EYEDRO-HOME Electricity Monitoring System User Guide
- June 12, 2024
- Eyedro
Table of Contents
Quick Start Guide
Home Electricity Monitoring System (Single Phase)
with Ethernet/Wi-Fi (2.4GHz) connectivity
Model: EYEDRO-HOME
For applications not exceeding
200A / 300VAC
Verify Package Contents
| Quantity| Description
---|---|---
A| 1| Eyedro module (2 port)
B| 2| 200A current sensor
C| 1| 6VAC power adapter
D| 1| 3m (10ft) Ethernet cable
Record Serial Number:
(located under barcode on module)
Install Hardware
3.1 Install current sensors on the line¹ conductor of the circuit(s) to
be monitored.
¹Line/Live/Hot conductor(s) 3.2 Connect sensors, Ethernet cable (if using)
and power adapter to the Eyedro module.
Connect Device to the Internet
4.1 If connecting by Ethernet, connect one end of the supplied Ethernet
cable to an open port on your router and the other end to the Eyedro module.
Ethernet cable must be connected before powering device
4.2 If connecting by Wi-Fi (2.4GHz), use your computer or mobile device
to connect to the Wi-Fi network created by your Eyedro: Eyedro [Serial#].
4.2.1 Open a browser tab and go to
4.2.2 From the Wi-Fi Settings page, enter the name (Network SSID) and
password (Key) for the Wi-Fi network in your building. Click Connect.
4.2.3 Reconnect your mobile device or computer to the network that you
just passed to your Eyedro.
Create a MyEyedro User Account
5.1 Go to my.eyedro.com to create your online
account (or log in if you have an existing account). 5.2 Add the device to
your user account: go to Configuration, select Devices then enter the serial
number you recorded in Step 2.
5.3 ENJOY! Log into MyEyedro as often as you like to view your
electricity consumption.
5.4 For more details about the MyEyedro cloud service, review the
MyEyedro User Guide located at eyedro.com/support
Before Getting Started
This Quick Start Guide provides very high level installation instructions.
Detailed installation instructions are available in the Product Guide at
eyedro.com/support
This product is intended for indoor use only
Installation may require the cover of the main electrical panel to be removed
while some wires are still electrified. Even when the main breaker has been
turned ‘OFF’ certain areas of the panel may still be dangerous and carry the
risk of shock, burn, and electrocution.
Installation should be performed by a qualified electrician.
DO NOT attempt installation unless you know where electrified areas within the
panel are.
Notes:
- Always use the AC power adapter that came with your EYEDRO-HOME system.
- Do not plug your Eyedro power adapter into an Uninterruptible Power Supply (UPS) as this will result in incorrect measurements.
Online Support Resources
Visit eyedro.com/support for online product setup
wizard, user manuals, videos, and various support resources
Limited One Year Warranty
Full warranty details are available in the Product Guide at
eyedro.com/support.
Important: This product contains no user serviceable components. Do not
attempt to open the case of the unit or tamper with the internal components.
Doing so will void the product warranty.