1. Unpack box and make sure you have all items shown here.
(Screwdriver not shown.)

SECURITY BRANDS Edge E1 Smart Keypad - Unpack box

2. Unlock and open front panel of unit for mounting, wiring, and setup.

SECURITY BRANDS Edge E1 Smart Keypad - front panel

3. Mount unit to pedestal using included mounting hardware.
(This step may be completed later.)

SECURITY BRANDS Edge E1 Smart Keypad - hardware

WARNING
AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING!
REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED!
CAUTION
Use all four carriage bolts when mounting the unit to a pedestal.
Leave the antenna in place.
Seal all openings created in the enclosure.
Failure to follow these instructions can damage the unit and/or cause it not to function correctly!

What’s what?

All important components labeled

SECURITY BRANDS Edge E1 Smart Keypad - components

Unit shown with front panel open.
Wiring/cabling not shown for clarity.

SECURITY BRANDS Edge E1 Smart Keypad - Mounting

Card Reader Mounting Location
For mounting Wiegand proximity card reader (sold separately).
See Edge E3 Quick Start Guide or Edge Direct Programming Manual for programming instructions.

4. Connect wires.
Feed wires through back of unit, and connect as shown using included screwdriver.
Excessive force can damage unit!
Additional wiring diagrams can be found on Pages 5 and 6.
CAUTION
If the included 12-V AC/DC adapter will not be used, please go to Page 4 and follow the procedure, Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage the unit!

SECURITY BRANDS Edge E1 Smart Keypad - wire

Using a Third-Party
Power Source (Optional)
IMPORTANT
If you would like to use a third-party power source such as solar, verify that it conforms to the following specs:

Input| 9–30 VAC/DC
no more than 10% beyond this range
---|---
Current Draw| less than 111 mA @ 12 VDC
less than 60 mA @ 24 VDC

4a. Connect wires to unit as shown in Step 4.
4b. Connect wires to your power source, making sure you connect positive to positive and negative to negative.
CAUTION
Double check that you have wired from positive on the Edge unit to positive on your power source and negative on the Edge unit to negative on your power source.
Reverse polarity can damage the unit!
5. Close front panel of unit and lock it.

SECURITY BRANDS Edge E1 Smart Keypad - panel

STOP
Before going forward, double check all wiring and make sure the unit has power!
Wiring diagrams for connecting to accessory devices can be found on Pages 5 and 6.
For connecting accessories not mentioned, please contact Technical Support.
Make sure the gate or door path is clear before completing Step 7!
6. Add Access Code to Relay A.
(To add multiple codes, enter each of them before pressing pound key.)

SECURITY BRANDS Edge E1 Smart Keypad - Relay A

NOTE: The green arrow indicates a “good” tone on the Edge unit. By default, the following codes are reserved and cannot be used: 1251, 1273, 1366, 1381, 1387, 1678, 1752, and 1985.
7. Make sure gate or door path is clear; then enter access code on keypad, and confirm gate or door opens.

SECURITY BRANDS Edge E1 Smart Keypad - confirm gate

SECURITY BRANDS Edge E1 Smart Keypad - ICON 3INSTALLATION COMPLETE!
Jump to Page 7 to continue programming and download the Edge Smart Keypad app.

A. Event Inputs
Wiring for accessories such as a request-to-exit device
Edge Power, Relay, and Event Terminals

SECURITY BRANDS Edge E1 Smart Keypad - Event Inputs

Event Input configuration instructions can be found on Pages 10 and 11.
B. Digital Inputs
Wiring to various accessories
Edge Digital Input Terminals

SECURITY BRANDS Edge E1 Smart Keypad - Digital Inputs

Digital Inputs can be configured using the Edge Smart Keypad app.
C. Wiegand Device
Wiring for a Wiegand device
Wiegand configuration instructions can be found on Page 14.

SECURITY BRANDS Edge E1 Smart Keypad - Wiegand Device

If mounting a Wiegand card reader to the Edge unit front panel, remove the existing cover plate and hex nuts to reveal the mounting holes and wiring passthrough hole.
CAUTION
Disconnect power to the Edge unit before connecting Wiegand devices.
Failure to disconnect power can damage the unit!

Downloading the Edge Smart Keypad App for iOS/Android

The Edge Smart Keypad app is for ADMINISTRATOR USE ONLY and is not intended for users.
a. Grab your smartphone or tablet. (These steps are optional. Unit can be fully programmed from keypad.)
b. Navigate to your app store, and search for “edge smart keypad.”
c. Find the Edge Smart Keypad app by Security Brands, Inc. and download it.
Edge Smart Keypad
Security Brands, Inc.
NEED HELP
You can find plenty of useful resources online to help you get your new Edge unit up and running quickly and easily.
Go to securitybrandsinc.com/edge/
If you need further assistance, please call Technical Support at 972-474-6390.

D. Pairing Edge Unit
Connecting your mobile device to your Edge unit for use with app.
The app is available for administrators who want to use it. Nearly all functionality is available through direct programming via the keypad.
IMPORTANT! Make sure your Edge unit is powered on and that Bluetooth is enabled on your mobile device or pairing will not work.
Step 1 – Grab your mobile device and open the Edge Smart Keypad app.
If you do not have the app, follow the steps on this page for downloading it.
Step 2 – Fill out your account information and tap the “Sign Up” button.
If you have already created an account, you will log in instead.
Step 3 – On the Paired Keypads screen, tap the “Add Keypad” button.
Step 4 – On the Add Keypad screen, tap the Edge unit you want to pair.
If you do not see any Edge units listed, make sure your Edge unit is powered on and is in Bluetooth range.
Step 5 – Complete the procedure shown on your mobile device.
These steps will be completed using the PIN pad on your Edge unit.
Step 6 – Enter the Master Code (default is 1251) on your mobile device.
Step 7 – Enter the code shown on your mobile device at the Edge unit.
This step must be completed within the time duration displayed.
Step 8 – Change your Master Code if you like.
This step is recommended, but optional, and can be done at a later time.
Your new Edge unit is now be paired and will appear on the Paired Keypads screen. Tapping on the Edge unit on this screen will give you access to relay control and full access control management of the Edge unit from within the app.
** For more information and guidance, please go to securitybrandsinc.com/edge/** or call Technical Support at 972-474-6390 for assistance.

E1. Direct Programming / Unit Configuration
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.
By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985.
FIND MORE
For all programming not shown here, as well as reset procedures and the Edge Smart Keypad app user guide, please visit our Edge start page: securitybrandsinc.com/edge/
Change Master Code
(Highly recommended for security purposes)

SECURITY BRANDS Edge E1 Smart Keypad - Programming 1

Change Sleep Code

SECURITY BRANDS Edge E1 Smart Keypad - Programming 2

Programming Sub Modes

1 Add Access Code(s) to Relay A
2 Delete Code (Non-Wiegand)
3 Change Master Code
4 – 3 Add Latch Code to Relay B
4 – 4 Change Sleep Code
4 – 5 Change Code Length (Non-Wiegand)
4 – 6 Change Relay Trigger Time
4 – 7 Enable/Disable Timers and Schedules
4 – 8 Enable/Disable “3 Strikes, You’re Out”
4 – 9 Configure Event Input 1
5 Add Latch Code to Relay A
6 Configure Wiegand Inputs
7 Add Access Code(s) to Relay B
8 Add Limited-Use Code
0 Delete All Codes and Timers

*Things to Know
The Star Key (
)
If a mistake is made, pressing the star key deletes your entry. Two beeps will sound.
The Pound Key (#)**
The pound key is good for one thing and one thing only: exiting programming mode.

E2. Direct Programming / Unit Configuration
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.
Change Code Length
IMPORTANT! THIS WILL DELETE ALL NON-WIEGAND ACCESS AND LATCH CODES!

SECURITY BRANDS Edge E1 Smart Keypad - Programming 3

Change Relay Trigger Time

SECURITY BRANDS Edge E1 Smart Keypad - Programming 4

Enable/Disable Timers and Schedules

Enable/Disable “3 Strikes, You’re Out”
(When enabled, the unit will sound an alarm and go into a 90-second lockdown for 90 seconds when an incorrect code is entered three times.

SECURITY BRANDS Edge E1 Smart Keypad - Programming 6

E3. Direct Programming / Unit Configuration
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.

Toggle Silent Mode
(Toggles Silent Mode, which mutes all audible-tone feedback on unit)

SECURITY BRANDS Edge E1 Smart Keypad - Programming 7

Configure Event Input 1
(Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.)
Mode 1 – Remote Open Mode
Triggers either Relay A or Relay B when event input state changes from normally open (N/O) to normally closed (N/C).
Mode 2 – Log Mode
Makes log entry of event input state when event input state changes from normally open (N/O) to normally closed (N/C).
Mode 3 – Remote Open and Log Mode Combines Modes 1 and 2.
Mode 4 – Arming Circuit Mode
Enables either Relay A or Relay B when event input state changes from normally open (N/O) to normally closed (N/C). Otherwise, selected relay is disabled.
Mode 5 – Remote Operation Mode
Triggers or latches either Relay A or Relay B when event input state changes from normally closed (N/C) to normally open (N/O).
Mode 0 – Event Input 1 Disabled
Modes 1, 3, and 4

SECURITY BRANDS Edge E1 Smart Keypad - Programming 8

E4. Direct Programming / Unit Configuration
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.
Configure Event Input 1 (continued)
(Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.)

Mode 2

SECURITY BRANDS Edge E1 Smart Keypad - Programming 9

Mode 5

SECURITY BRANDS Edge E1 Smart Keypad - Programming 10

Disable Event/Digital Inputs (Mode 0)

SECURITY BRANDS Edge E1 Smart Keypad - Programming 11

E5. Direct Programming / Unit Configuration
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.
Configure Wiegand Input
(Allows enabling or disabling of a Wiegand input and configuration of the Wiegand device type. For the tag reader type, use the Edge Smart Keypad app.)

SECURITY BRANDS Edge E1 Smart Keypad - Programming 12

Change Default Facility Code

SECURITY BRANDS Edge E1 Smart Keypad - Programming 13

F1. Direct Programming / Onboard Keypad
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.
By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985.
Add Access Code(s) to Relay B
(To add multiple codes, enter each of them before pressing pound key)

SECURITY BRANDS Edge E1 Smart Keypad - Programming 14

F2. Direct Programming / Onboard Keypad
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.
By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985.

Add Latch Code to Relay A

SECURITY BRANDS Edge E1 Smart Keypad - Programming 15

Add Latch Code to Relay B

SECURITY BRANDS Edge E1 Smart Keypad - Programming 16

Delete Code (Non-Wiegand)

SECURITY BRANDS Edge E1 Smart Keypad - Programming 17

Add Limited-Use Code
(Access codes can be given a use or time restriction. For more advanced time restrictions, use the Edge Smart Keypad app.)

SECURITY BRANDS Edge E1 Smart Keypad - Programming 18

G1. Direct Programming / External Wiegand Keypad
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.

Add Wiegand Keypad Access Code(s)
(Uses default facility code; to add multiple codes, enter each of them before pressing pound key)
On Both Wiegand Inputs

SECURITY BRANDS Edge E1 Smart Keypad - Programming 19

On Wiegand Input 1 or 2

SECURITY BRANDS Edge E1 Smart Keypad - Programming 20

Add Wiegand Keypad Manager Access Code(s)
(Uses default facility code; to add multiple codes, enter each of them before pressing pound key)
On Both Wiegand Inputs

SECURITY BRANDS Edge E1 Smart Keypad - Programming 21

On Wiegand Input 1 or 2

SECURITY BRANDS Edge E1 Smart Keypad - Programming 22

G2. Direct Programming / External Wiegand Keypad
Green arrow indicates “good” tone on unit.
Always wait for good tone before moving on.

Add Wiegand Keypad Latch Code(s)
(Uses default facility code; to add multiple codes, enter each of them before pressing pound key)
On Both Wiegand Inputs

SECURITY BRANDS Edge E1 Smart Keypad - Programming 23

On Wiegand Input 1 or 2

SECURITY BRANDS Edge E1 Smart Keypad - Programming 24

Delete Wiegand Keypad Code(s)
(Uses default facility code; to delete multiple codes, enter each of them before pressing pound key)
On Both Wiegand Inputs

SECURITY BRANDS Edge E1 Smart Keypad - Programming 25

On Wiegand Input 1 or 2

SECURITY BRANDS Edge E1 Smart Keypad - Programming 26

H. Reset Procedures
NOTE:
If an error is made during these procedures, an “error” tone will sound, and you must start again from the beginning.

Master Code Reset

This procedure will reset the Master Code to the default value. No other stored data will be affected.
Step 1 – Open front panel on unit.
Step 2 – Locate, press, and hold Factory Reset (FAC. RST.) Button.
Hold down for about 10 seconds until three (3) beeps sound.
Step 3 – While still holding Factory Reset (FAC. RST.) Button, press star key (*) on keypad three (3) times.
Unit will sound good tone if successful.
Step 4 – Release Factory Reset (FAC. RST.) Button.
The Master Code is now reset to the default value (1251).

Unit Reset

This procedure will reset the unit back to factory settings. It will erase all codes and timers in memory and reset the Master Code back to the default value.
IMPORTANT! THIS PROCEDURE WILL RESET THE UNIT TO FACTORY SETTINGS AND ERASE ALL STORED INFORMATION, INCLUDING CODES AND TIMERS!
Step 1 – Open front panel on unit.
Step 2 – Locate, press, and hold Factory Reset (FAC. RST.) Button.
Hold down for about 10 seconds until three (3) beeps sound.
Step 3 – While still holding Factory Reset (FAC. RST.) Button, press pound-star-pound (#*#) on keypad.
Unit will sound good tone if successful. Release Factory Reset Button.
Step 4 – Enter Master Code (default 1251) on keypad.
After about 15 seconds, unit will start sounding a continuous cycle of tones to indicate all data has been deleted.
Step 5 – Power off unit and immediately power back on.
The unit is now reset to factory settings.

SECURITY BRANDS LOGO 2 NEED HELP
Call972-474-6390
Emailtechsupport@securitybrandsinc.com
We are available Mon–Fri / 8am–5pm Central
© 2023 Security Brands, Inc.
All rights reserved.

QSG-2721027215-EN
Rev. D (3/2023)

Documents / Resources

| SECURITY BRANDS Edge E1 Smart Keypad [pdf] User Guide
27-210, 27-215, Edge E1 Smart Keypad, Edge E1, Smart Keypad, Keypad
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SECURITY BRANDS User Manuals

Related Manuals