Panasonic C811LH420 Whisper Choice DC with LED light and Humidity Sensor Instruction Manual
- June 12, 2024
- Panasonic
Table of Contents
- C811LH420 Whisper Choice DC with LED light and Humidity Sensor
- GENERAL SAFETY INFORMATION
- DESCRIPTION
- UNPACKING
- SUPPLIED ACCESORIES
- DIMENSIONS
- WIRING DIAGRAM
- SELECTOR INDICATOR
- OPERATION
- FEATURES
- INSTALLATION (RETROFIT)
- INSTALLATION (NEW CONSTRUCTION)
- MAINTENANCE (CLEANING)
- PRACTICAL GUIDE TO INSTALLATION
- SPECIFICATIONS
- PRODUCT SERVICE
- Documents / Resources
INSTALLATION INSTRUCTIONS
Ventilating Fan
Model No. RG-C811LHA
C811LH420 Whisper Choice DC with LED light and Humidity Sensor
READ AND SAVE THESE INSTRUCTIONS
Thank you for purchasing this Panasonic product. Please read these
instructions carefully before attempting to install, operate or service the
Panasonic product. Please carefully read the “GENERAL SAFETY INFORMATION”.
Failure to comply with instructions could result in personal injury or
property damage. Please explain to users how to operate and maintain the
product after installation and this manual should be presented to users.
Please retain this manual for future references.
GENERAL SAFETY INFORMATION
For Your Safety
To reduce the risk of injury, loss of life, electric shock, fire, malfunction,
and damage to equipment or property, always observe the following safety
precautions.
Explanation of symbol word panels
The following symbol word panels are used to classify and describe the level
of hazard, injury, and property damage caused when the denotation is
disregarded and improper use is performed.
WARNING Denotes a potential hazard that could result in serious injury or
death.
CAUTION Denotes a hazard that could result in minor injury.
NOTICE Denotes a hazard that could result in property damage.
** The following symbols are used to classify and describe the type of
instructions to be observed.
This symbol is used to alert users to a specific operating procedure that must
be followed in order to operate this unit safely.
This symbol is used to alert users to a specific operating procedure that must
not be performed.
This symbol is used to alert users not to disassemble the equipment.
This symbol is used to alert users to make sure of grounding when using the
equipment with the grounding terminal.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have any
questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off at service panel and lock
the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-rated
construction.
Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and safety standards such as
those published by the National Fire Protection Association (NFPA), and the
American Society of Heating, Refrigerating and Air-Conditioning Engineers
(ASHRAE) and the local code
authorities. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
Ducted exhaust fans must always be vented to the outdoors.
These models are UL listed for tub and shower enclosures.
If this product is no longer to be used, it must be removed from the ceiling
to prevent it from falling.
The ceiling joist must be able to withstand a static load of at least five
times the weight of the product.
If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application and be conneced to a GFCI (Ground Fault
Circuit Interrupter) – protected branch circuit.
To reduce the risk of fire, electric shock or injury to persons, do not use
replacement parts that have not been recommended by the manufacturer (eg.
parts made at home using a 3D printer).
This product must be properly grounded.
Do not install with a method which is not approved in the instructions.
Do not use this fan with any solid-state speed control device. Solid state
controls may cause harmonic distortion which can cause a humming noise in the
motor.
Not to be installed in a ceiling thermally insulated to a value greater than
R60.
Do not disassemble the unit for reconstruction. It may cause fire or electric
shock.
CAUTION
Follow all local electrical and safety codes, as well as the National
Electrical Code (NEC) and the Occupational Safety and Health Administration
(OSHA).
Make sure that the electric service supply voltage is AC 120 V 60 Hz.
Always disconnect the power source before working on or near the fan, motor,
light fixture or junction box.
Protect the supply wiring from sharp edges, oil, grease, hot surfaces,
chemicals or other objects.
The special-purpose or dedicated parts, such as mounting fixtures, must be
used if such parts are provided.
Please wear gloves to protect hands during installation.
Do not install this ventilating fan in a location where the interior room
temperature may exceed 104 °F (40 °C).
For general ventilating use only. Do not use to exhaust hazardous or explosive
materials and vapors.
Do not kink the supply wiring.
Do not install fan above or inside a 45-degree angle projected outwards from
the cooking equipment element closest to the fan. (Fig. A) NOTICE**
Provide make up air for proper ventilation.
Do not connect multiple units in parallel. If two or more units are connected
to one switch in parallel, the units may not function.
Do not install the unit where ducts are configured as shown in below:
DESCRIPTION
These products are listed by UL under UL file No. E78414.
These products use a sirocco fan driven by a DC motor powered by an Integral
transformer. The motor Is designed to have a long operating life, high dynamic
response, higher speed ranges and saving energy. The grille covering the fan
body is a spring-loaded, quick removal type. A damper for preventing air
counter flow is provided. The blower uses a high-capacity sirocco fan
developed to reduce the noise level. The lighting unit is an energy-saving LED
lighting device that uses one 10 W LED lamp and produces almost the same
illumination as a standard 40 W incandescent lamp. Night light feature
consumes around 0.1 to 0.4 W.
This Panasonic ventilating fan model is equipped with a humidity sensor that
tums the fan on automatically when humidity increases rapidly, or when
humidity rises above a 30% – 80% relative humidity set-point.
FCC Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 158 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
Interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning this product on and off, the user Is encouraged to try to correct the
interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect equipment into outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: This equipment must be installed by a qualified person in
accordance with the provided installation instructions; and all applicable
codes and standards. Also, any changes or modifications not expressly approved
by the party responsible for compliance could void the users authority to
operate this equipment.
SDoC Responsible Party: Panasonic Corporation of North America Two Riverfront
Plaza, Newark, NJ 07102
Customer Call Center: 1-866-292-7299
This device complies with Part 15B of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Type IC-Inherently Protected.
UNPACKING
Unpack and carefully remove the unit from carton. Refer to the Supplied Accessories list to verify that all parts are present.
SUPPLIED ACCESORIES
Part name| Appearance|
---|---|---
Grille| | 1
Flex-Z Fast'” bracket (with 4 tapping screws – ST4.2X20)| | 1
Installati Instructions ns/ Warranty sheet| | 1
Self- drilling screw| | 4
DIMENSIONS
Units:inches (mm)
No. | Part name | No. | Part name |
---|---|---|---|
1 | Blade | 7 | LED Lamp |
2 | 2SBladeGrille | 8 | Fan body |
3 | Junction box | 9 | Damper |
4 | Adaptor | 10 | Flex-Z FastTM bracket |
5 | PCB box | 11 | Selector |
6 | Pick-A-FIowTM switch | 12 | Humidity sensor |
WIRING DIAGRAM
SELECTOR INDICATOR
Humidity Sector range from around 30% to 80%.
Factory setting is around 50%. Timer preset selector positions
Timer [min] | 0.5 | 1 | 2 | 3 | 5 | 10 | 20 | 30 | 60 |
---|
Factory setting : 20 minutes.
Position : For factory use
OPERATION
*1 The product will continue to run for about 20 minutes
after the sensor detects that the humidity is -5 % RH lower than the humidity
setting before stopping.
Note:
- The power switch should be left on at all times.
- The product will also run when the humidity rises rapidly but does not reach the humidity trigger setting, and then stop after the time delay.
- The activation humidity settings on the dial are continuous from 30 %RH – 80 %RH.
- The humidity detected by the sensor may differ from the value on your hygrometer.
- The product may cycle on and off if the humidity is constantly near the trigger point. This can be addressed by raising the humidity trigger setting on the dial.
- The fan will run for 20 minutes when power switch is first turned on, regardless of the humidity sensor settings. After 20 minutes, the fan will retum to sensor mode.
FEATURES
These products employ innovative, state-of-the-art technologies that provide a
number of customizable unique features that lead to improved indoor air
quality. Please read this manual first in order to realize the benefits of
this customizable, modular fan.
Outstanding Energy Savings:
These products are built using DC motor technology. The DC motor is 30% – 70%
more energy efficient than the minimum ENERGY STAR requirements. Pick-A-FlowTM
Feature:
This product comes with Pick-A-FIowTM speed options. The Pick-A-Flow TIA
switch on the face of the product allows the option to choose 80 or 110 CFM.
This product can run continuously or intermittently, depending upon the needs
of the owner.
Air volume (CFM) | Factory setting |
---|---|
80 | 80 CFM |
INSTALLATION (RETROFIT)
IMPORTANT: Remove the tape placed on the damper and adaptor before
installation. Failure to do so will cause the product to work inefficiently
and create a loud noise.
WARNING
Disconnect power supply before installing the unit.
Please wear gloves to protect hands during the Installation.
-
Remove adaptor from fan body
1.Disconnect plug connector from the receptacle and remove adaptor from fan body by removin the machine screw (M4x8) before Installation. -
Remove existing fan
1. Remove the existing fan and cut the ceiling opening according to the required dimensions. -
Install Flex-Z FastTM bracket
Flex-Z Fast”‘ bracket position can be adjusted from 16′ to 24’ (406mm to 610mm) between joists. 1. Insert Flex-Z Faze’ bracket into the opening and extend.
2. Align and install bracket to joist by usig 2-prenstalled tapping screws.
3. Extend bracket to the other joist.
4. Install bracket to joist by using 2-preinstalled tapping screws. -
Insert circular exhaust duct 1. Remove screw from junction box cover to remove the knock-out hole and secure conduit or stress relief to Junction box knock-out hole.
2. Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved fool tape. A4 or 6 Inch circular duct is needed to connect to the relevant part of the adaptor.
3. Refer to WIRING DIAGRAM (Page 5). Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Use UL approved walk nuts to connect fan wires. After connecting wires. replace junction box cover.
4. Install the adaptor to Flex-Z Fast”a bracket by using 2 self-drilling screws. -
Install and secure fan body 1. Insert fan body and slide into adaptor assembly until the flange overlaps the Flex-Z Fast,” bracket.
2. Secure the fan body to Flex-Z Fast,” bracket by using 2 self-drilling screws.
3. Plug connector into weaved, and secure fan body to adaptor by using machine screw (M4X6).
CAUTION
Please take care when installing the machine screw (Step 5) to avoid moss threading and to ensure that the screw does not strip or tome in contact with Flex-Z Fast”‘ bracket. -
Sealing
1. Once fan body is mounted and secure, fill gap between flange and ceiling with caulk or other sealant to prevent air leakage. 2. Adjust Pick_AFlowTM switch. (Refer to explanation under FEATURES). (Page 6) -
Install grille
1. CI Insert the mounting springs into the slot as shown to mount grille to fan body.
INSTALLATION (NEW CONSTRUCTION)
IMPORTANT: Remove the tape placed on the damper and adaptor before
installation. Failure to do so will cause the product to work inefficiently
and create a loud noise.
WARNING
Disconnect power supply before installing the unit.
Please wear gloves to protect hands during the installation.
-
Remove adaptor from fan body
1. Disconnect plug connector from the receptacle and remove adaptor from fan body by removing the machine screw (M4X8) before installation. -
Install Flex-Z FastTM bracket
Flex-Z FastTM bracket position can be adjusted from 16″ to 24″ (406mm to 610mm) between joists.
1. Bend down 4 tabs and align bracket to the joist.
2. Align and install bracket to joist by using 2-preinstalled tapping screws.3. Extend bracket to the other joist.
4. Install bracket to joist by using 2-preinstalled tapping screws. -
Follow steps from “RETROFIT” Installation
1. Follow the steps 4 to 7 on ‘INSTALLATION (RETROFIT)”
MAINTENANCE (CLEANING)
WARNING
Disconnect power source before working on unit.
CAUTION
Routine maintenance must be done every year.
Please wear gloves during the cleaning work.
Never use gasolene, benzene, thinner or any other such chemicals for cleaning
the ventilating fan.
Do not Immerse motor in water when skirling. Do not soak resin pans In water
over 140°F (60°C).
Do not use cleaning sprays, solvents, or water on or near the sensor.
- Remove grille
- Maintenance of unit
1. Clean grille. (Don’t put into hot water. Use non-abrasive kitchen detergent, we dry with dean cloth.)
NOTE: The grille should be dry after cleaning. 2. Remove dust and dirt from fan body using a vacuum cleaner. 3. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with Clean cloth. Reinstall grille after finishing.
PRACTICAL GUIDE TO INSTALLATION
Properly insulate the area around the fan to minimize building heat loss and gain. Loose fill or bait insulation can be placed directly over the fan housing in the attic. Our fans do not create excessive heat that is a common problem with recessed light fixtures or some competitor’s fan/light combination. Our efficient cool-running motors do not create enough ambient heat to be subjected to these limitations. The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.
SPECIFICATIONS
HVI Certified performance based on HVI Procedures 915, 916, 920 at 01″ WG.
Model No.| Air direction| Voltage (v)| Frequency (Hz)| Duct diameter (inches)|
Air volume
(CFM)| Noise (sones)| Speed (rpm)| Power OM| Weight lb. (kg)
---|---|---|---|---|---|---|---|---|---
RG-C811LHA| Exhaust| 120| 60| 4 or 6| 80| <0.3| 824| 7.| 10.1(4.6)
110| 0.5| 984| 11.
PRODUCT SERVICE
Warning Concerning Removal of Covers. The unit should be serviced by qualified
technicians only. Your product is designed and manufactured to ensure a
minimum of maintenance. Should your unit require service or parts, call
Panasonic Call Center at 1-866-292-7299
(USA).
Panasonic Corporation of North America 2 Riverfront Plaza Newark, NJ 07102
Panasonic Ventilating Fan Limited Warranty
Panasonic Corporation of North America (“the Warrantor”) will, at its sole
discretion, replace this product with new parts or exchange this product, free
of charge, in the USA, in the event of defects in material or workmanship in
accordance to the following:
ALL Parts: For period of 3 years (36 months)
DC Motor. For period of 6 years (72 months)
LED Light Unit: For a period of 5 years (60 months)
Service in the USA, can be obtained during the warranty period by contacting
the selling Distributor or Panasonic Customer Call Center at
1-866-292-7299, toll free. This
warranty does not cover labor charges for removal and installation of parts.
This warranty is extended only to the original purchaser of a new product,
which was not sold “as is”, who purchased the product either directly from the
Warrantor or from the Warrantor’s authorized resellers (including authorized
retail and Internet-based sellers), unless otherwise prohibited by law. This
warranty only applies to products purchased in the United States.
To claim warranty proof of purchase date will be required, in addition to fan
model and serial number as shown in the photos below.
This warranty only covers failures due to defects in materials or workmanship
that occur during normal use and does not cover shipping damages, whether
visible or concealed, normal wear or cosmetic damage. The warranty does not
cover failures that are caused by products and peripherals not supplied by the
Warrantor, or failures which result from accident, misuse, abuse, negligence,
mishandling, misapplication, alteration, modification, faulty installation,
improper setups or adjustments, improper or lack of maintenance, alterations
or modifications, power line surge, improper line voltage, lightning damage,
or damage that is attributable to acts of God.
LIMITS AND EXCLUSIONS
There are no express warranties except as listed above. THE WARRANTOR SHALL
NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL, OR PUNITIVE DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOSS OF GOODWILL PROFITS OR REVENUE, LOSS OF USE OF THIS
PRODUCT OR ANY ASSOCIATED EQUIPMENT, COST OF SUBSTITUTE PRODUCT, DOWNTIME
COST, OR CLAIMS OF ANY PARTY DEALING WITH BUYER FOR SUCH DAMAGES, RESULTING
FROM THE USE OF THIS PRODUCT OR ARISING FROM BREACH OF WARRANTY OR CONTRACT,
NEGLIGENCE OR ANY OTHER LEGAL THEORY, EXCEPT AS EXPRESSLY PROVIDED ABOVE.
THERE IS NO WARRANTY OR ANY OTHER KIND, EXPRESS OR IMPLIED, THERE ARE NO
WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, or limitations on how long an implied warranty lasts,
so the above exclusions or limitation may not apply to you.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
If a problem with this product develops during or after the warranty period,
you may contact your Distributor or Panasonic Customer Call Center. If the
problem is not handled to your satisfaction, then write to Panasonic
Corporation of North America at the address indicated above.
Customer Support
Obtain Product Information and Operating Assistance by visiting our website
at: us.panasonic.com/ventfans
or, send your request by E-mail to:
ventfans@us.panasonic.corn
You may also contact us directly for technical and warranty support at
1-866-292-7299 Please follow the voice
prompt for consumers (Monday-Friday, 9 am – 6 pm, EST)
Accessory Purchases
Purchase Parts and Accessories for all Panasonic Ventilation Products by
visiting our website at:
www.buybanasonicparts.com
You may also contact us directly at
1-866-292-7299 Please follow the voice
prompt for consumers (Monday-Friday , 9 am – 6 pm, EST)
Panasonic Consumer Electronics Company Customer Service Group 2 Riverfront
Plaza, Newark, NJ 07102
Panasonic Corporation of North America . . Printed in Mexico
‘Two Riverfront Plaza, Newark, Nu 07102
© Panasonic Corporation 2022
Poa22-0 CB11LH420
www.panasonic.com
C811LH420
Documents / Resources
|
Panasonic C811LH420 Whisper Choice DC with LED light and Humidity
Sensor
[pdf] Instruction Manual
C811LH420 Whisper Choice DC with LED light and Humidity Sensor, C811LH420,
Whisper Choice DC with LED light and Humidity SensorLED light and Humidity
Sensor, Humidity Sensor
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>