The product is a range hood manufactured by JennAir. It is designed for residential use only. The range hood ensures proper ventilation in the kitchen by removing smoke, steam, and odors while cooking. It comes with various controls and features for efficient operation and has specific installation and care requirements to ensure safety and optimal performance.

Installation Requirements
Before installing the range hood, make sure you have the necessary tools and parts. The location requirements should also be considered to ensure proper ventilation. The range hood can be vented or non-vented, depending on your preference. Electrical requirements must be met to ensure safe and proper functioning.

Range Hood Use
Once the range hood is installed, you can use the controls and features to adjust the ventilation settings according to your needs. These controls and features allow you to control the fan speed, lighting, and other functions of the range hood.

Range Hood Care
To maintain the performance and longevity of the range hood, regular cleaning is necessary. Proper cleaning instructions are provided to ensure effective removal of grease, dirt, and other residues.

Product Usage Instructions

Safety Precautions
Ensure your safety and the safety of others by following these precautions:

  • Read and obey all safety messages provided in the manual and on the appliance.
  • Pay attention to the safety alert symbol, indicating potential hazards.
  • Take immediate action when encountering instructions labeled as DANGER.
  • Follow all instructions to avoid serious injury or harm.
  • Understand the potential hazards, reduce the chance of injury, and be aware of the consequences of not following instructions.

Installation
Follow these steps for proper installation:

  1. Gather all the necessary tools and parts.
  2. Ensure the range hood is installed in a suitable location according to the provided requirements.
  3. If venting is required, follow the venting instructions provided.
  4. Connect the range hood to the appropriate electrical supply as per the electrical requirements.

Range Hood Operation
To use the range hood:

  1. Familiarize yourself with the controls and features.
  2. Adjust the fan speed, lighting, and other functions according to your preference.

Cleaning and Maintenance
Regularly clean the range hood to ensure optimal performance:

  1. Follow the provided cleaning instructions for effective removal of grease, dirt, and residues.

If you require any assistance or service, refer to the appropriate section in the manual. In the U.S.A., contact 1-800-JENNAIR (1-800-536-6247) or visit www.jennair.com. In Canada, call 1-800-JENNAIR (1-800-536-6247) or visit www.jennair.ca.

Installation Instructions and Use & Care Guide

For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call: 1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.ca.

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.

RANGE HOOD SAFETY

Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

  • This is the safety alert symbol.
  • This symbol alerts you to potential hazards that can kill or hurt you and others.
  • All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:
  • DANGER You can be killed or seriously injured if you don’t immediately follow instructions.
  • WARNING You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS. OBSERVE THE FOLLOWING:

  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
  • Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. m Ducted fans must always be vented to the outdoors.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.

CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

  • Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. • Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
  • Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
  • Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING”:

  • SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
  • NEVER PICK UP A FLAMING PAN – You may be burned.
  • DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
  • Use an extinguisher ONLY if:
    • You know you have a Class ABC extinguisher, and you already know how to operate it.
    • The fire is small and contained in the area where it started.
    • The fire department is being called.
    • You can fight the fire with your back to an exit. “Based on “Kitchen Fire Safety Tips” published by NFPA.
  • WARNING: To Reduce The Risk Of Fire Or Electric Shock. Do Not Use This Fan With Any Solid-State Speed Control Device.
  • This appliance is not intended for use by people (including children) whose physical, sensory or mental capacities are different or impaired or who lack the necessary experience or knowledge/expertise to do so, unless such persons are supervised or are trained to operate the appliance by a person who accepts responsibility for their safety.

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION REQUIREMENTS

Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools Needed

  • Level
  • Drill with 1¼” (3 cm), 3/8″ (9.5 mm) and 5/16″ (7.9 mm) drill bits
  • pencil
  • Wire stripper or utility knife
  • Tape measure or ruler
  • Pliers
  • Caulking gun and weatherproof caulking compound
  • Vent clamps
  • Jigsaw or keyhole saw
  • Flat-blade screwdriver
  • Metal snips
  • Phillips screwdriver

Parts Needed

  • Home power supply cable
  • 1/2″ (12.7 mm) UL listed or CSA approved strain relief
  • 3 UL listed wire connectors

For Vented Installations, you will also need:

  • 1 wall or roof cap
  • Metal vent system

For Non-Vented (Recirculating) Installations, you will also need:

  • Recirculation Kit for non-vented (recirculating) installations only. See “Assistance or Service” section to order.
  • 6″ (15.2 cm) diameter round metal vent duct – length required is determined by ceiling height.

Parts supplied
Remove parts from packages. Check that all parts are included.

  • Hood canopy assembly with ventilator and LED lights installed
  • Vent transition with back draft dampers
  • Metal grease filter – depending on model and size
  • Vent cover support bracket
  • Mounting template
  • 2-piece vent cover
  • 4 – 4.2 x 8 mm screws
  • 6 – 5 x 45 mm mounting screws
  • 2 – D6.4 x 18 mm washers
  • 2 – 8 x 40 mm wall anchors
  • 4 – 10 x 60 mm wall anchors
  • 4 – 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)
  • 2 – 3.5 x 9.5 mm sheet metal screws
  • T10 TORX®† adapter

Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer’s responsibility to comply with installation clearances specified on the model/serial/rating plate. The model/serial/ rating plate is located behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with a maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See “Electrical Requirements” section.
The canopy hood is factory-set for venting through the roof or wall. For non- vented (recirculating) installation see “For Non- Vented (Recirculating) Installation Only” in the “Connect Vent System” section. Recirculation Kit Part Number W10692908 is available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be installed must be sealed.

For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Product Dimensions

JENNAIR-W11244200B-30-and-36-InchWall-Mount-Canopy-Range-
Hood-1

Cabinet Dimensions

*For non-vented (recirculating) installations

IMPORTANT:

  • Minimum distance “X”: 24″ (61.0 cm) from electric cooking surface.
  • Minimum distance “X”: 27″ (68.6 cm) from gas cooking surfaces.
  • Suggested maximum distance “X”: 36″ (91.4 cm)

The chimneys can be adjusted for different ceiling heights. See the following chart.

*NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10272075 is available from your dealer or an authorized parts distributor. The chimney extension replaces the chimney shipped with the range hood.

Venting Requirements (vented models only)

  • Vent system must terminate to the outdoors, except for non-vented (recirculating) installations.
  • Do not terminate the vent system in an attic or other enclosed area.
  • Do not use 4″ (10.2 cm) laundry-type wall cap.
  • Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.
  • The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

  • Use no more than three 90° elbows.
  • Make sure there is a minimum of 24″ (61 cm) of straight vent between the elbows, if more than 1 elbow is used.
  • Do not install 2 elbows together.
  • Use clamps to seal all joints in the vent system.
  • The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood.
  • Use caulking to seal exterior wall or roof opening around the cap.
  • The size of the vent should be uniform.

Cold Weather Installations
An additional back draft damper should be installed to minimize backward cold airflow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air
Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Venting Methods
This canopy hood is factory-set for venting through the roof or wall.
A 6″ (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6″ (15.2 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

Rear discharge
A 90° elbow may be installed immediately above the hood.

For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, fitting a charcoal filter and the deflector. Fumes and vapors are recycled through the top grille.

JENNAIR-W11244200B-30-and-36-InchWall-Mount-Canopy-Range-
Hood-4

Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

The following example falls within the maximum recommended vent length of 35 ft (10.7 m).

  • 1 – 90° elbow = 5.0 ft (1.5 m)
  • 1 – wall cap = 0.0 ft (0.0 m)
  • 8 ft (2.4 m) straight = 8.0 ft (2.4 m)
  • Length of system = 13.0 ft (3.9 m)

Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575

  • A 120 V, 60 Hz, AC only, 15 A, fused electrical circuit is required.

  • If the house has aluminum wiring, follow the procedure below: Connect the aluminum wiring using special connectors and/or tools designed and UL listed for joining copper to aluminum.
    Follow the electrical connector manufacturer’s recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

  • Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial/rating plate. The model/serial/rating plate is located behind the left filter on the rear wall of the range hood.

  • Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

Prepare Location

  • It is recommended that the vent system be installed before hood is installed.
  • Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
  • Check your ceiling height and the hood height maximum before you select your hood.
  1. Disconnect power.

  2. Determine which venting method to use: roof, wall, or non vented.

  3.  Select a flat surface for assembling the range hood. Place covering over that surface.
    WARNING
    Excessive Weight Hazard
    Use two or more people to move and install range hood.
    Failure to do so can result in back or other injury.

  4. Using 2 or more people, lift range hood onto covered surface.

Range Hood Mounting Screws Installation

  1. Determine and mark the centerline on the wall where the canopy hood will be installed.

  2. Select a mounting height between a minimum of 24″ (61.0 cm) for an electric cooking surface, a minimum of 27″ (68.6 cm) for a gas cooking surface, and a suggested maximum of 36″ (91.4 cm) above the range to the bottom of the hood. Mark a reference line on the wall.

  3. Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall.

  4. Mark centers of the fastener locations through the template to the wall.
    IMPORTANT: All canopy mounting screws to be installed into wood where possible.

  5. If there is no wood to screw into, additional wall framing supports may be required or use the
    (4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws. Remove the template.

  6. For wood, drill 3/16″ (4.8 mm) pilot holes at all locations where screws are being installed into wood.

  7. For wall anchors, drill 7/16″ (10 mm) holes at all locations where wall anchors are being used.

  8. For wood, install the 2 – 5 x 45 mm mounting screws. Leave a 1/4″ (6.4 mm) gap between the wall and the back of the screw head to slide range hood into place.

  9. For wall anchors, install the 10 x 60 mm wall anchors and install the 5.4 x 75 mm screws into the wall anchors. Tighten until wall anchors are secure. Back the screws out 1/4″ (6.4 mm).

Vent Cover Bracket Installation

  1. Attach vent cover bracket to wall flush to the ceiling using 2 – 5 x 45 mm screws (use optional wall anchors if needed).

Complete Preparation

  1. Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the hood. See “Venting Requirements” section.

  2. Determine the required height for the home power supply cable and drill a 1¼” (3.2 cm) hole at this location.

  3. Run the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough 1/2″ conduit and wires from the fused disconnect (or circuit breaker) box to make the connection in the hood’s electrical terminal box.
    NOTE: Do not reconnect power until installation is complete.

  4. Use caulk to seal all openings.

Install In-Line Smart Kit – Optional
NOTE: Your range hood can work with either an internal or an inline (external) blower motor system. An optional In-Line Smart Kit (purchased separately) allows the blower motor that comes with this range hood to be installed in a location other than inside the range hood cavity.

CAUTION: To reduce the risk of fire and electric shock, install this range hood only with the In-Line Smart Kit manufactured by Whirlpool, Part Number W10692945.
For installation see the In-Line Smart Kit installation instructions. See the “Assistance or Service” section to order.

Install Range Hood

  1. 1. Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood.
    JENNAIR-W11244200B-30-and-36-InchWall-Mount-Canopy-Range-
Hood-9

  2. Remove the grease filter. See “Range Hood Care” section.

  3. Level the range hood and tighten upper mounting screws.

  4. Install 2 – 5 x 45 mm lower mounting screws and 2 – D6.4 x 18 mm washers and tighten (use optional wall anchors if needed).

Connect Vent System

  1. Install transition on top of hood (if removed for shipping) with 2 – 3.5 x 9.5 mm sheet metal screws.

For Vented Installations Only:

  1. Fit vent system over transition piece.
  2. Seal connection with clamps.
  3. Check that back draft dampers work properly.

For Non-Vented (Recirculating) Installations Only:

  1. Assemble the air deflector with the duct cover bracket with 4 assembly screws provided with the Recirculation Kit.

  2. Measure from the bottom of the air deflector to the bottom of the hood outlet.

  3. Cut the duct to the measured size “X”.

  4. Remove the air deflector.

  5. Slide the duct onto the bottom of the air deflector.

  6. Place the assembled air deflector and duct over the exhaust outlet from the hood.

  7. Reassemble the air deflector to the duct cover bracket using 4 assembly screws.

  8. Seal connections with vent clamps.

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.

  1. Disconnect power.

  2. Remove terminal box cover.

  3. Remove the knockout in the terminal box and install a UL listed or CSA approved 1/2″ (12.7 mm) strain relief.
    JENNAIR-W11244200B-30-and-36-InchWall-Mount-Canopy-Range-
Hood-14

  4. Run home power supply cable through strain relief, into terminal box.

  5. Use UL listed wire connectors and connect black wires (C) together.

  6. Use UL listed wire connectors and connect white wires (E) together.
    WARNING
    Electrical Shock Hazard
    Electrically ground blower.
    Connect ground wire to green and yellow ground wire in terminal box.
    Failure to do so can result in death or electrical shock.

  7. Connect green (or bare) ground wire from home power supply to yellow-green ground wire (F) in terminal box using UL listed wire connectors.

  8. Tighten strain relief screw.

  9. Install terminal box cover.

  10. Check that all light bulbs are secure in their sockets.

  11. Reconnect power.

Optional Power Cord Kit Installations
For optional power cord kit installations, follow the instructions supplied with the power cord kit. See the “Assistance or Service” section for information on ordering.
NOTE: Use only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood.

Install Vent Covers
When using both upper and lower vent covers, push lower cover down onto hood and lift upper cover to ceiling and install with two 4.2 x 8 mm screws.
NOTE: For vented installations, the upper vent cover may be reversed to hide slots.

Secure the bottom of the duct with 2 – 4.2 x 8 mm screws.

Complete Installation

  1. For non-vented (recirculating) installations only, install charcoal filters over grille on blower housing. See the “Range Hood Care” section.
  2. Install metal filters. See the “Range Hood Care” section.
  3. Check the operation of the range hood blower and light. See the “Range Hood Use” section.
    NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.

RANGE HOOD USE

The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen.
The range hood controls are located on the front side of the canopy.

JENNAIR-W11244200B-30-and-36-InchWall-Mount-Canopy-Range-
Hood-18

Control Panel

Controls and Features

NOTES:

  • To activate the controls, press and release the desired button.
  • The control feature button will be lit when a control feature is turned On.

Sleep Mode
The range hood automatically enters Sleep Mode when not in use. After 10 minutes of no range hood activity, all of the control button lights will turn Off. To deactivate Sleep Mode, press any button.

Auto Sense
Auto Sense allows the range hood fan to turn on automatically when it senses heat higher than its allowable temperature limit. When Auto Sense is On, the fan speed will increase or decrease based on the temperature Auto Sense is measuring.
Auto Sense can be manually increased by pressing a higher fan speed. The fan will run at the selected speed for 10 minutes before returning to the speed selected for Auto Sense.
If Auto Sense is On, the Auto button light will turn Off and go into Sleep Mode when the vent hood is not in use. If the vent hood is turned On by the consumer or by Auto Sense, the Auto button light will turn On.

To set Auto Sense:
Press AUTO.

To Select Auto Sense Cooktop Type:
NOTE:
The range hood is factory-set for the gas cooktop mode.
Press and hold AUTO for 5 seconds to switch between the gas cooktop and electric cooktop modes.
The Auto button light will flash 5 times when the range hood is changed to the electric cooktop mode. Auto Sense is now set to work with electric cooktops and ranges.
The Auto button light will flash 3 times when the range hood is changed to the gas cooktop mode. Auto Sense is now set to work with gas cooktops and ranges.
Changing the cooktop type will change the temperature limit for Auto Sense to turn On. When the range hood senses a high enough temperature, the fan will start automatically. When the temperature drops below the set temperature limit, the fan will stop automatically. The Auto button light will turn Off after the range hood enters Sleep Mode, but Auto Sense is still active.

To Deactivate Auto Sense:
If the Auto button is lit, press AUTO once to deactivate Auto Sense. The Auto button light will turn Off.
If Auto Sense is in Sleep Mode, press AUTO once to deactivate Sleep Mode and turn on the Auto button light. Press AUTO again to deactivate Auto Sense and turn Off the Auto button light.
Auto Sense will turn off automatically after 2 hours of no activation of the Auto Sense system. To reset Auto Sense, press AUTO.

Manual Vent Functions

Fan Speeds

  • Low
    Press LOW to turn the fan on at Low speed.

  • Med
    Press MED to turn the fan on at Medium speed.

  • Hi
    Press HI to turn the fan on at High speed.

  • Boost
    Press BOOST to turn the fan on at the highest speed. Boost will automatically turn Off after 10 minutes and the fan will switch to High speed.

Timer
The range hood can be set to turn off automatically after 15 minutes.

  1. Press and hold the desired fan speed button for 2 seconds. The fan will run on the chosen speed for 15 minutes and the fan speed button light will flash continuously.
    After 15 minutes, the fan will turn Off automatically.

  2.  Press the desired fan speed button again while the fan timer is running to cancel the fan timer.
    NOTE: Changing the fan speed or turning Auto Sense On will also cancel the 15-minute timer.

Light
The range hood has both task and ambient lighting.

To operate the lights:

  1. Touch LIGHT once to turn the LED task lights On.
  2. Touch LIGHT again to turn LED task lights Off. The ambient lights will turn On.
  3. Touch LIGHT a third time to turn the ambient lights Off.

NOTE: To turn both the task and ambient lights on at the same time, touch and hold LIGHT for 2 seconds. Touch LIGHT again to turn the task and ambient lights Off.

RANGE HOOD CARE

Cleaning
IMPORTANT: Clean the hood and grease filters frequently according to the following instructions. Replace grease filters before operating hood.

Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool or soap-filled scouring pads.
Always wipe dry to avoid water marks.

Cleaning Method:

  • Liquid detergent soap and water, or all-purpose cleanser
  • Wipe with damp soft cloth or nonabrasive sponge, and then rinse with clean water and wipe dry.

Metal Grease Filter

  1. Open the stainless steel panel. Grasp panel at the front corners and pull down to disengage the 2 catch pins from the spring catches. The panel is attached at the rear and will rotate down.

  2. Remove each filter by pulling the spring release handle and then pulling down the filter.

  3. Wash metal filters as needed in dishwasher or hot detergent solution.

  4. Reinstall the filter by making sure the spring release handles are toward the front. Insert aluminum filter into upper track.

  5. Push in spring release handle.

  6. Push up on metal filter and release handle to latch into place.

  7. Repeat steps 1 through 5 for the other filter.

  8. Close the stainless steel panel. Engage the (2) pins in the spring catches to secure.

Non-Vented (Recirculating) Installation Filters
The charcoal filter is not washable. It should last up to 6 months with normal use. Replace with Charcoal Filter Kit. See the
“Accessories” section for information on ordering.

To replace charcoal filter:

  1. Remove metal grease filter from range hood. See “Metal Grease Filter” in this section.

  2. Bend spring clips away from metal grease filter.

  3. Place charcoal filter into top side of metal filter.

  4. Bend spring clips back into place to secure the charcoal filter to the metal filter.

  5. Replace metal grease filter. See “Metal Grease Filter” in this section.

  6. Turn the charcoal filter clockwise to lock it.
    NOTE: When used in recirculation mode, to reduce the risk of fire and shock use only conversion kit model W10692910.

  7. Repeat steps 1 and 2 on the other filter.

Replacing an LED Lamp
The LED lights are replaceable by a service technician only. See the Warranty for service contact information.

WIRING DIAGRAM

JENNAIR-W11244200B-30-and-36-InchWall-Mount-Canopy-Range-
Hood-24 JENNAIR-
W11244200B-30-and-36-InchWall-Mount-Canopy-Range-Hood-25

ASSISTANCE OR SERVICE

If you need service
Please refer to the warranty.

If you need replacement parts
If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance.
To locate factory specified replacement parts in your area, call the following customer assistance telephone number or your nearest designated service center.

In the U.S.A.
Call JennAir Customer eXperience Center toll free:
1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.

Our consultants provide assistance with:

  • Scheduling of service. JennAir® appliances designated service technicians are trained to fulfill the product warranty and provide after-warranty service anywhere in the United States.
  • Features and specifications on our full line of appliances.
  • Referrals to local JennAir® appliance dealers.
  • Installation information.
  • Use and maintenance procedures.
  • Accessory and repair parts sales.
  • Specialized customer assistance (Spanish speaking, hearing impaired, limited vision, etc.).

For further assistance
If you need further assistance, you can write to JennAir® Appliances with any questions or concerns at:
JennAir Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor, MI 49022-2692
Please include a daytime phone number in your correspondence.

In Canada
Call the Whirlpool Canada LP Customer eXperience Centre toll free at 1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.ca.
Our consultants provide assistance with:-

  • Scheduling of service. JennAir® appliances designated service technicians are trained to fulfill the product warranty and provide after-warranty service anywhere in Canada.
  • Features and specifications on our full line of appliances.
  • Referrals to local JennAir® appliance dealers.
  • Installation information.
  • Use and maintenance procedures.
  • Accessory and repair parts sales.

For further assistance:
If you need further assistance, you can write to JennAir® Appliances with any questions or concerns at:
JennAir Brand Home Appliances Customer eXperience Centre 200 – 6750 Century Ave. Mississauga, Ontario L5N 0B7
Please include a daytime phone number in your correspondence.

Accessories

Charcoal Filter Kit
(for non-vented installations only) Order Part Number W10692910
Recirculation Kit
(for non-vented installations only) Order Part Number W10692908
Chimney Extension Kit Order Part Number EXTKIT12ES
6″ (15.2 cm) Makeup Air Kit
(consult local building codes) Order Part Number W10446915
Power Cord Kit
Order Part Number W10613691
In-Line Smart Kit
Order Part Number W10692945

®/™ ©2018 JennAir. All rights reserved. Used under license in Canada.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals