
- Protection grade:
Wiring diagram
Zero | Fire | Pump | kl | K2 | Normal’s open | Normally close |
---|
Remark: K1 K2 is a passive linkage of wa!l-hung furnaces
Normally Open: Motorized valve remain open
Normal Close: Motorized valve remain close
Notes: Since some circuits of this product involve strong electricity,
which need to be installed by professionals.
Launch panel
receiving panel
Code matching key Output indicator lamp Code matching indicator Power indicato
Code matching process:
- Power on the receiving panel, the power indicator is long on, Press and hold the code matching button, and the code matching indicator flashes.
- install 3 No. 5 batteries on the launch panel, and press the key long after booting. When the code matching indicator on the receiving panel is normally on, the code matching is successful.
Programming mode operation
- In the boot state, press and hold the M and Y keys for S seconds to enter the programming mode, and press M to switch parameters after entering the programming mode. In the first period after entering the programming mode, adjust the hour of time, press M to adjust the minute and then press M to adjust the temperature, the following periods of adjustment method is the same as the first period. Press ¢) to exit.
Key| Option| | Icon| Time| Adjustment time|
Default value| Adjust temperatur e
---|---|---|---|---|---|---|---
M| Workday| 1| | 6:00| .| 20ºC|
2| | 8:00| | 16ºC
3| | 11:30|
| 16ºC
4| | 12:30| 16ºC
5| | 17:00| 22ºC
6| | 22:00| 16ºC
Day of| 1| | 8:00| 22ºC
2| | 23:00| 16ºC
Parameter setting
In the shutdown state, simultaneously press M andV for 5 seconds to enter the parameter setting interface, press M to cycle to select the parameters to be set, and press the A V key to adjust the parameters. Press 0 to exit. The parameter breakdown is as follows:
Parameter item| Parameter name| Default value| Functional
meaning
---|---|---|---
1| Temperature compensation| 0| The temperature compensation range: -9.9-9.9°C
2| Switch deviation setting| 1| The temperature difference start-up range is
0.5-9.5°C
3| The shutdown antifreeze function starts and stops| 0FF| OFF: Turn off the
antifreeze function ON: Turn on anti-freezing function
4| Rest day selection| 2| 0: Without rest 01: single-day weekend 02: Double
Dayoff
5| Set the upper limit of the temperature| 60°C| Set the upper temperature
range from 35-95°C
6| Restore factory settings| | Long press, for 3seconds, display to restore
factory settings
Installation method
- Install an expansion screw sleeve with a spacing of 59mm on the wall
- Use a screwdriver to separate the upper cover and the lower cover, pursuant to the wire direction, pass the wire through the back cover to the wiring duct, and leave about 20cm long as per the actual situation
- Fix the bottom shell to the wall, and finally fix the wire, and cover the front shell on the bottom shell
Inspection steps
Install the intelligent touch screen thermostat in a place where it is easy for the user to view the screen and adjust the temperature set point. And the thermostat is located in a place that can represent the overall ambient temperature of the room. Avoid installing the thermostat near hot and cold sources, such as vents, heaters, outdoors or in places where
Common faults handling
Phenomena | Solutions |
---|---|
Don’t start up | 1. Check whether the battery is installed backwards 2. |
Inspect whether the boot key is valid
LCD displays messy code| Whether the rear shell installation is deformed, it
can be loosened and reinstalled
Display is normal, but there is no output| 1.Check whether the boundary
between the main control board and the power board is damaged
2.Check whether the output is connected to the wrong wire
Temperature displays error| Calibrate the panel temperature display via the
first item of advanced options
BOT-R6W Wired Gas Boiler Thermostat
Apply
Intelligent digital thermostat is a temperature controller,which suitable for
the floor heating system. Through the comparison of the ambient temperature
and the set temperature,the working state of the electric valve of the floor
heating system is controlled in order to adjust the ambient temperature,
comfort and energy-saving.
Operation instruction
Turn on / off key press the switch key to turn on once; press to shut down
again and close all valves at the same time.
M mode conversion key in the power-on state, press M to switch the working
mode, The liquld crystal display represents the manual mode and the display
represents the automatic mode.
When the adjustment key is turned on,press adjustment of the number Clock
adjustment:in the power-on state,press the M key for 5 seconds,press the Mkey
to switch the time and week after the icon flashes.press power or to save exit
Lock button function:long press in boot state and 5 seconds panel enter lock
kay state right side of display screen.the icon of the lock indicates that the
lock key was successful.
Cryogenic protection function Advanced options enter the third option,select
ON,the thermostat is turned off,when the room temperature is below 5 The
thermostat automatically turns on heating,and when the indoortemperature rises
to 5 degrees,the hermostat automatically turns off the heating
Electrical specification
- Temperature sensor NTC
- Temperature precision: ±1°
- Self-consumed:<170uW
- Voltage:three 1.5V batteries
- Load current:3A (negative)
- Protection grade:H20
Wiring diagram
Note:Passive linkage of wall-mounted furnace com and no
Note:due to the strong power design of some circuits of this product it
needs to be installed by professionals.
Programming mode operation
In the case of power on,press M and key for 5 seconds to enter programming
mode,then press M to switch parameters. the first time to enter the
programming mode is to adjust the hour of time,press M to adjust for
minutes,and then press M to adjust the temperature.The adjustment method of
each period is the same as that of the first period.press exit.
Key| Option| | Icon| Time| Adjustment time|
Default value| Adjust temperature
---|---|---|---|---|---|---|---
M| Workday| 1| | 6:00| .| 20ºC|
2| | 8:00| | 16ºC
3| | 11:30|
| 16ºC
4| | 12:30| 16ºC
5| | 17:00| 22ºC
6| | 22:00| 16ºC
Day of| 1| | 8:00| 22ºC
2| | 23:00| 16ºC
Parameters setting
In the shutdown state,press M and for 5 seconds at the same time to enter the parameter setting interface,at this time: press M cycle to select the parameters you need to set, and press key to adjust the parameters.Press chase out. The schedule of parameters is as follows:
Parameter item| Parameter name| The Default value|
Functional meaning
---|---|---|---
1| Temperature compensation| 0| The temperature compensation range: -9.9-9.9°C
2| Switch deviation setting| 1| The temperature difference start-up range is
0.5-9.5°C
3| The shutdown antifreeze function starts and stops| 0FF| OFF: Turn off the
antifreeze function ON: Turn on anti-freezing function
4| Rest day selection| 2| 0: Without rest 01: single-day weekend 02: Double
Dayoff
5| Set the upper limit of the temperature| 60°C| Set the upper temperature
range from 35-95°C
6| Restore factory settings| | Long press, for 3seconds, display to restore
factory settings
Installation method
- Install expansion screw sleeve with pitch 59mm on the wall.
- Separate the upper cover and the lower cover with a screwdriver,according to the direction of the alignment. The wire passes through the back cover to the slot and leaves about 20cm long according to the actual situation
- Fix the bottom shell to the wal,and finally fix the wire.Cover the front shell on the bottom shell. ****
Check step
The intelligent touch screen thermostat is installed where it is easy for the
user to watch the screen and adjust the temperature setting point.And make the
thermostat located in a place that can represent the overall ambent
temperature of the room.Avoid installing thermostats near cold and heat
sources,such as vents,heaters,outdoors or places where the sun shine.
Common failure
phenomenon | Treatment method |
---|---|
Cant not turn it on | 1.Check whether the battery is installed upside down |
2.Check whether the boot button is valid
LCD garbled code| Whether the rear shell installation is deformed, it can be
loosened and reinstalled.
Show normal and no output| 1.Check whether the connection between the main
control board and the power board is damaged
2.Check if the output has the wrong connection.
There is an error in the temperature| Display through the first calibration
panel of the advanced option.