Lightstar LIGHTMAN 575 Electronic Ballast User Manual
- June 4, 2024
- Lightstar
Table of Contents
LIGHTMAN 575 Electronic Ballast
**User Manual
**
LIGHTMAN
575/1200/1800 EB
User Manual
Important Safety Instructions
- Disconnect EB from mains power before the power supply is prepared. Do not pull the connection cable with force.
- Before connecting the EB to mains power, ensure that the socket is correctly wired.
- The lamp head must be disconnected from power before changing or fitting the lamp.
- EB must be switched off before connecting or disconnecting the lamp head with the lamp head cable. To avoid any danger to the user and EB, we highly recommend using our original LIGHTMAN cables and connectors.
- The working temperature of the EB is guaranteed between – 20°C and 50°C · Do not operate the EB in high humidity or explosive gas environments
- within 3 minutes after startup, the ballast is locked and all operations are invalid (default frequency is 75Hz, brightness is 100%)
Product Overview
The 575/1200/1800 electronic ballast from our LIGHTMAN series provides an automatically switchable ballast for 575W / 1200W / 1800W metal halide lamps. It features high efficiency, power density, and automatic problem analysis.
- Flicker-free operation up to 10`000 fps (frames per second)
- fluctuation of output light is less than 3%
- compared to inductive EB, light intensity is increased by at least 20%
- constant power output
- constant color temperature
- 50% – 100% power output adjustment
- at least a 20% increase in service life (lamp)
- Output frequency: 50 – 1000Hz, Fine-Tuning range: 800Hz – 1200Hz
Technical Information
SKU:
Description:
Power:
Nominal Current:
Cooling:
Dimming:
Output Frequency:
AC Input:
Control:
Starting:
Frequency:
IP Class:
Dimensions:
Weight:| – EB
575W / 1200W / 1800W Electronic Ballast for Metal Halide Lamps 2600VA
11.5 – 16A P
Passive Cooling
50-100%
50/60/75/300/1000Hz
180-250V AC / 50/60Hz / 1 Phase
DMX In- & Output (5-Pin XLR socket)
LCD Display Cold start / hot restrike
1-50Hz
IP22
196 x 200 x 304mm
7`500g
---|---
Operational Instructions
Energizing System
- Check if the EB is disconnected from mains supply before connecting cables to the lamp head.
- Check if the main circuit breaker switch of the EB is in the off position
- Confirm if the lamp head meets the requirements of the EB
- Check the lamp head cable for visible damages
- If you followed all of these quick checks, you can connect the EB to the main supply and connect the lamp head.
- You are now ready to start the EB and change the settings.
Adjusting the System
- After preparing everything, you can now change your settings on the display of the EB.
- The LCD display turns on when the main circuit breaker is in the ON position.
- It should light up the L3 indicator (green)
- If the ground connection is correct, the L4 indicator is on. If this is not the case, check the power supply and socket.
- Turn on the ignition switch to ON – the light will ignite within 3 seconds. At the same time, the L1 indicator turns on (yellow)
- Wait for 3 minutes until the lamp is fully heated and the color temperature and brightness have a stable output. Then you can adjust the brightness value and frequency as needed.
LCD Display Control
After the EB hast power and the switch is on, this LCD display pops up. After
3 minutes the EB is locked and all operations cannot be dialled.75Hz below the
percentage shows the frequency setting. To change this value, just push
buttons A or B and change the frequency by turning the knob. The 25EB shows
which lamp is in use. It automatically identifies the lamp. If anything
doesn`t work properly, the ballast shows an error message. Press button E to
have a look at the EB data.
Fine Tuning for 1000Hz
Press button A to go to the 1000Hz fine-tuning screen. Adjust by rotating the
dimmer knob between 800Hz and 1200Hz. By pressing button B you return to the
main menu.
Error Codes
Press button M to enter the menu setting screen, then press button B to select
Parameters. Press push button E to enter the Parameter screen (Figure 4).
Select Fault Info and press button E again. Press button A or B to scroll
up/down to check the error codes. To return to the home screen – press button
M.
Error Codes
LE | System Error |
---|---|
TEMP | EB is overheating |
BUCK | Voltage Control has troubles |
L.V | The input Voltage is too low |
LAMP | Problems with lamp head/lamp defect |
Working Parameters Reference
Supply Voltage | 170 – 250V |
---|---|
Output Voltage | 575W – 90 – 110V |
1200W – 95-105V
1800W – 135 – 145V
Output Current| 575W – 6 -7A
1200W / 1800W – 12 – 14A
Input Current| 3-11A
PFC Voltage| 350 – 370°C
Working temperature| 40 – 80°C
DMX Control
Initial Address Set-Up
In the menu settings screen (Figure 3) press button B and select DMX Setup.
Then press E again to open the DMX address screen. Adjust the start address
with the dimming knob by turning it.
DMX Status
In the DMX Setup display press button B to select DMX Switch. Press E and
adjust the value with the dimming knob. Press M to get back to the menu
screen.
DMX Channels
The start address is CH1 – below 100 = OFF, above 100 = ON (lamp) Start
address +1 is CH2 – it is used for brightness adjustment ranging from 50% to
100%. Start address +2 is used for controlling the frequency:
DMX Value (8-bit) | Output Frequency (Hz) |
---|---|
0 – 50 | 50 |
51 – 100 | 60 |
101 – 150 | 75 |
151 – 200 | 300 |
201 – 255 | 1000 |
Start address +3 is used for 1000Hz fine-tuning. DMX Value 0 – 255
Notice and Maintenance
- LED`s operating temperature range must be guaranteed between – 20°C to +40°C. Overheating or undercooling can both reduce the fixture’s life span.
- The product must be placed on a solid, flat, and dry surface. The surface temperature should be less than 50°C. Avoid exposure to direct sunlight and operation in an environment with high humidity or explosive gas.
- Do not beat, knock or shake the light violently or it may influence the normal use of the light.
- Do not cover lamps with a paper, cloth or similar materials that could ignite due to high temperature.
- Put the lamp in a cool and dry place when you do not use it for a long time.
- Avoid any flammable liquid, water, or metal material entering the machine. Cut off the power supply as soon as this happens.
- Do not use machines in dirty and dusty environments and clean them regularly.
- The technicians must get professional training to install, operate or repair leds.
- If any equipment from Lightstar doesn`t work properly, please get in contact with a Lightstar special repair department or a professional technician. Do not disassemble or reassemble the parts by yourself.
Service Warranty Ordinance
Customers enjoy a one-year free warranty service as of the date of purchasing our product.
-
If the expiry date of the warranty is reached, our product can still be repaired for according to price.
-
In any of the following circumstances, the product is not repaired free of charge, whether the warranty period expires or not.
– Damage caused by misuse or abuse, disassembly, and non-original parts replacement.
– Damage caused by natural disasters, unconventional voltage, and environmental factors -
Lightstar will remain in the power of interpretation.
-
Software version modification without further notice.
When anything doesn`t work correctly the user can confirm the error code and check the further procedure with our customer support team. We always try to offer quick solutions, whenever possible. Do not open any device without the explicit consultation of Lightstar. The repair must be carried out with our guidance or if not possible by our technician team.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>