Eyedro E5B-M-GWE3 Wireless Mesh Energy Monitoring System User Manual

June 11, 2024
Eyedro

Eyedro LOGO

Eyedro E5B-M-GWE3 Wireless Mesh Energy Monitoring System

Eyedro-E5B-M-GWE3-Wireless-Mesh-Energy-Monitoring-
System

Wireless Mesh Energy Monitoring System

The Wireless Mesh Energy Monitoring System includes a gateway and is designed for 3-Phase only. The model number is E5B-M-GWE3.

Before Getting Started

Complete installation instructions can be found at eyedro.com/support. Installation may require the cover of the main electrical panel to be removed while some wires are still electrified. Even when the main breaker has been turned OFF certain areas of the panel may still be dangerous and carry the risk of shock, burn, and electrocution. Installation should be performed by a qualified electrician. DO NOT attempt installation unless you know where electrified areas within the panel are.

Notes:

  1. Always use the power adapters that came with your E5B-M-GWE3 system.

  2. Do not plug your Eyedro power adapter into an Uninterruptible
    Power Supply (UPS) as this will result in incorrect measurements.

  3. The AC power adapter must be powered via a circuit that is downstream of the panel where the current sensors are installed.

Limited One Year Warranty

Eyedro Green Solutions Inc. warrants this product for a period of one year from date of purchase for all defects in material and workmanship. Defective parts may be repaired or replaced at the discretion of the manufacturer during this period. Full warranty policy details are available at eyedro.com.

Product Before Getting Started

This insert provides very high level installa-tion instructions. Complete installation in-structions can be found at eyedro.com/support (see Product Manual and Support videos)

Installation may require the cover of the main electrical panel to be removed while some wires are still electrified. Even when the main breaker has been turned ‘OFF’ certain areas of the panel may still be dangerous and carry the risk of shock, burn, and electrocution. Installation should be performed by a quali-fied electrician. DO NOT attempt installation unless you know where electrified areas within the panel are.

Notes:

  1. Always use the power adapters that came with your E5B-M-GWE3 system.
  2. Do not plug your Eyedro power adapter into an Uninterruptible Power Supply (UPS) as this will result in incorrect measurements.
  3. The AC power adapter must be powered via a circuit that is downstream of the panel where the current sensors are installed.

Quick Start Guide

Verify Package Contents

Qty. Description
A Eyedro gateway module
B Eyedro sensor module (3 port)
C 1 5VDC power adapter (gateway)
D 1 6VAC power adapter (sensor)
E 3 current sensors
F 1 Ethernet cable (3 ft.)

Record Serial Numbers:

The serial numbers can be found under the barcode on each module. Record the Gateway SN and Sensor SN for later use.

Install Hardware

  1. Install current sensors on the line1 conductor of the circuit(s) to be monitored.
  2. Connect one end of the supplied Ethernet cable to an open port on your router.
  3. Connect current sensors and power adapter to the sensor module.
  4. Connect Ethernet cable and power adapter to the gateway module.
    Always use the correct power adapter! Use the 5VDC power adapter with the gateway module and the 6VAC power adapter with the sensor module.

Create a MyEyedro User Account

  1. Go to my.eyedro.com to create your online account (or log in if you have an existing account).
  2. Add the devices to your user account: go to Configuration, select Devices then enter the serial numbers you recorded in Step 2.
  3. Log into MyEyedro as often as you like to view your electricity consumption.
  4. For more details about the MyEyedro cloud service, review the MyEyedro User Guide located at eyedro.com/support.

For any questions or comments, visit eyedro.com. We value your feedback. Support manuals and videos are also available at eyedro.com/support.

Verify Package Contents

Eyedro-E5B-M-GWE3-Wireless-Mesh-Energy-Monitoring-
System-1

  Qty. Description
A 1 Eyedro gateway module
B 1 Eyedro sensor module (3 port)
C 1 5VDC power adapter (gateway)
D 1 6VAC power adapter (sensor)
E 3 200A current sensor (no sensors in-

cluded with –SUB systems)

F| 1| Ethernet cable (3 ft.)

Record Serial Numbers

(located under barcode on module)

Eyedro-E5B-M-GWE3-Wireless-Mesh-Energy-Monitoring-
System-2

Install Hardware

  1. Install current sensors on the line1 conductor of the circuits(s) to be monitored.
    1Line/Live/Hot conductor(s)

  2. Connect one end of the supplied Ethernet cable to an open port on your router.

  3. Connect current sensors and power adapter to the sensor module.

  4. Connect Ethernet cable and power adapter to the gateway module.

Create a MyEyedro User Account

  1. Go to my.eyedro.com to create your online account (or log in if you have an existing account).
  2. Add the devices to your user account: go to Configuration, select Devices then enter the serial numbers you recorded in Step 2.
  3. ENJOY! Log into MyEyedro as often as you like to view your electricity consumption.
  4. For more details about the MyEyedro cloud service, review the MyEyedro User Guide located at eyedro.com/support

Always use the correct power adapter!

Use the 6VAC power adapter with the sensor module:

Product Limited One Year Warranty

Eyedro Green Solutions Inc. warrants this product for a period of one year from date of purchase for all defects in material and work-manship. Defective parts may be repaired or replaced at the discretion of the manufacturer during this period.
Full warranty policy details are available at eyedro.com

Copyright © 2022, Eyedro Green Solutions Inc.

Support manuals and videos:
Eyedro.com/support

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>