RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA Instructions

June 4, 2024
RAB

RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA
Instructions

RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA

INSTRUCTIONS
6″ Residential Retrofit Adjustable FA
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
RA6R109FAl20WS RA6R119FAl20WS

IMPORTANT

READ CAREFULLY BEFORE INSTALLING THE FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNINGS:

  • Risk of electrical shock. Disconnect power at fuse or circuit breaker before installing or servicing.
  • To prevent early lamp failure, lamps should only be installed in operating environments ranging between-30 C and +40-0 (-22°F and+104°F).
  • No user-serviceable parts inside. To avoid electrical shock do not disassemble the product.
  • Risk of fire or electric shock, LED Retrofit Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • Risk of fire or electric shock, Install this kit only in luminaires that have the construction features and min dimensions shown in Figure 1 and where the input rating of the retrofit kit does not exceed the input rating of the luminaire
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation
  • To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
  • Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals, Instead, installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lampholder lead wires by employing applicable connectors.
  • This retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by authorities having jurisdiction.
  • This device is not intended for use with emergency exits.
  • These retrofit kits are suitable for wet locations luminaires specified as below: Type Non IC; Type IC; Covered ceiling Uncovered ceiling. Installers should examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit.

NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance

WHAT’S IN THE BOX

RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA -
BOX

TOOLS NEEDED

The Recessed LED Downlight is designed to fit into a 6″ housing. No tools are necessary for installation.
MIN.LUMINAIRE DIMENSION
RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA - fig
7

OPTIONAL ACCESSORIES

RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA - fig
6

6″ Band with Friction clips
RFLED-RETRO BAND For use with 6′ housings without torsion spring receivers with an internal diameter of 165.1-171.45mm

INSTALLATION INSTRUCTIONS

1. Make sure the power is turned off at the source to the recessed housing(s) that you are installing the fixture(s) in. Remove existing trim and CFL, or Incandescent bulbs.
2a. Unscrew the screws on socked bracket, push the bracket upward to the top location. (Fig. 2a)RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable
FA - fig 5

2b. Remove the existing socket mounting plate from the recessed housing and then remove lamp socket from the plate. (Fig. 2b)
RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA - fig
43. Screw the E26 base adapter into a socket in the recessed housing.(Fig. 3)

RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA - fig
3

4. Select desired CCT.(Fig. 4)RAB RA6R109FA120WS 6 Inch Residential
Retrofit Adjustable FA - fig 2

5. Plug the E26 base cable connector into the LED Recessed Kit. Make sure the kit is grounded. (Fig. 5)RAB RA6R109FA120WS 6 Inch Residential Retrofit
Adjustable FA - fig

6. Squeeze torsion springs together as shown and install into torsion spring brackets inside recessed housing. For proper installation, the torsion springs should be seated within the brackets and on both sides of the housing. (Fig. 6)RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA - DRAWINGS
2

7. Carefully route wires into fixture and push Recessed Kit up flush to ceiling surface. Push the edge of the bezel to tilt lens up to 30°. Rotate lens assembly horizontally towards the surface to be illuminated. (Fig. 7)

RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA - DRAWINGS
1

DIMENSIONAL DRAWINGS

RA6R109FA120WS
RA6R119FA120WS

RAB RA6R109FA120WS 6 Inch Residential Retrofit Adjustable FA -
DRAWINGS

Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly – sales@rablighting.com
Free Lighting Layouts
Answered online or by request
2022 RAB LIGHTING Inc.
Cranbury, New Jersey 08512 USA
RAXX9FA-IN-0721

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals