Lightstar LMSA-2000 AIRLITE 1000W LED Light User Manual
- June 4, 2024
- Lightstar
Table of Contents
Lightstar LMSA-2000 AIRLITE 1000W LED Light
PRODUCT OVERVIEWS
Lightstar LED Airlite is a Bi-Color LED Airlite, Hi-efficiency and Energy-
saving,
low power consumption, low operating temperature, none ultraviolet radiation,
long service life, color temperature 2800-6500 continuously adjustable,
support cable DMX or Wireless DMX control, easy to use, meet different
shooting scenes.
PRODUCT FEATURE
- 360 ° even light
- High quality white light ,CRI95 ,brightness 0-100% adjustable
- The color temperature can be adjusted continuously between 2800K-6500k
- Support DMX51 2 communication protocol, LCD software control, multifunction, easy to operate
- Low power consumption, low operating temperature, green, energy-saving and environmental protection
- None-ultraviolet radiation , low operating temperature , long service life reduces the cost
- Inflate and replenish air automatically, easy to operate
- The total luminous flux is relatively stable when adjusting the color temperature
PERFORMANCE
- MODEL NO.: LMSA-2000
- Net Weight: 8Kg
- Rated input: 100-240V
- Weight of Ballast: 3.5kg
- Output power: 1 OOOW
- IP Class: IP20 Diameter
- Color temperature:2800K 6500K
- Dimensions: 4)300×1500L(mm)
- IP Class: IP20 Diameter:
ψ1800(mm)
Packing List
Operating Introduction.
-
Brief introduction
The product is an adjustable bio-color temperature LED light. The brightness adjustment range is 0-100%, temperature adjustment range is 2800-6500K, strobe frequency adjustment range is 0-50Hz, and duty cycle adjustment range is 1-99%. User could choose to control on panel, DMX, WDMX. The input power is 100-240VAC, and the frequency is 50HZ/60HZ. High voltage in it, pay attention to safety!!! -
Operating Panel Function
There are three parts on operating panel: Operating keys, LCD, and adjustment knob. There are three parts on operating panel: Operating keys, LCD, and adjustment knob. Operating buttons consists four keys, M, A., B and E. Click button M to enter menu and return to upper level menu. Click button A to select up, click button B to select down, click button E to enter. In addition, the operating buttons provide a quick link function under main screen, Click button B to ON/OFF light, Click button A to enter brightness adjustment and color temperature adjustment, Click button E to enter Silence mode, when the light is on, the cover is in inflated state, select Button E to turn on the fan mute, the fan will slow down immediately and enter the air supplement mode LCD display is used to display operating functions and parameters. The adjusting knob is used to adjust the parameters. -
Power on
-
Power On Power on the light, the fan will inflate at 100% speed automatically. After 10 second, the light brightness will turn on 10% brightness. 1 minute later, the light brightness becomes 100%. 2 minutes later, the light is full and inflation completed, the light enter Fan Mode, the fan turn to 20% speed, and the light run automatically
-
Fan Mode Enter Fan Mode from Menu, or click Button E to enter Silence Mode, to reduce fan noisy satisfy the special shooting environment, the fan speed become 15%. The Fan control function is not available under Fan Mode. If need inflation, pls turn off Silence Mode, then the Fan restore to 20% speed automatically. Also you can enter fan control menu to adjust fan speed.
-
Hot Restrike
Once the lamp restarted, the lamp will Power On. According to 3.1, it will inflate at full speed for 2 minutes. To prevent overload, if the airline is full, you can click Button E to stop inflation, the light will enter Silence Mode. After 2 minutes, you can turn off the Fan Mode, enter 20% speed inflation. -
Operating Instructions The home screen is brightness adjusting screen, using adjusting knob to adjust brightness. Select Button A switch to color temperature adjustment screen, using adjusting knob to adjust color temperature. Select Button A or M switch to home screen. As follow figure.
Select Button M or quick link button E to enter Light mode selection screen. At Light Mode selection screen, select quick link button A/B enter light mode, select Button E to enter light parameter adjustment screen. On the Light Mode screen, select the corresponding adjustment parameters by select operating buttons, and then adjust the parameter data by adjusting the knob. select button B to enter other lighting data screens. Enter Fan Mode, select Speed, adjust the fan speed through FAN Mode the knob to ensure that the internal pressure of the cover Speed 20% is sufficient; select Silence to turn on the fan mute, the fan will Siledce off slow down immediately and enter the air supplement mode.
-
DMX Control Fan Mode There are two kinds of DMX signal control, wireless DMX and DMX signal control Default is DMX signal. On ballast front panel, there is a five-core XLR input & output interface. There is a wireless DMX antenna on the side of ballast. The foot of five-core XLR input & output interface is defined as follow:
-
Data Link Common Port
-
Signal
-
Signal +
-
5 No N/A
On menu screen, select DMX Setup to enter DMX Add setting screen, set DMX
starting and ending address (1-512) by adjusting the knob. Select Button A/B
to select DMX (wired) switch and WDMX switch. Select Button E to select ON/OFF
to set “DMX” state. WDMX is used for setting LumenRadio wireless module built-
in. Select Button E to set ON/OFF state. If need reset, select Button B then
select WDMX Reset, select Button E, the wireless module is reset successfully.
2.4G Wireless Module DMX Instruction
Corresponding relationship between ID code and LED color:
-
RED— –RED
-
GREEN- -GREEN
-
RED+GREED -YELLOWN
-
BLUE- —BLUE
-
RED+BLUE -PURPLE
-
GREEN+BLUE- –BLUISH GREEN
-
RED +GREED +BLUE-WHITE
-
Click the push button, show current ID setting, click the push button the ID number increases 1
-
Working status LED is always on: No DMX or no signal Red LED flashing: Sending Green LED flashing: Receiving
-
RF frequency, 126 bands, selected automatically and does not need to set.
-
1D code– “1-7” group ID code, press “KEY” to adjust. only could communicate to the transceivers in same ID code.
Communication Establish
- Power on the sender and transceiver.
- Press “key”, set same ID for transceiver and sender. If there is more than one group of wireless LAN, make sure the ID of each network is NOT same.
- After sender receives the DMX data, the sender will select a non-interference frequency band, sending the data, RED LED flashing. The transceiver will change the communicate band, until get the same correct ID data, GREEN LED flashing, DMX data communications the more fast, the LED flasing more fast.
- The communication is established.
Notice and Maintenance
- OLED’ S operating temperature range must be guaranteed between -20°C+40 C.Overheat or under cooling can both reduce its service life.
- The product must be placed on a solid, flat and dry surface. The surface temperature should be less than 50 C. Avoid exposure to direct sunlight and operating in an environment with high humidity or explosive gas.
- Do not beat, knock or shake the light violently, or it may influence the normal use or the light.
- Do not cover lamps with paper, cloth or similar materials during use.
- Put the lamp in a cool and dry place when you do not use it for a long time.
- Avoid any flammable liquid, water or metal material entering the machine. Cut off the power supply as soon as it happens.
- Do not use machines in dirty and dusty environments and clean them regularly
- The technicians must get professional trainings to install, operate or repair LED If the equipment cannot work normally, please contact with Lightstar s aftersales department or professional technicians. Do not disassemble/re-assemble the equipment by yourself.
- The cover is not available to wash by machine or water scrubbing. If necessary, pls clean it by a lint free soft cloth with clean water. Do not use chemical reagents.
Service Warranty Ordinance
Customers can enjoy one-year free warranty service as of the date of purchasing Our product.
- At the expiry of warranty period, users can still enjoy our repair service but the relevant cost will be charged. I
- n any of the following circumstances, the product is not repaired free of charge whether the warranty period expires or not. Damage caused by misuse or abuse, disassembly and non-original parts replacement Damage caused by natural disasters, unconventional voltage and environmental factors.
- 2017 Beijing Lightstar Electronic Corp. will remain the ultimate power of interpretation.
- Software version modification without further notice.
Web: www.lightstar.net.cn
E-mail: sales@lightstar.net.cn
Factory
Add:Tianshanguoji Industrial ParkYanjiao Development
Zone, Hebei Province, China
TEL: +86 10 51293309
Stock code: HE 4F (870818)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>